Transformer Oil-Paper Insulation Aging Evaluation System Based on Different Aging Characteristics

Author(s):  
Zhao Chunming ◽  
Xu Wenxie ◽  
Deng Zhaohong
2021 ◽  
Vol 28 (6) ◽  
pp. 1867-1874
Author(s):  
Enze Zhang ◽  
Jiefeng Liu ◽  
Xianhao Fan ◽  
Yiyi Zhang ◽  
Chaohai Zhang

Transformer oil and oil-impregnated paper, serve as the essential parts of converter transformer, suffering various electric fields. The accumulation of surface charge on the paper would lead to flashover. When the power flow of the HVDC system is reversed, the charge field will easily lead to discharge. Direct-fluorination is a method which could affect the material property without alternating the bulk property. Besides, a new type of nano-modified transformer oil is a method to improve properties. This chapter presents a study of the effect of fluorination on surface charge behavior, the effect of polarity reversal voltages on interface charge behavior and the effect of Boron nitride (BN) nanoparticles on the high thermal conductivity of transformer oil. Results show that fluorination had an influence on the chemical property of the paper and BN nanoparticles has improvements in heat transfer process. In the polarity reversal test, the dissipation rate becomes smaller as the reversal time gets longer.


Energies ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 6491
Author(s):  
Qian Wu ◽  
Yizhuo Hu ◽  
Ming Dong ◽  
Bo Song ◽  
Changjie Xia ◽  
...  

Frequency response analysis is widely used to diagnose transformer winding deformation faults due to its high sensitivity, strong anti-interference capability, and equipment portability, but the results of frequency response analysis can be affected by insulation aging and moisture in the transformer, leading to errors in the diagnosis of winding deformation faults. Currently, there is no effective method to prevent such errors. This paper focuses on optimizing the criterion for diagnosing winding deformations when insulation aging and moisture are present. First, the winding frequency response curves of oil-paper insulation were determined by combining insulation aging and moisture tests of the oil-paper insulation with frequency response simulations of the transformer winding. Next, the winding deformation criterion predicting the likelihood and extent of errors diagnosing transformer winding deformations due to the insulation aging and moisture content is discussed. Finally, the corresponding criterion optimization method is proposed. The corresponding results show that insulation aging and moisture can lead to errors when using the correlation coefficient R criterion to diagnose the transformer winding deformations. Moreover, the possibility of winding deformation errors caused by the change of insulation state can be reduced by introducing the corresponding auxiliary criterion through comparing the capacitance change rate based on the frequency response method and that based on the dielectric spectrum method.


Sign in / Sign up

Export Citation Format

Share Document