An Application of Inrush Current Suppression Technology Based on CNN in Switching Operation of High-voltage Built-in High-impedance Transformer

Author(s):  
Qianwen Guo ◽  
Jin Wang ◽  
Fangqing Zheng ◽  
Gang Du ◽  
Lu Zhu ◽  
...  

2013 ◽  
Vol 732-733 ◽  
pp. 958-964
Author(s):  
Yao Zhao ◽  
Yu De Yang ◽  
Yan Hong Pan ◽  
Le Qi

The feasibility of transformer fast reenergizing with neutral point ungrounded after the external fault being removed is analyzed in this paper. By calculating overvoltage and discriminating magnetizing inrush current, it analyzes four ways to restore power of transformer and chooses the optimal strategy which is safe and time-saving. The result shows that in the case of transformer neutral point ungrounded, closing the low-voltage circuit side breaker before the high-voltage, which can effectively limit over-voltage in a safe range. The second harmonic characteristic of magnetizing waveform may disappear, while the intermittent angle characteristics are still significant. With the help of the intermittent angle principle, transformer differential protection may not misuse. The average time for each customer interruption is reduced from 40 minutes to 10 minutes and saves an hour for engineer on the way back and forth. It will greatly improve power supply reliability.



Nano Energy ◽  
2021 ◽  
pp. 106137
Author(s):  
Shan Lu ◽  
Wenqian Lei ◽  
Lingxiao Gao ◽  
Xin Chen ◽  
Daqiao Tong ◽  
...  


The operation of high-power industrial electrical installations, particularly in metallurgy and the oil and gas industry, is associated with complex technological processes that require increased attention to the equipment used, as such equipment is used in complex and dangerous production conditions and in continuous operation facilities. High-voltage air and gas compressors are objects with increased electrical energy consumption and have significant starting currents. These circumstances affect both the shape of the supply voltage and the state of the energy system in general. Currently, the development of methods for limiting inrush currents is an urgent task for objects used in industrial enterprises. Introducing a compressor into the technological process is sometimes requires prior coordination of its start with the equipment in operation, especially that with a high power consumption. The paper studies the existing control system as well as ways to upgrade the system to improve its energy performance.



Author(s):  
Wenbin Cao ◽  
Xianggen Yin ◽  
Zhe Zhang ◽  
Yuanlin Pan ◽  
Yuxue Wang ◽  
...  


1998 ◽  
Vol 26 (5) ◽  
pp. 1437-1443 ◽  
Author(s):  
J.H. Degnan ◽  
G.F. Kiuttu ◽  
P.J. Turchi ◽  
J.D. Graham ◽  
J.H. Goforth ◽  
...  


2012 ◽  
Vol 717-720 ◽  
pp. 1081-1084 ◽  
Author(s):  
Tsuyoshi Funaki ◽  
Yuki Nakano ◽  
Takashi Nakamura

SiC power device is expected to have high breakdown voltage with low on resistance, which cannot be attainable for conventional Si device. This study evaluates the switching performance of high voltage SiC MOSFETs with comparing to that of conventional Si power MOSFET having equivalent breakdown voltage. To this end, turn-on and turn-off switching operation of MOSFETs are assessed with resistive load for same conduction current density. Though the on resistance of SiC MOSFETs are quite lower than Si MOSFET, especially for trench gate type. But, SiC MOSFETs have larger terminal capacitance. Therefore, SiC MOSFETs show slower switching speed than Si MOSFETs for same current density condition.