Controller Development for Reactive Power Flow Management Between DSO and TSO Networks

Author(s):  
Katja Sirvio ◽  
Mike Mekkanen ◽  
Kimmo Kauhaniemi ◽  
Hannu Laaksonen ◽  
Ari Salo ◽  
...  
Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4519
Author(s):  
Stefano Bifaretti ◽  
Vincenzo Bonaiuto ◽  
Sabino Pipolo ◽  
Cristina Terlizzi ◽  
Pericle Zanchetta ◽  
...  

The role of distributor system operators is experiencing a gradual but relevant change to include enhanced ancillary and energy dispatch services needed to manage the increased power provided by intermittent distributed generations in medium voltage networks. In this context, the paper proposes the insertion, in strategic points of the network, of specific power electronic systems, denoted as active nodes, which permit the remote controllability of the active and reactive power flow. Such capabilities, as a further benefit, enable the distributor system operators to provide ancillary network services without requiring any procurement with distributed generation systems owners. In particular, the paper highlights the benefits of active nodes, demonstrating their capabilities in reducing the inverse power flow issues from medium to high voltage lines focusing on a network cluster including renewable energy resources. As a further novelty, this study has accounted for a real cluster operated by the Italian distributor system operator Areti. A specific simulation model of the electrical lines has been implemented in DigSilent PowerFactory (DIgSILENT GmbH–Germany) software using real operating data obtained during a 1-year measurement campaign. A detailed cost-benefit analysis has been provided, accounting for different load flow scenarios. The results have demonstrated that the inclusion of active nodes can significantly reduce the drawbacks related to the reverse power flow.


2000 ◽  
Author(s):  
Sriram Chandrasekaran ◽  
Douglas K. Lindner ◽  
Don Leo

Abstract In this paper we study the closed loop power flow characteristics between a controlled piezoelectric actuator and a current controlled drive amplifier for two different structural control laws. We determine the real and reactive power flow through the structure and actuator into the amplifier when the structure is excited with a sinusoidal disturbance force under both control laws. The dependence of the real and reactive components of the power on the material properties of the actuator, structure and the configuration of the controller is presented. These real and reactive power estimates are useful for sizing the drive amplifier for the actuator.


Author(s):  
A. Naveena ◽  
M.Venkateswara Rao

The equipments based on the power electronics have been improved under the name of Flexible Alternating Current Transmission Systems (FACTS) in the last years. Unified Power Flow Controller (UPFC) is the most widely used FACTS device to control the power flow and to optimize the system stability in the transmission line. UPFC is a FACTS devices that can control active and reactive power flow in transmission line by means of injection controllable series voltage to the transmission line. This paper proposes a new connection for a Unified Power Flow Controller (UPFC) to control the active and reactive power flow control in two sides of a transmission line independently and it regulates bus voltage in the same transmission line, furthermore it is possible to balance line current too. This connection of the UPFC will be called an center node UPFC (C_UPFC). It is one of the newest devices within the FACTS technology. The structure and capability of the C_UPFC is discussed and its control scheme is based on the d-q orthogonal coordinates. According to this, the performance of UPFC for several modes of operations using different control mechanisms based on Proportional-Integral (PI) and PID based controllers has been studied. The obtained simulation results from Matlab/simulink confirm the effective features.


Sign in / Sign up

Export Citation Format

Share Document