A software package to standardise pulsatile in-vitro testing of prosthetic heart valves

Author(s):  
M. Grigioni ◽  
V. Barbaro ◽  
C. Daniele ◽  
A. Palombo
1973 ◽  
Vol 29 (03) ◽  
pp. 694-700 ◽  
Author(s):  
Paul L. Rifkin ◽  
Marjorie B. Zucker

SummaryDipyridamole (Persantin) is reported to prolong platelet survival and inhibit embolism in patients with prosthetic heart valves, but its mechanism of action is unknown. Fifty jxM dipyridamole failed to reduce the high percentage of platelets retained when heparinized human blood was passed through a glass bead column, but prolonged the inhibition of retention caused by disturbing blood in vitro. Possibly the prostheses act like disturbance. Although RA 233 was as effective as dipyridamole in inhibiting the return of retention, it was less effective in preventing the uptake of adenosine into erythrocytes, and more active in inhibiting ADP-induced aggregation and release. Thus there is no simple relation between these drug effects.


Author(s):  
Raimond Grimberg ◽  
Adriana Savin ◽  
Shiu C. Chan ◽  
Rozina Steigmann ◽  
Lalita Udpa ◽  
...  

Prosthetic heart valves of the Bjork-Shiley Convexo-Concave (BSCC) type have long been used extensively in implants; however, there have been reports of cases where one component of the valves failed, leading to the demise of the patient. This paper presents a new method for noninvasive electromagnetic evaluation for this type of valve, using an eddy current transducer with orthogonal coils. In vitro experiments have shown that discontinuities of outlet strut with depths equal or larger than 0.4mm can be detected with a probability of detection (POD) of 86.4%, and in the case of discontinuities with depth equal or larger than 0.6mm with POD of 97%.


Author(s):  
Martin Gottwik ◽  
S. Hartung ◽  
O. Epe ◽  
S. Langsdorf ◽  
J. Thormann ◽  
...  

1984 ◽  
Vol 106 (1) ◽  
pp. 83-88 ◽  
Author(s):  
T. Kitamura ◽  
T. Kijima ◽  
H. Akashi

This paper demonstrates a modeling technique of prosthetic heart valves. In the modeling, a pumping cycle is divided into four phases, in which the state of the valve and flow is different. The pressure-flow relation across the valve is formulated separately in each phase. This technique is developed to build a mathematical model used in the real time estimation of the hemodynamic state under artificial heart pumping. The model built by this technique is simple enough for saving the computational time in the real time estimation. The model is described by the first-order ordinary differential equation with 12 parameters. These parameters can be uniquely determined beforehand from in-vitro experimental data. It is shown that the model can adapt, with sufficient accuracy, to a change in the practical pumping condition and the viscosity of the fluid in their practical range, and is also demonstrated that the estimated backflow volume by model agrees closely with the actual one.


1998 ◽  
Vol 21 (9) ◽  
pp. 548-552 ◽  
Author(s):  
R. Paul ◽  
O. Marseille ◽  
E. Hintze ◽  
L. Huber ◽  
H. Schima ◽  
...  

Thromboembolic complications remain as one of the main problems for blood contacting artificial organs such as heart valves, bloodpumps and others. In vitro evaluation of thrombogenesis in prototypes has not previously been part of the standard evaluation of these devices. In comparison to hemolysis testing, evaluation of the thrombogenic potential is more difficult to perform because of the complexity of the blood coagulation system. We present an in vitro testing procedure that allows the accelerated examination of the thrombogenic potential of different types of blood pumps. Additionally, first results are presented that indicate the reliability of the accelerated clotting test for mechanical heart valves. Results for the centrifugal pump BioMedicus and two microaxial pumps have shown typical thrombus formation at locations such as bearings. The results indicate that the accelerated clotting test is an excellent addition to the much more expensive animal testing of artificial organs or assist devices. In vitro testing permits studies of thrombus formation to be performed at an early stage and at low costs and also facilitates a more precise investigation of device areas known to be potential hot spots for thrombus formation.


Author(s):  
M. A. Rezvova ◽  
E. A. Ovcharenko ◽  
P. A. Nikishev ◽  
S. V. Kostyuk ◽  
L. V. Antonova ◽  
...  

Implantation of polymeric heart valves can solve the problems of existing valve substitutes – mechanical and biological. Objective: to comprehensively assess the hemocompatibility of styrene-isobutylene-styrene (SIBS) triblock copolymer, synthesized by controlled cationic polymerization in comparison with expanded polytetrafluoroethylene (ePTFE) used in clinical practice. Materials and methods. SIBS-based films were made by polymer solution casting method; in vitro biocompatibility assessment was performed using cell cultures, determining cell viability, cell adhesion and proliferation; tendency of materials to calcify was determined through in vitro accelerated calcification; in vivo biocompatibility assessment was performed by subcutaneous implantation of rat samples; hemocompatibility was determined ex vivo by assessing the degree of hemolysis, aggregation, and platelet adhesion. Results. The molecular weight of synthesized polymer was 33,000 g/mol with a polydispersity index of 1.3. When studying cell adhesion, no significant differences (p = 0.20) between the properties of the SIBS polymer (588 cells/mm2) and the properties of culture plastics (732 cells/mm2) were discovered. Cell adhesion for the ePTFE material was 212 cells/mm2. Percentage of dead cells on SIBS and ePTFE samples was 4.40 and 4.72% (p = 0.93), respectively, for culture plastic – 1.16% (p < 0.05). Cell proliferation on the ePTFE surface (0.10%) was significantly lower (p < 0.05) than for the same parameters for SIBS and culture plastic (62.04 and 44.00%). Implantation results (60 days) showed the formation of fibrous capsules with average thicknesses of 42 μm (ePTFE) and 58 μm (SIBS). Calcium content in the explanted samples was 0.39 mg/g (SIBS), 1.25 mg/g (ePTFE) and 93.79 mg/g (GA-xenopericardium) (p < 0.05). Hemolysis level of red blood cells after contact with SIBS was 0.35%, ePTFE – 0.40%, which is below positive control (p < 0.05). Maximum platelet aggregation of intact platelet-rich blood plasma was 8.60%, in contact with SIBS polymer – 18.11%, with ePTFE – 22.74%. Conclusion. In terms of hemocompatibility properties, the investigated SIBS polymer is not inferior to ePTFE and can be used as a basis for development of polymeric prosthetic heart valves.