Comparing and evaluating the performance of SSSC with Fuzzy Logic controller and PI controller for transient stability enhancement

Author(s):  
B. Geethalakshmi ◽  
A. Saraswathi ◽  
P. Dananjayan
Author(s):  
S Arockiaraj ◽  
BV Manikandan

In transmission line, the series compensation is used to improve stability and increases the power transmission capacity. It generates sub synchronous resonance (SSR) at turbine-generator shaft due to the interaction between the series compensation and wind turbine system. To solve this, several methods have been presented. However, these provide less performance during contingency period. Therefore, to mitigate the SSR and also to improve the dynamic performance of hybrid wind and PV system connected with series compensated wind farms, the adaptive technique of the Black Widow Optimization algorithm based Fuzzy Logic Controller (BWO-FLC) with UPFC is proposed in this paper. Here, the objective function is solved optimally using BWO technique. Based on this, the Fuzzy Logic Controller is designed. The results proved that the proposed controller performs the mitigation of SSR. The damping ratios of proposed controller to mitigation of SSR are 0.0098, 0.0139, and 0.0195 for wind speed of 6, 8 and 10 m/s respectively.


Author(s):  
Rambir Singh ◽  
Asheesh K. Singh ◽  
Rakesh K. Arya

This paper examines the size reduction of the fuzzy rule base without compromising the control characteristics of a fuzzy logic controller (FLC). A 49-rule FLC is approximated by a 4-rule simplest FLC using compensating factors. This approximated 4-rule FLC is implemented to control the shunt active power filter (APF), which is used for harmonic mitigation in source current. The proposed control methodology is less complex and computationally efficient due to significant reduction in the size of rule base. As a result, computational time and memory requirement are also reduced significantly. The control performance and harmonic compensation capability of proposed approximated 4-rule FLC based shunt APF is compared with the conventional PI controller and 49-rule FLC under randomly varying nonlinear loads. The simulation results presented under transient and steady state conditions show that dynamic performance of approximated simplest FLC is better than conventional PI controller and comparable with 49-rule FLC, while maintaining harmonic compensation within limits. Due to its effectiveness and reduced complexity, the proposed approximation methodology emerges out to be a suitable alternative for large rule FLC.


Author(s):  
Anurag Singh Tomer ◽  
Saty Prakash Dubey

<p>This Paper gives a complete modeling and simulation of a two inverter fed six phase permanent magnet synchronous motor drive system, Then response based comparative analysis is done on starting torque ,settling time, Steady state current at various speed levels and torque levels by changing  proportional- integral (PI) controller to  Fuzzy logic controller. The PI controller has some disadvantages like, more settling time, sluggish response due to sudden change in load torque etc. So an intelligent controller, based on fuzzy logic is introduced which replaces the PI-controller and its drawbacks. The performance of both the controller has been investigated and studied by comparing the different plots obtained by setting various speed level both incremented and decremented speed  , at different load conditions like No-load, fix load and dynamic load through Matlab/Simulink environment. Finally it is concluded from the result that fuzzy logic based controller is robust, reliable gives quick response with high starting torque and more effective than the conventional PI controller. It is also observed that both the proposed model can also run above rated speed significantally.</p>


2018 ◽  
Vol 17 (1) ◽  
pp. 107
Author(s):  
Gusti Made Ngurah Christy Aryanata ◽  
I Nengah Suweden ◽  
I Made Mataram

A good electrical power system is a system that can serve the load in a sustainable and stable voltage and frequency. Changes in frequency occur due to the demand of loads that change from time to time. The frequency setting of the PLTG power system depends on the active power charge in the system. This active power setting is done by adjusting the magnitude of the generator drive coupling. The frequency setting is done by increasing and decreasing the amount of primary energy (fuel) and carried on the governor. Simulation in governor analysis study as load frequency control at PLTG using fuzzy logic controller is done by giving four types of cultivation that is 0,1 pu, 0,2pu, 0,3 pu and 0,4 pu. The simulation is done to compare the dynamic frequency response output and the resulting stability time using fuzzy logic controller with PI controller. Based on the results of comparative analysis conducted to prove that governor as load frequency control using fuzzy logic control is better than using PI controller. This can be seen from the output response frequency and time stability.