The article describes a way to combat fatigue effects in the details of connecting modules of an electric driven centrifugal pump unit for oil production. A constructive solution for implementing the method in relation to complex downhole conditions in the form of a multifunctional damper using a differential piston to transfer it from the transport position when lowering into the well into the working one is shown. For a full-size damper, experimental studies of its vibration- isolating characteristics have been carried out when used in the form of substrates for supporting arms of elastomers of various densities and compositions. The preferred characteristics of elastomers and their ranking for various frequencies of forced vibrations are determined. Keywords: module, connection parts; electrically driven centrifugal pump unit; electrocentrifugal pumping unit; differential piston; damper; sbstrate; vibration velocity.


Author(s):  
Anton Gorodnov ◽  
Vladimir Kornilov ◽  
Majid Abdulhameed Al-Ali ◽  
Evgenii Fedorov

Author(s):  
Fariz Qafarov Fariz Qafarov ◽  
Elnarə Səlimova Elnarə Səlimova ◽  
Aybəniz Əmirova Aybəniz Əmirova

ABSTRACT The article is devoted to vibration diagnostics, an effective method for assessing the parameters of the mechanical state of centrifugal pumping units. The use of vibration diagnostics allows, due to early detection of malfunctions, to improve target operation, increase the turnaround time and reduce the likelihood of emergency destruction of pumping unit elements. Diagnostic signs of the presence of defects in various elements of the pumping unit are presented. During the development of diagnostic methods, the character stages of the development of injuries are selected. These stages are the formation of the injury, the accumulation of injuries, collapse, and so on. consists of stages. Dynamic forces are considered to be the main cause of vibration in machine parts. It is under the influence of dynamic forces that fatigue breaks down in machine parts. The use of vibrodiagnostics in machine parts allows to accurately assess the degree of damage to its individual nodes. This, in turn, leads to improved operating conditions. In conclusion, it should be noted that vibrodiagnostics not only detects malfunctions in machines, but also reveals the causes of its formation. Keywords: vibrodiagnostics, improvement of operational conditions, determination of defects, probability of emergency destruction, repair, assessment.


2021 ◽  
Vol 2095 (1) ◽  
pp. 012090
Author(s):  
Jun Shao ◽  
Kang Ding ◽  
Dewei Wang

Abstract A pumping unit with incomplete gear and rack reversal was designed for smooth motion and low energy consumption. This paper first describes the working principle of the pumping unit. The kinematical equation of the pumping unit is established on the basis of analyzing the kinematic relationship between the first tooth meshing area, the normal meshing area and the final tooth meshing area of incomplete gear and rack. The kinematic relationship curve of the pumping unit is obtained by ADAMS simulation. The simulation results show that the theoretical model is correct. By comparing the results with the conventional pumping unit, it can be seen that: the pumping unit has a smooth movement of the up-down strokes, with fluctuations of movement only in the process of changing directions. The incomplete gear and rack drive is smooth, which can improve the kinestate of the pumping unit.


2021 ◽  
Author(s):  
Yuzar Aryadi ◽  
Azis Hidayat ◽  
Hilman Lazuardi ◽  
Syahroni Isnanto ◽  
Bonni Ariwibowo ◽  
...  

Abstract SCADA optimization platform is implemented to monitor and evaluate well performance. For Sucker Rod Pump, SCADA Optimization Software can be used to monitor the unit balance and gearbox torque. In some ways, not all required well configuration data for SCADA Optimization Software to do a calculation of counterbalance torque (CBT) for pumping unit balance and gearbox torque evaluation are available. Standard field Counterbalance Effect (CBE) measurement might be performed to calculate the CBT value. However, this standard procedure is limited to well that run on balance condition. For well with unbalance condition, the measured CBE needs to be adjusted by a correction factor which the equation will be presented in this paper. The corrected CBE value from the new equation is then inputted to the SCADA Optimization software to perform day-to-day real-time monitoring of pumping unit balance and gearbox torque. Derivation of the CBE correction factor equation is presented. Validation upon this new equation is performed by comparing the result with electrical measurement on the pumping unit motor. Using the calculated CBT from the new equation, SCADA Optimization Software performs gearbox torque and pumping unit balance analysis based on every collected dynamometer card. Calculated CBT from the new equation provided results in gearbox torque distribution pattern that match with measured electrical parameter distribution along the stroke. This CBT value assists SCADA optimization software to calculate pumping unit balance and gearbox torque. Alarm in the SCADA optimization software that coming from an anomaly on pumping unit balance and gearbox torque help operator to do preventive maintenance so that pumping unit component especially the gearbox could have longer run life.