Behavior of HV cable of power supply at short circuit and related phenomena

2013 ◽  
Vol 20 (1) ◽  
pp. 28-33 ◽  
Author(s):  
Alex Pokryvailo ◽  
Cliff Scapellati
Keyword(s):  
2019 ◽  
Vol 5 (5) ◽  
pp. 19-23
Author(s):  
Leonid A. GERMAN ◽  
◽  
Alexandr S. SEREBRYAKOV ◽  
Aleksey B. LOSKUTOV ◽  
Vladimir L. OSOKIN ◽  
...  

Author(s):  
Xin Shen ◽  
Hongchun Shu ◽  
Min Cao ◽  
Nan Pan ◽  
Junbin Qian

In distribution networks with distributed power supplies, distributed power supplies can also be used as backup power sources to support the grid. If a distribution network contains multiple distributed power sources, the distribution network becomes a complex power grid with multiple power supplies. When a short-circuit fault occurs at a certain point on the power distribution network, the size, direction and duration of the short-circuit current are no longer single due to the existence of distributed power, and will vary with the location and capacity of the distributed power supply system. The change, in turn, affects the current in the grid, resulting in the generation and propagation of additional current. This power grid of power electronics will cause problems such as excessive standard mis-operation, abnormal heating of the converter and component burnout, and communication system failure. It is of great and practical significance to study the influence of distributed power in distributed power distribution networks.


2014 ◽  
Vol 536-537 ◽  
pp. 1537-1541
Author(s):  
Juan Xiao

A marine DC uninterruptible power supply is designed. The UPS adopts PIC16C73 single-chip microcomputer to realize the battery management. Both AC power and battery power, the output voltage stability in 23 to 24 v.Via advanced battery management, two sections of charging, equalized charging and floating charging can automatic convert and the DCUPS has many functions of protection, such as over-voltage protection ,under voltage protection and short circuit protection.The actual use on the ship and other occasions showed that the DCUPS is convenient and practical,and is more simple, reliable and longer emergency power supply than the traditional AC-DC uninterruptible power supply management scheme.


2020 ◽  
Vol 12 (23) ◽  
pp. 10126
Author(s):  
Jacek Katarzyński ◽  
Marek Olesz

This paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers for operation. To define the principles of FLI measurement, several hundred measurements of the short-circuit loop impedance in the circuits fed by the UPS, in various UPS operation modes and with various FLI instruments, were made, which allowed for the definition of measurement rules that reduce the error in assessing the effectiveness of protection against electric shock by automatic disconnection of supply. Based on the analysis of voltage and current waveforms recorded during the real short-circuit tests in the circuit fed by the UPS, a proprietary algorithm for determining the short-circuit loop impedance has been proposed.


Sign in / Sign up

Export Citation Format

Share Document