A versatile inductive-link three-phase converter topology

Author(s):  
Khalegh Mozaffari ◽  
Mahshid Amirabadi
2021 ◽  
Vol 11 (3) ◽  
pp. 1322
Author(s):  
Dariusz Zieliński ◽  
Karol Fatyga

This paper proposes a control algorithm for a hybrid power electronic AC/DC converter for prosumer applications operating under deep phase current asymmetry. The proposed system allows independent control of active and reactive power for each phase of the power converter without current pulsation on the DC link connected to an energy store. The system and its algorithm are based on a three-phase converter in four-wire topology (AC/DC 3p-4w) with two dual-active bridge (DC/DC) converters, interfaced with a supercapacitor and an energy storage. The control algorithm tests were carried out in a Hardware in the Loop environment. Obtained results indicate that operation with deep unbalances and powers of opposite signs in individual phases leads to current oscillations in the DC link. This phenomenon significantly limits energy storage utilization due to safety and durability reasons. The proposed algorithm significantly reduces the level of pulsation in the DC link which increases safety and reduces strain on lithium-ion storage technology, enabling their application in four-wire converter applications.


2006 ◽  
Vol 21 (6) ◽  
pp. 1628-1636 ◽  
Author(s):  
Ricardo Quadros Machado ◽  
Simone Buso ◽  
Jos Antenor Pomilio

1975 ◽  
Vol IECI-22 (4) ◽  
pp. 519-522 ◽  
Author(s):  
K. Sankara Rao ◽  
M. N. S. Swamy ◽  
V. Rajagopalan

2005 ◽  
Vol 18 (3) ◽  
pp. 453-465 ◽  
Author(s):  
Zeljko Grbo ◽  
Slobodan Vukosavic ◽  
Emil Levi

Although apparently simpler, the SRM drives are nowadays more expensive than their conventional AC drive counterparts. This is to a great extent caused by the lack of a standardised power electronic converter for SRM drives, which would be available on the market as a single module. A number of attempts were therefore made in recent times to develop novel power electronic converter structures for SRM drives, based on the utilization of a three-phase voltage source inverter (VSI), which is readily available as a single module. This paper follows this line of thought and presents a novel power electronic converter topology for SRM drives, which is entirely based on utilization of standard inverter legs. One of its most important feature is that both magnetizing and demagnetizing voltage may reach the DC-bus voltage level while being contemporarily applied during the conduction overlap in the SRM adjacent phases. At the same time, the voltage stress across the power switches equals the DC-bus voltage. The topology is functional in all operating regimes of the drive. Principle of operation is explained in detail for a three-phase SRM drive and experimental results obtained with a 6/4 switched reluctance motor, are included. Four inverter legs are required in this case. Some considerations, justifying the proposed converter topology from the point of view of the cost, are included.


Author(s):  
Mohammad Rustam M. L. ◽  
F. Danang Wijaya

Under various external conditions, grid connected PV system performance is strongly affected by the topology that is used to connect a PV system with grid. This research aims to design a multistring based converter topology for three-phase grid connected 200 kW PV system that has a high performance in various operating conditions. Research was done by a simulation method using Matlab-Simulink with performance being evaluated including the generated power, efficiency, power quality in accordance with grid requirements, as well as the power flow. In the simulation, multistring converter topology was designed using two dc-dc boost multistring converters connected in parallel to a centralized of three-phase three-level NPC inverter with the size of the string being shorter and more parallel strings as well as the maximum voltage of the PV array of 273.5 V close to dc voltage reference of 500 V. Each dc-dc boost multistring converter have individual MPPT controllers. The simulation results showed that this multistring converter topology had a high performance in various operating conditions. This due to more power generated by the NPC inverter (> 190 kW) at the time of high power generation on the STC conditions (1000 W/m2, 25 oC), the lowest efficiency of the total system is 95.08 % and the highest efficiency of the total system is 99.4 %, the quality of the power generated in accordance with the requirements of grid, as well as the inverter put more active power to the grid and less reactive power to the grid. The response of the inverter slightly worse for loads with greater reactive power and unbalanced.