Measurement of Excess Current Accompanying Partial Discharge of Polymer Film in Tri-electrode system under Power Frequency Voltage

Author(s):  
Ran Duan ◽  
Ming Ren ◽  
Tianxin Zhuang
Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 1065
Author(s):  
Houssem Eddine Nechmi ◽  
Michail Michelarakis ◽  
Abderrahmane (Manu) Haddad ◽  
Gordon Wilson

Negative and positive partial discharge inception voltages and breakdown measurements are reported in a needle-plane electrode system as a function of pressure under AC voltage for natural gases (N2, CO2, and O2/CO2), pure NovecTM gases (C4F7N and C5F10O) and NovecTM in different natural gas admixtures. For compressed 4% C4F7N–96% CO2 and 6% C5F10O–12% O2–82% CO2 gas mixtures, the positive-streamer mode is identified as the breakdown mechanism. Breakdown and negative partial discharge inception voltages of 6% C5F10O–12% O2–82% CO2 are higher than those of 4% C4F7N–96% CO2. At 8.8 bar abs, the breakdown voltage of 6% C5F10O–12% O2–82% CO2 is equal to that of 12.77% O2–87.23% CO2 (buffer gas). Synergism in negative partial discharge inception voltage/electric field fits with the mean value and the sum of each partial pressure individually component for a 20% C4F7N–80% CO2 and 6% C5F10O–12% O2–82% CO2, respectively. In 9% C4F7N–91% CO2, the comparison of partial discharge inception electric fields is Emax (CO2) = Emax(C4F7N), and Emax (12.77% O2–87.23% CO2) = Emax(C5F10O) in 19% C5F10O–81%(12.77% O2–87.23% CO2). Polarity reversal occurs under AC voltage when the breakdown polarity changes from negative to positive cycle. Polarity reversal electric field EPR was quantified. Fitting results show that EPR (CO2) = EPR(9% C4F7N–91% CO2) and EPR(SF6) = EPR (22% C4F7N–78% CO2). EPR (4% C4F7N–96% CO2) = EPR (12.77% O2–87.23% CO2) and EPR (6% C5F10O–12% O2–82% CO2) < EPR (4% C4F7N–96% CO2) < EPR (CO2).


1983 ◽  
Vol 103 (4) ◽  
pp. 9-17 ◽  
Author(s):  
Kaoru Ishihara ◽  
Kenji Tsuge ◽  
Yukio Mizuno ◽  
Noriyuki Shimizu ◽  
Masamitsu Kosaki ◽  
...  

2014 ◽  
Vol 698 ◽  
pp. 615-620 ◽  
Author(s):  
Aleksandr Bychkov ◽  
Sergey Korobeynikov ◽  
Aleksandr Ovsyannikov

The results of the experimental studies of partial discharges in GK transformer oil with electrode system “point-plane” that provide sharp inhomogeneous electric field are presented. It was found out that two types of partial discharge pulses which differ in form and time duration appeared at the negative point polarity of the needle. The study of different types of pulses was conducted by electric and electro-optical methods of partial discharge registration.


2021 ◽  
Author(s):  
Xiajin Rao ◽  
Dajian Li ◽  
Xiaofei Xia ◽  
Yi Su ◽  
Yufeng Lu ◽  
...  

Abstract The greenhouse effect of SF6 increasingly limits its application in various gas insulated equipment. C6F12O combines the advantages of insulation resistance, safety and environmental protection. When mixed with buffer gas, C6F12O is considered to have potential application prospects in medium and low voltage equipment. In this paper, about the partial discharge characteristics of the mixed gas, an experimental study was carried out. The partial discharge initiation voltage and discharge extinction voltage of mixed gas under power frequency voltage are measured and compared with the breakdown voltage. The results show that with the increase of mixing ratio, the partial discharge initiation voltage and extinction voltage of mixed gas gradually increase, and the effect of gas pressure on high mixing ratio is obvious. The difference between the partial discharge inception voltage and the breakdown voltage is larger than that of pure N2. The research in this paper can provide an important reference for the application, operation and protection of C6F12O mixed gas in medium and low voltage equipment.