Carrier overflow in InGaN/GaN light-emitting diodes investigated by temperature-dependent short-circuit current characteristics

Author(s):  
Dong-Kuk Youn ◽  
Gyeong Won Lee ◽  
Jong-In Shim ◽  
Dong-Soo Shin
Nanomaterials ◽  
2018 ◽  
Vol 8 (7) ◽  
pp. 543 ◽  
Author(s):  
Moonsang Lee ◽  
Hyunkyu Lee ◽  
Keun Song ◽  
Jaekyun Kim

We report forward tunneling characteristics of InGaN/GaN blue light emitting diodes (LEDs) on freestanding GaN detached from a Si substrate using temperature-dependent current–voltage (T-I-V) measurements. T-I-V analysis revealed that the conduction mechanism of InGaN/GaN LEDs using the homoepitaxial substrate can be distinguished by tunneling, diffusion and recombination current, and series resistance regimes. Their improved crystal quality, inherited from the nature of homoepitaxy, resulted in suppression of forward leakage current. It was also found that the tunneling via heavy holes in InGaN/GaN LEDs using the homoepitaxial substrate can be the main transport mechanism under low forward bias, consequentially leading to the improved forward leakage current characteristics.


2014 ◽  
Vol 50 (11) ◽  
pp. 911-920 ◽  
Author(s):  
Ilya E. Titkov ◽  
Sergey Yu. Karpov ◽  
Amit Yadav ◽  
Vera L. Zerova ◽  
Modestas Zulonas ◽  
...  

2021 ◽  
Vol 39 (5A) ◽  
pp. 723-737
Author(s):  
Yamur M. Obied ◽  
Thamir M. Abdul Wahhab

The coordination between protective devices is the process of determining the most appropriate timing of power interruption during abnormal conditions in the power system. The aim of this work is to coordinate the protection of the 33/11 kV power distribution substation in Iraq using the CYME 7.1 software package. In this paper overcurrent and earth fault relays are simulated in two cases, with time delay setting and instantaneous setting, to obtain the Time Current Characteristics (TCC) curves for each Circuit Breaker (CB) relay of Al-Karama substation (2×31.5 MVA, 33/11 kV) in Babil distribution network. The short circuit current at each CB is calculated and accordingly, the protection coordination for Al-Karama substation has been simulated. The TCC curves have been obtained in two cases for overcurrent and earth fault relays; in a case with time delay setting and in the case with the instantaneous setting. The setting takes into consideration the short circuit current at the furthest point of the longest outgoing feeder and the shortest outgoing feeder.


2013 ◽  
Vol 22 (4) ◽  
pp. 047805 ◽  
Author(s):  
Rong Jiang ◽  
Hai Lu ◽  
Dun-Jun Chen ◽  
Fang-Fang Ren ◽  
Da-Wei Yan ◽  
...  

2012 ◽  
Vol 101 (25) ◽  
pp. 253512 ◽  
Author(s):  
Craig G. Moe ◽  
Gregory A. Garrett ◽  
Paul Rotella ◽  
Hongen Shen ◽  
Michael Wraback ◽  
...  

2016 ◽  
Vol 24 (11) ◽  
pp. 11594 ◽  
Author(s):  
Hongwei Wang ◽  
Yue Lin ◽  
Lihong Zhu ◽  
Yijun Lu ◽  
Yi Tu ◽  
...  

2010 ◽  
Vol 10 (5) ◽  
pp. 3304-3307
Author(s):  
Dong-Eun Kim ◽  
Gyu-Chae Choi ◽  
Jun-Woo Park ◽  
Byoung-Sang Kim ◽  
Burm-Jong Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document