Optimal Dead-Time Control Scheme for Extended ZVS Range and Burst-Mode Operation of Phase-Shift Full-Bridge (PSFB) Converter at Very Light Load

2019 ◽  
Vol 34 (11) ◽  
pp. 10823-10832 ◽  
Author(s):  
Chong-Eun Kim
Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 853
Author(s):  
Jia-You Lee ◽  
Jheng-Hung Chen ◽  
Kuo-Yuan Lo

A compact and high-efficiency power converter is the main business of today’s power industry for server power applications. To achieve high efficiency with a low-output ripple, an interleaved phase-shift full-bridge (PSFB) converter is designed, built, and tested for server power applications in this study. In this paper, dynamic dead time control is proposed to reduce the switching loss in the light load condition. The proposed technique reduces the turn-off switching loss and allows a wide range of zero-voltage switching. Moreover, the current ripple of the output inductor can be reduced with the interleaved operation. To verify the theoretical analysis, the proposed PSFB converter is simulated, and a 3 kW prototype is constructed. The experimental results confirm that the conversion efficiency is as high as 97.2% at the rated power of 3 kW and 92.95% at the light load of 300 W. The experimental transient waveforms demonstrated that the voltage spike or drop is less than 2 V in the fast-fluctuating load conditions from 0% load to 60% load and 40% load to 100% load.


Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2836
Author(s):  
Nuraina Syahira Mohd Sharifuddin ◽  
Nadia M. L. Tan ◽  
Hirofumi Akagi

This paper presents the performance of a three-phase bidirectional isolated DC-DC converter (3P-BIDC) in wye-wye (Yy), wye-delta (Yd), delta-wye (Dy), and delta-delta (Dd) transformer configurations, using enhanced switching strategy that combines phase-shift modulation and burst-mode switching. A simulation verification using PSCAD is carried out to study the feasibility and compare the efficiency performance of the 3P-BIDC with each transformer configuration, using intermittent switching, which combines the conventional phase-shift modulation (PSM) and burst-mode switching, in the light load condition. The model is tested with continuous switching that employs the conventional PSM from medium to high loads (greater than 0.3 p.u.) and with intermittent switching at light load (less than 0.3 p.u), in different transformer configurations. In all tests, the DC-link voltages are equal to the transformer turns ratio of 1:1. This paper also presents the power loss estimation in continuous and intermittent switching to verify the modelled losses in the 3P-BIDC in the Yy transformer configuration. The 3P-BIDC is modelled by taking into account the effects that on-state voltage drop in the insulated-gate bipolar transistor (IGBTs) and diodes, snubber capacitors, and three-phase transformer copper winding resistances will have on the conduction and switching losses, and copper losses in the 3P-BIDC. The intermitting switching improves the efficiency of the DC-DC converter with Yy, Yd, Dy, and Dd connections in light-load operation. The 3P-BIDC has the best efficiency performance using Yy and Dd transformer configurations for all power transfer conditions in continuous and intermittent switching. Moreover, the highest efficiency of 99.6% is achieved at the light power transfer of 0.29 p.u. in Yy and Dd transformer configurations. However, the theoretical current stress in the 3P-BIDC with a Dd transformer configuration is high. Operation of the converter with Dy transformer configuration is less favorable due to the efficiency achievements of lower than 95%, despite burst-mode switching being applied.


Sign in / Sign up

Export Citation Format

Share Document