Pecision voltage regulation on the 5 KHz, 3.125 MW ETA-II pulsed power system

Author(s):  
J.A. Watson ◽  
A.N. Payne ◽  
S.E. Sampayan ◽  
C.W. Ollis
2021 ◽  
Vol 92 (5) ◽  
pp. 054707
Author(s):  
Rong Chen ◽  
Baoliang Qian ◽  
Jianhua Yang ◽  
Xinbing Cheng ◽  
Jiuyuan Geng

Author(s):  
G. Fusco ◽  
M. Russo

This paper proposes a simple design procedure to solve the problem of controlling generator transient stability following large disturbances in power systems. A state-feedback excitation controller and power system stabilizer are designed to guarantee robustness against uncertainty in the system parameters. These controllers ensure satisfactory swing damping and quick decay of the voltage regulation error over a wide range of operating conditions. The controller performance is evaluated in a case study in which a three-phase short-circuit fault near the generator terminals in a four-bus power system is simulated.


2013 ◽  
Vol 2013 ◽  
pp. 1-8
Author(s):  
Mohammad Rasool Mojallizadeh ◽  
Bahram Karimi

The power electronic interface between a satellite electrical power system (EPS) with a photovoltaic main source and battery storage as the secondary power source is modelled based on the state space averaging method. Subsequently, sliding mode controller is designed for maximum power point tracking of the PV array and load voltage regulation. Asymptotic stability is ensured as well. Simulation of the EPS is accomplished using MATLAB. The results show that the outputs of the EPS have good tracking response, low overshoot, short settling time, and zero steady-state error. The proposed controller is robust to environment changes and load variations. Afterwards, passivity based controller is provided to compare the results with those of sliding mode controller responses. This comparison demonstrates that the proposed system has better transient response, and unlike passivity based controller, the proposed controller does not require reference PV current for control law synthesis.


Author(s):  
Richard T. Meyer ◽  
Raymond A. DeCarlo ◽  
Steve D. Pekarek ◽  
Jing Sun ◽  
Hyeongjun Park

Power management of a ship’s electrical system has become important due to increasing loads from manpower-reducing automation, greater power requirements of advanced weapons and sensors, introduction of all electric propulsion, and the increasing cost of oil-based fossil fuels. A coordinated power management strategy of the ship’s electric power grid is desired to optimally allocate power flows and minimize fuel consumption. This paper develops such an optimal power management system for an interconnected, supervisory-level ship power system model based upon a ship power system test bed developed for the Office of Naval Research. The ship power system consists of two electrical generators, one rated at 59 kW to represent a gas turbine engine-generator pair and the other rated at 11 kW to represent a diesel generator, an 8 kW pulsed power load that represents the discharge and charge of a capacitor bank for an electromagnetic railgun system, and 37 kW ship propulsion system comprised of an induction motor coupled to the propeller shaft. The ship propulsion system’s induction motor has switched operation with two modes of operation, propelling and generating; the latter mode means that excess kinetic energy during ship slowing can be used to charge the capacitor bank for loads such as pulsed power loads. Given the switched system model, the paper sets forth a hybrid model predictive control strategy based on a minimization of a performance index that trades off fuel consumption, velocity tracking error, and electrical bus voltage error. The optimization is performed using a relaxed representation of the control problem (termed the embedding method) and collocation for discretization with traditional numerical programming to compute the mode and continuous control inputs. The methodology avoids the computational complexity associated with alternative approaches, e.g., mixed-integer programming. Numerical optimization is performed with MATLAB’s sqpLineSearch. To demonstrate the power management approach, a scenario is simulated where the ship is to follow a changing desired velocity while simultaneously maintaining the bus voltage at a desired value, keeping the 11 kW generator at a fuel efficient operating point, and minimizing the fuel use of the 59 kW generator.