Power quality indicators

Author(s):  
X. Mamo ◽  
J. Javerzac
Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1951
Author(s):  
Mihaela Popescu ◽  
Alexandru Bitoleanu ◽  
Mihaita Linca ◽  
Constantin Vlad Suru

This paper presents the use of a three-phase four-wire shunt active power filter to improve the power quality in the Department of Industrial Electronics of a large enterprise from Romania. The specificity is given by the predominant existence of single-phase consumers (such as personal computers, printers, lighting and AC equipment). In order to identify the power quality indicators and ways to improve them, an A-class analyzer was used to record the electrical quantities and energy parameters in the point of common coupling (PCC) with the nonlinear loads for 27 h. The analysis shows that, in order to improve the power quality in PCC, three goals must be achieved: the compensation of the distortion power, the compensation of the reactive power and the compensation of the load unbalance. By using the conceived three-leg shunt active power filter, controlled through the indirect current control method in an original variant, the power quality at the supply side is very much improved. In the proposed control algorithm, the prescribed active current is obtained as a sum of the loss current provided by the DC voltage and the equivalent active current of the unbalanced load. The performance associated with each objective of the compensation is presented and analyzed. The results show that all the power quality indicators meet the specific standards and regulations and prove the validity of the proposed solution.


2020 ◽  
Vol 11 (7-2020) ◽  
pp. 58-66
Author(s):  
Vera V. Yaroshevich ◽  
◽  
Aleksei S. Karpov ◽  
Galina P. Fastiy ◽  
Sergei V. Smotrov ◽  
...  

The systematization and analysis of the results of monitoring registrations of electric power quality indicators (PQS) on substation buses feeding large industrial enterprises of the Murmansk region was carried out. The example of existing substations shows the problems of high-energy facilities that have consumers with non-linear parameters. The problems of electromagnetic compatibility of industrial consumers with the mains have been identified. The need for research to identify the causes of non-compliance is proved. A number of the most common and effective measures to limit the distortion of the SCE are proposed.


Power quality issues concern absolutely all spheres of human activity, from household to economy and transportation. Standardization, monitoring, management, and coordination to ensure electromagnetic compatibility in the power supply system are the subject of constantly ongoing research in most countries. In order to attract attention to issues of the harmonic current, this study focused on the harmonic current distortions observed on the level of urban electricity users. The paper considers the aspects of consolidating terminology and structure of power quality indicators. We carefully reviewed the current and voltage waveform distortions and related harmonic components. We also summed up the power quality indicators currently used around the world as a flowchart. Based on the results of measurements of quality indicators at the existing urban infrastructure facilities, a comparative analysis with the IEEE 519-2014 standard requirements was performed. As a result of the field measurements analysis, an unsatisfactory situation in terms of harmonic current distortions was revealed; the most probable causes and consequences of poor current quality are described.


2021 ◽  
Author(s):  
E.N. Sosnina ◽  
S.A. Petritsky ◽  
S.N. Yurtaev ◽  
A.M. Mamonov ◽  
A.N. Fitasov

Sign in / Sign up

Export Citation Format

Share Document