Voltage stability margin improvement using shunt capacitors and active and reactive power management

Author(s):  
H. Omidi ◽  
B. Mozafari ◽  
A. Parastar ◽  
M.A. Khaburi
2016 ◽  
Vol 65 (1) ◽  
pp. 19-32 ◽  
Author(s):  
Mirosław Parol ◽  
Łukasz Rokicki

Abstract Low voltage microgrids are autonomous subsystems, in which generation, storage and power and electrical energy consumption appear. In the paper the main attention has been paid to the voltage stability issue in low voltage microgrid for different variants of its operation. In the introduction a notion of microgrid has been presented, and also the issue of influence of active and reactive power balance on node voltage level has been described. Then description of voltage stability issue has been presented. The conditions of voltage stability and indicators used to determine voltage stability margin in the microgrid have been described. Description of the low voltage test microgrid, as well as research methodology along with definition of considered variants of its operation have been presented further. The results of exemplary calculations carried out for the daily changes in node load of the active and reactive power, i.e. the voltage and the voltage stability margin indexes in nodes have been presented. Furthermore, the changes of voltage stability margin indexes depending on the variant of the microgrid operation have been presented. Summary and formulation of conclusions related to the issue of voltage stability in microgrids have been included at the end of the paper.


2021 ◽  
Author(s):  
Umang Patel

Power system stability is gaining importance because of unusual growth in power system. Day by day use of nonlinear load and other power electronics devices created distortions in the system which creates problems of voltage instability. Voltage stability of system is major concerns in power system stability. When a transmission network is operated near to their voltage stability limit it is difficult to control active-reactive power of the system. Our objectives are the analysis of voltage stability margin and active-reactive power control in proposed system which includes model of STATCOM with aim to analyse its behavior to improve voltage stability margin and active-reactive power control of the system under unbalanced condition. The study has been carried out using MATLAB Simulation program on three phase system connected to unbalanced three phase load via long transmission network and results of voltage and active-reactive power are presented. In future work, we can do power flow calculation of large power system network and find the weakest bus of the system and by placing STATCOM at that bus we can improve over all stability of the system


2017 ◽  
Vol 5 (10) ◽  
pp. 375-389
Author(s):  
K. Lenin

In this paper, Aeriform Nebula Algorithm (ANA) has been used for solving the optimal reactive power dispatch problem. Aeriform Nebula Algorithm (ANA) is stirred from the deeds of cloud. ANA imitate the creation behavior, modify behavior and expand deeds of cloud. The projected Aeriform Nebula Algorithm (ANA) has been tested on standard IEEE 30 bus test system and simulation results shows clearly about the superior performance of the proposed Aeriform Nebula Algorithm (ANA) in reducing the real power loss and voltage stability has been enhanced.


Sign in / Sign up

Export Citation Format

Share Document