Phase-resolved study on partial discharge for degradation diagnosis in polymeric insulating materials using model electrode system

Author(s):  
F. Komori ◽  
A. Kojima ◽  
M. Hikita ◽  
Y. Suzuoki ◽  
T. Mizutani
Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1065
Author(s):  
Houssem Eddine Nechmi ◽  
Michail Michelarakis ◽  
Abderrahmane (Manu) Haddad ◽  
Gordon Wilson

Negative and positive partial discharge inception voltages and breakdown measurements are reported in a needle-plane electrode system as a function of pressure under AC voltage for natural gases (N2, CO2, and O2/CO2), pure NovecTM gases (C4F7N and C5F10O) and NovecTM in different natural gas admixtures. For compressed 4% C4F7N–96% CO2 and 6% C5F10O–12% O2–82% CO2 gas mixtures, the positive-streamer mode is identified as the breakdown mechanism. Breakdown and negative partial discharge inception voltages of 6% C5F10O–12% O2–82% CO2 are higher than those of 4% C4F7N–96% CO2. At 8.8 bar abs, the breakdown voltage of 6% C5F10O–12% O2–82% CO2 is equal to that of 12.77% O2–87.23% CO2 (buffer gas). Synergism in negative partial discharge inception voltage/electric field fits with the mean value and the sum of each partial pressure individually component for a 20% C4F7N–80% CO2 and 6% C5F10O–12% O2–82% CO2, respectively. In 9% C4F7N–91% CO2, the comparison of partial discharge inception electric fields is Emax (CO2) = Emax(C4F7N), and Emax (12.77% O2–87.23% CO2) = Emax(C5F10O) in 19% C5F10O–81%(12.77% O2–87.23% CO2). Polarity reversal occurs under AC voltage when the breakdown polarity changes from negative to positive cycle. Polarity reversal electric field EPR was quantified. Fitting results show that EPR (CO2) = EPR(9% C4F7N–91% CO2) and EPR(SF6) = EPR (22% C4F7N–78% CO2). EPR (4% C4F7N–96% CO2) = EPR (12.77% O2–87.23% CO2) and EPR (6% C5F10O–12% O2–82% CO2) < EPR (4% C4F7N–96% CO2) < EPR (CO2).


Author(s):  
Tatsuki Okamoto ◽  
Hiroshi Suzuki ◽  
Naohiro Hozumi ◽  
Masaaki Ikeda

2014 ◽  
Vol 698 ◽  
pp. 615-620 ◽  
Author(s):  
Aleksandr Bychkov ◽  
Sergey Korobeynikov ◽  
Aleksandr Ovsyannikov

The results of the experimental studies of partial discharges in GK transformer oil with electrode system “point-plane” that provide sharp inhomogeneous electric field are presented. It was found out that two types of partial discharge pulses which differ in form and time duration appeared at the negative point polarity of the needle. The study of different types of pulses was conducted by electric and electro-optical methods of partial discharge registration.


Sign in / Sign up

Export Citation Format

Share Document