Development of a Start-up Model of a Submersible Electric Motor When the Electric Centrifugal Pump is Installed and Set to Operating Mode

Author(s):  
Artur M Sagdatullin
2021 ◽  
Vol 2061 (1) ◽  
pp. 012027
Author(s):  
Rustem I Suleimanov ◽  
Marat Ya Khabibullin ◽  
Renard I Suleimanov

Abstract The article discusses the issues of assessing the technical condition of electric centrifugal pumps (ECP) by the methods of automated diagnostics. The factors influencing the ECP and causes of failures of the electric centrifugal pump (ECP) and the submersible electric motor (SEM) are analyzed. The results of ECP failure identifiaton using the measuring systems are presented. Recommendations on the operation of electric centrifugal pumps are provided.


2015 ◽  
Vol 6 (3) ◽  
pp. 35-46
Author(s):  
Tamas Koplyay ◽  
Brian Mitchell ◽  
Sorin Cohn ◽  
Maria Fekete ◽  
Abdelkader Jazouli

Abstract That supply chain management and logistics are a determining factor for the long term success of a company was well documented by Forrester over a half century ago [1], with the importance of the statement only growing through the intervening years.Whether consciously factored into the operating mode or not, logistics and distribution channel management plays a critical role in the life, and death, of a firm. From the rudimentary beginnings of the start-up company to the hectic world of the growth company and onto the relatively secure existence in mature markets, the value chain consisting of logistics and distribution channel linkages follows the firm, until it solidifies into immutable form of the mature value chain and begins to exert an inexorable pressure on the survival of the entire chain, and conversely the chain imposes its will on the members. The emergence of mature industry value chains is often driven by the need to monopolistically control logistics and distribution channels which provides a competitive advantage but also introduces a serious exposure to pending shock loadings of the chain.


2020 ◽  
Vol 23 (2) ◽  
pp. 48-51
Author(s):  
V. KONDRATENKO ◽  
◽  
V. KALYNYCHENKO ◽  

Mine drainage systems, which are used at the main drainage of mining enterprises, have a drive capacity of up to 1600kW. To reduce non-productive energy losses, as well as for the continuous operation of the mining company, mine pumps must be energy efficient and reliable. Analysis of downtime of drainage systems shows that the weak point is the unloading device. This fact can lead not only to the failure of the pumping unit, but also to possible prolonged downtime of the mine. The main disadvantage of the existing disk unloading devices of mine pumps is their low reliability and low service life, due to the rapid wear of the components of the unloading unit. The most vulnerable elements of the unloading device are the unloading rings. The need for frequent replacement and adjustment of the elements of the discharge unit is associated with disassembly and assembly of the pump directly in the pump chamber. Such actions require significant costs of unproductive manual labor of service personnel, and rapid wear of parts of the unloading device necessitates their constant replenishment. Malfunctions in the unloading device can cause significant pump failures. To increase the reliability and energy efficiency of mine drainage systems, the method of control of the unloading device was used. During the experimental studies it was found that cavitation phenomena during the operation of pumping units are absent and, accordingly, can not be the cause of wear of the elements of the unloading unit. When the pumps are operating in steady state, the displacement of the rotors was monitored for 3-4 hours on each pump unit. After data processing, it was obtained that the wear of the surface of the unloading rings occurs at a rate of 0.05-0.15mm in one hour. To determine the wear of the rings of unloading during start-up - stop of the pump, at first the indicators of measuring devices at the established mode of operation of the pump unit were fixed. Then the pump was turned off and on again. After starting the pump unit, we made sure that the operating mode of the unloading device did not change and compared the readings of the shaft position indicator before stopping and after starting the pump. From the measurements made it followed that stopping and starting the pump does not lead to noticeable wear of the unloading device. Therefore, it can be assumed that mainly the wear of the discharge rings occurs during the steady operation of the pump unit.


1999 ◽  
Vol 121 (3) ◽  
pp. 291-295 ◽  
Author(s):  
S. Bolpaire ◽  
J. P. Barrand

The operational range and the performances of pumps are limited by the occurrence of backflow and prerotation in the suction pipe as the flow rate is reduced. This paper presents the study of static pressure measurements and visualizations in the suction pipe, near the inlet of a centrifugal pump, at partial flow rates, in steady conditions, and during a fast start-up of the pump. The tests were carried out in water on the DERAP© test loop of the ENSAM Lille laboratory. Standard methods allowed to determine the recirculation critical flow rate. A visualization method showed that the axial extent of the recirculation and the prerotation with the flow rate is considerably reduced during a fast start-up compared to steady conditions.


Author(s):  
Anton Gorodnov ◽  
Vladimir Kornilov ◽  
Majid Abdulhameed Al-Ali ◽  
Evgenii Fedorov

Sign in / Sign up

Export Citation Format

Share Document