Design of high-efficiency bidirectional DC-DC converter and high-precision efficiency measurement

Author(s):  
Wensong Yu ◽  
Hao Qian ◽  
Jih-Sheng Lai
Symmetry ◽  
2021 ◽  
Vol 13 (3) ◽  
pp. 398
Author(s):  
Yaroslav S. Derbenev ◽  
Yury N. Filatov ◽  
Anatoliy M. Kondratenko ◽  
Mikhail A. Kondratenko ◽  
Vasiliy S. Morozov

We present a review of the possibilities to conduct experiments of high efficiency in the nuclear and high energy physics with spin-polarized beams in a collider complex, configuration of which includes Siberian snakes or figure-8 collider ring. Special attention is given to the recently elicited advantageous possibility to conduct high precision experiments in a regime of the spin transparency (ST) when the design global spin tune is close to zero. In this regime, the polarization control is realized by use of spin navigators (SN), which are compact special insertions of magnets dedicated to a high flexibility spin manipulation including frequent spin flips.


2012 ◽  
Vol 503-504 ◽  
pp. 764-767 ◽  
Author(s):  
Lin Zhu ◽  
Lin Pan

The super-thin rod cylindrical grinding is a problem in the machining, super-thin rod with large slenderness ratio, poor rigidity, large roundness error after grinding, and with low processing efficiency. This study uses cylindrical honing processing super-thin rod parts, and designing the super-thin rod cylindrical honing head, carrying on a honing test. The results show that the super-thin rod cylindrical coarse honing capacity reach up to 0.002mm/double stroke(length 1698mm), surface roughness reach up to Ra 0.8 ~ 0.025μm after honing, roundness error reach up to 2μm. It fully shows that super-thin rod cylindrical honing technology has high precision, low surface roughness, flexible production processing and high efficiency.


2011 ◽  
Vol 383-390 ◽  
pp. 5771-5777
Author(s):  
Yu Quan Ma ◽  
Li Hong Zhang ◽  
Shu Fen Han ◽  
Zhi Peng Lin

The constant voltage power supply with dual directional reversible PWM compensation has merits of high precision, high efficiency, small volume, and so on. To ensure the quality of supply, it is important to fix the value of inductance, capacitance in main circuit. From the angle of filtering, and through analysis of the circuit working, detailed formulas of the inductance and capacitance calculation are given and an example of it is given too. In parameters calculation, to reduce the volume, the filter inductance is taken a smaller value but the capacitance is taken a greater value; the DC smoothing capacitance should be chosen according to the amplitude limit of DC voltage rising in inversion, and should be taken as great as possible to maintain voltage stabilizing precision.


2013 ◽  
Vol 756-759 ◽  
pp. 574-578 ◽  
Author(s):  
Xue Zhe Li ◽  
Xiao Hui Feng

The gas sealing performance of electronic sphygmomanometer is an important index of its quality control. At present, the gas leak detection of sphygmomanometer is mainly by manual, which has disadvantages of low efficiency and precision, huge impact of human factors and so on. An automatic and high precision gas sealing performance inspection module is proposed in the paper, which solves the problems of pressure calibration and gas leak detection of sphygmomanometer products. The paper also introduces the principle and implementation of system project. The module is designed by STC12C5A single-chip, KPM DC air pump and the pressure sensor of E8CC, which has advantages of high precision, high efficiency, low cost, and flexible operation etc.


Sign in / Sign up

Export Citation Format

Share Document