Study on Peaking Ability and Operation Safety of Thermal Power Unit in Peak Load Regulation of Power System

Author(s):  
Xuhui Zhang ◽  
Xingsen Yang ◽  
Haichao Wang ◽  
Ke Liu ◽  
Fuxing Cui ◽  
...  
2015 ◽  
Vol 8 (1) ◽  
pp. 86-92 ◽  
Author(s):  
Wei Zhang ◽  
Chao Qin ◽  
Bingbing Zhou ◽  
Yanli Huang ◽  
Zhongfu Tan

Providing peaking auxiliary for wind power will affect the thermal power generation efficiency and reduce generation economic benefit. To realize the coordinated scheduling optimization of thermal power and wind power, the key problem is the economic compensation of thermal power peaking. In this paper, through the analysis of the influence of wind power on thermal power generation performance and thermal power peak load regulation on abandon wind, an economic compensation model based on objective optimization is established. The example analysis shows that cooperation of thermal power and wind power can improve the wind power accommodation level and unit efficiency, and the economic compensation mechanism can guarantee thermal power unit economic benefit effectively.


2014 ◽  
Vol 986-987 ◽  
pp. 404-411
Author(s):  
Qi Yang ◽  
Xin Zeng ◽  
Qing Kui Guo ◽  
Yong Yu Yuan ◽  
Jian Jun Sun ◽  
...  

Through the summary of typical accident, the problem between the over speed protection device of thermal power unit steam turbine and over frequency generator tripping measure is analyzed in island operation of sending ends of regional grid. The optimizing allocation principle between over frequency generator tripping measure and over speed protection equipment is put forward. By a variety of program analysis and comparison, the optimizing scheme is given. Finally, the typical models of thermal power unit steam turbine over speed protection are established in software. Based on a practical power system as an example, the whole process of islanding is simulated. Checking the coordination with existing over frequency generator tripping measure and the relay setting related to power network in the islanding operation, the validity and practicability of the optimal scheme and principle are analyzed. With the method, the regional grid will remain safe and stable.


2020 ◽  
Vol 143 ◽  
pp. 02047
Author(s):  
Shufang Tang ◽  
Guoan Tang ◽  
Xiaohong He ◽  
Lijun Zheng ◽  
Cong Yu ◽  
...  

This paper introduces the retrofit scheme of the New Condensing Extraction Backpressure heating technology, and the technology is recommend for use by comparing and analysing the combined heat and power system based on a 330MW unit retrofit. After improvement, the heating capacity has been Obvious improved, the generation power has been greatly reduced and the capacity of peak load regulation has been significantly improved, which can not only realize the thermoelectric decoupling, but also obtain the remarkable economic benefit.


2014 ◽  
Vol 986-987 ◽  
pp. 465-469 ◽  
Author(s):  
Gang Wang ◽  
Xiao Dong Ma ◽  
Chao Wang ◽  
Peng Ye

Base on Nuclear Power Plant (NPP) participating in peak load regulation of power grid, this paper studies the operation mode of hydropower, thermal power and NPP in Combined Peak Load Regulation. The optimization model for Peaking depth of NPP was set up. The case based on actual power grid were calculated and analyzed, results of the research show that in combined peak load regulation of hydropower, thermal power and NPP, a reasonable peaking depth of NPP will effectively alleviate the peaking pressure of power grid, avoid start-stop of thermal power and abandoned water of hydropower, while ensuring the hydroelectric generating capacity in the low load periods, and ensure thermal power output smooth, it further reduce the operating costs, verify the effectiveness of the model.


2013 ◽  
Vol 416-417 ◽  
pp. 2110-2113
Author(s):  
Xing Liu

This paper, focusing on the practical moving condition of the thermal power plants, studied in detail that how to did the curve fitting according to the units data collected from Tianjin Dagang Power Plant; studied the each fuel loss in the process of start-stop the units and their calculation methods; and put forward that fuel consumption and life expenditure while starting and stopping the units should be considered when using peak-load regulation; worked out the GA program and proved GAs accuracy and superiority through the calculation examples, and showed that GA had great practical and research meaning.


2014 ◽  
Vol 986-987 ◽  
pp. 196-201 ◽  
Author(s):  
Tao Zhang ◽  
Xiao Dong Ma ◽  
Yu Zhu ◽  
Gang Wang ◽  
Peng Ye

Based on extensive research, introduced the peak load regulation characteristics and capacity of different nuclear power plant (NPP) in this paper. The running mode of NPP participating in peak load regulation of power system, combined operation tactics of NPP with other peaking power source and synergistic scheduling of an integrated power generation system with wind, photovoltaic, energy storage unit and NPP were summarized, technology development trend of NPP participating in peak load regulation of power system was analyzed and forecasted.


Sign in / Sign up

Export Citation Format

Share Document