Determination of resonance frequency and sensitivity of resonant microsensors with electrostatic excitation and capacitive detection

Author(s):  
C. Moldovan ◽  
F. Babarada ◽  
B. Stefanescu ◽  
R. Moldovan
Author(s):  
Ingrid Kästel ◽  
Giles de Quincey ◽  
Jörg Neugebauer ◽  
Robert Sader ◽  
Peter Gehrke

Abstract Background There is disagreement about the optimal torque for tightening smartpegs for resonance frequency analysis (RFA). Subjective finger pressure during hand tightening could affect the reliability of the resulting values. The aim of the current study was therefore to assess whether or not the insertion torque of a smartpeg magnetic device influences the implant stability quotient (ISQ) value during RFA. Methods Thirty self-tapping screw implants (XiVE S, Dentsply Sirona Implants, Bensheim, Germany) with a diameter of 3.8 mm and a length of 11 mm were inserted in three cow ribs with a bone quality of D1. The RFA value of each implant was measured (Ostell, FA W&H Dentalwerk, Bürmoos, Austria) in two orthogonal directions (mesial and buccal) after tightening the corresponding smartpeg type 45 with a mechanically defined value of 5 Ncm (Meg Torq device, Megagen, Daegu, South Korea) (test). Additionally, 4 different examiners measured the RFA after hand tightening the smartpegs, and the results were compared (control). Insertion torque values were determined by measuring the unscrew torque of hand seated smartpegs (Tohnichi Manufacturing Co. Ltd, Tokyo, Japan). Results The ISQ values varied from 2 to 11 Ncm by hand tightening and from 2 to 6 Ncm by machine tightening. The comparison of hand and machine tightening of smartpegs displayed only minor differences in the mean ISQ values with low standard deviations (mesial 79.76 ± 2,11, buccal 77.98 ± 2,) and no statistical difference (mesial p = 0,343 and buccal p = 0,890). Conclusions Manual tightening of smartpeg transducers allows for an objective and reliable determination of ISQ values during RFA.


Author(s):  
Rammah Alahnomi ◽  
Natasha Binti Abd Hamid ◽  
Zahriladha Zakaria ◽  
Tole Sutikno ◽  
Amyrul Azuan Mohd Bahar

<p>This paper presents a single port rectangular ring resonator sensor for material characterizations. The proposed sensor is designed at operating resonance frequency of 4 GHz. The sensor consists of micro-strip transmission line and ring resonator with applying the enhancement method to the coupling gaps. The using of enhancement method is to improve the return loss of the sensor and sensitivity in terms of Q-factor, respectively. Furthermore, the proposed sensor is designed and fabricated on Roger 5880 substrate. Standard materials with known permittivity have been used in order to validate the sensor’s sensitivity. Based on the results, the percentage of error for the proposed rectangular sensor is 0.2% to 8%. It can be demonstrated that the proposed sensor will be useful for various applications such as medicine, bio-sensing and food industry.</p>


Sign in / Sign up

Export Citation Format

Share Document