Evaluation of predictive methods of acoustic comfort parameters in university classrooms

Author(s):  
Paolo Croce ◽  
Francesco Leccese ◽  
Paulo Henrique Trombetta Zannin
2018 ◽  
Vol 32 ◽  
pp. 01002
Author(s):  
Alexandra Ene ◽  
Tiberiu Catalina ◽  
Andreea Vartires

Thermal and acoustic comfort, inside a vehicle’s cabin, are highly interconnected and can greatly influence the health of the passengers. On one hand, the H.V.A.C. system brings the interior air parameters to a comfortable value while on the other hand, it is the main source of noise. It is an intriguing task to find a balance between the two. In this paper, several types of air diffusers were used in order to optimize the ratio between thermal and acoustic interior comfort. Using complex measurements of noise and thermal comfort parameters we have determined for each type of air diffuser the sound pressure level and its impact on air temperature and air velocity.


2019 ◽  
Vol 29 (6) ◽  
pp. 851-859 ◽  
Author(s):  
Michael Fabozzi ◽  
Alessandro Dama

Maintaining a satisfactory thermal environment is of primary importance, especially when the goal is to maximize learning such as in schools or universities. This paper presents a field study conducted in Milan during summer 2017 in 16 classrooms of Politecnico di Milano, including both naturally ventilated (NV) and air-conditioned (AC) environments. This study asked 985 students to report their thermal perception and their responses were evaluated according to the measured thermal comfort parameters to assess the prediction as given by Fanger and adaptive models, according to ANSI/ASHRAE 55-2017 and EN 15251:2007 standards. Furthermore, an analysis regarding potential effects of gender in comfort perception was performed. The results confirmed the fitness of Fanger’s model for the prediction of occupants’ thermal sensations in AC classrooms with a reasonable accuracy. In NV classrooms, the Adaptive model was proven to be suitable for predicting students’ comfort zone according to ASHRAE 55 Standard, while the adaptive comfort temperatures recommended by EN 15251 were not acceptable for a large number of students. No significant differences in thermal comfort perception between genders have been observed, except for two NV classrooms in which females’ thermal sensation votes had resulted closer to neutrality in comparison to males, who expressed a warmer thermal sensation.


2017 ◽  
Vol 115 ◽  
pp. 166-172 ◽  
Author(s):  
Xi Chen ◽  
Jian Kang
Keyword(s):  

Author(s):  
Laurentiu Predescu ◽  
Daniel Dunea

Optical monitors have proven their versatility into the studies of air quality in the workplace and indoor environments. The current study aimed to perform a screening of the indoor environment regarding the presence of various fractions of particulate matter (PM) and the specific thermal microclimate in a classroom occupied with students in March 2019 (before COVID-19 pandemic) and in March 2021 (during pandemic) at Valahia University Campus, Targoviste, Romania. The objectives were to assess the potential exposure of students and academic personnel to PM and to observe the performances of various sensors and monitors (particle counter, PM monitors, and indoor microclimate sensors). PM1 ranged between 29 and 41 μg m−3 and PM10 ranged between 30 and 42 μg m−3. It was observed that the particles belonged mostly to fine and submicrometric fractions in acceptable thermal environments according to the PPD and PMV indices. The particle counter recorded preponderantly 0.3, 0.5, and 1.0 micron categories. The average acute dose rate was estimated as 6.58 × 10−4 mg/kg-day (CV = 14.3%) for the 20–40 years range. Wearing masks may influence the indoor microclimate and PM levels but additional experiments should be performed at a finer scale.


2021 ◽  
Vol 738 (1) ◽  
pp. 012039
Author(s):  
N. Aldona ◽  
D. Seftyarizki ◽  
A. Prihatiningrum ◽  
P. A. Ramawangsa ◽  
E. Khairunnisa ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document