Long-term load balancing program in LV distribution networks

Author(s):  
A. Raminfard ◽  
S. M. Shahrtash ◽  
T. Herizchi ◽  
H. Khoshkhoo
Electrician ◽  
2019 ◽  
Vol 12 (2) ◽  
pp. 33
Author(s):  
Osea Zebua ◽  
Noer Soedjarwanto ◽  
Jemi Anggara

Intisari — Stabilitas tegangan telah menjadi perhatian yang penting dalam operasi jaringan distribusi tenaga listrik. Ketidakstabilan tegangan dapat menyebabkan kerusakan pada peralatan-peralatan listrik bila terjadi dalam waktu yang lama. Makalah ini bertujuan untuk merancang dan membuat peralatan deteksi stabilitas tegangan jangka panjang pada jaringan tegangan rendah. Sensor tegangan dan sensor arus digunakan untuk memperoleh data tegangan dan arus. Mikrokontroler Arduino digunakan untuk memproses perhitungan deteksi stabilitas tegangan jangka panjang dari data tegangan yang diperoleh dari sensor. Hasil deteksi kondisi stabilitas tegangan ditampilkan dengan indikator lampu led. Hasil pengujian pada jaringan distribusi tegangan rendah tiga fasa menunjukkan bahwa peralatan dapat mendeteksi gangguan stabilitas tegangan jangka panjang secara online dan dinamis.Kata kunci — Deteksi, stabilitas tegangan jangka panjang, jaringan distribusi tegangan rendah. Abstract — Voltage stability has become important concern in the operation of electric power distribution networks. Voltage instability can cause damage to electrical equipments if it occurs for a long time. This paper aims to design and build long-term voltage stability detection equipment on low-voltage network. Voltage sensors and current sensors are used to obtain voltage and current data. The Arduino microcontroller is used to process calculation of long-term voltage stability detection from data obtained from the sensors. The results of detection of voltage stability conditions are displayed with the LED indicators. Test result on three-phase low-voltage distribution network shows that equipment can detect long–term voltage stability disturbance online and dynamically.Keywords— Detection, long-term voltage stability, low-voltage distribution network.


2017 ◽  
Vol 144 ◽  
pp. 163-174 ◽  
Author(s):  
Raul V.A. Monteiro ◽  
Geraldo C. Guimarães ◽  
Fabricio A.M. Moura ◽  
Madeleine R.M.C. Albertini ◽  
Fernando B. Silva

2016 ◽  
Vol 2016 (5) ◽  
pp. 69-91
Author(s):  
Yuliya Orlova ◽  
Olga Kadreva

The paper investigates the mid-term results of the tariff regulation influence on the amount of capital expenditures in Russian electricity distribution sector. We estimate panel data with the dynamic investment model using system GMM method. We showed that horizon of tariff regulation period is statistically significant and transition from the short-term regulation to the long-term tariff system had positive effect on the amount of regulated companies’ investments. At the same time we found that the design of long-term regulation applied in Russia in 2009–2013 (type of RAB-regulation and long-term indexation) was not statistically significant to the amount of investments. All over all, the amount of investments in electricity distribution networks has similar to European peers explanatory factors. The obtained results are important to the further improvement of regulation in power energy and can be applied in district heating as well.


2010 ◽  
Vol 28 (No. 6) ◽  
pp. 557-563 ◽  
Author(s):  
J. Říhová Ambrožová ◽  
J. Říha ◽  
J. Hubáčková ◽  
I. Čiháková

Drinking water is safe water, from the perspective of long-term use is does not cause any disease, pathogenic and hygienically unsafe microorganisms do not spread in it and customers enjoy its consumption. Drinking water is regarded as a foodstuff, therefore the known HACCP system can be used in the control system which can be applied not only directly to the final product, but also to the whole system of drinking water production, distribution, and accumulation. Even if there is no problem concerning the water processing and the technological line is well adjusted, the quality of drinking water is subsequently deteriorated by its transportation and accumulation. The condition and character of the operated distribution network and reservoirs are significantly and substantially related to the maintenance of the biological stability and quality of drinking water. This is well confirmed by biological audits of the distribution networks and water reservoirs. A significant fact is the negative influence of the secondary contamination by air in the reservoir facilities and the occurrence of microorganisms (fungi, bacteria) in free water and in biofilms. The findings obtained in the framework of biological audits were so alarming that the outputs of biological audits contributed to the reconsideration of the efficiency of the standard for the construction and design of water reservoirs and pointed out the necessity of its review.


Sign in / Sign up

Export Citation Format

Share Document