Recovery of Withstanding Voltage After Direct Current Interruption Using Vacuum Circuit Breakers

Author(s):  
Haruki Ejiri ◽  
Ryo Kikuchi ◽  
Akiko Kumada ◽  
Kunihiko Hidaka ◽  
Akihiro Suwa ◽  
...  
Electronics ◽  
2021 ◽  
Vol 10 (10) ◽  
pp. 1204
Author(s):  
Gul Ahmad Ludin ◽  
Mohammad Amin Amin ◽  
Hidehito Matayoshi ◽  
Shriram S. Rangarajan ◽  
Ashraf M. Hemeida ◽  
...  

This paper proposes a new and surge-less solid-state direct current (DC) circuit breaker in a high-voltage direct current (HVDC) transmission system to clear the short-circuit fault. The main purpose is the fast interruption and surge-voltage and over-current suppression capability analysis of the breaker during the fault. The breaker is equipped with series insulated-gate bipolar transistor (IGBT) switches to mitigate the stress of high voltage on the switches. Instead of conventional metal oxide varistor (MOV), the resistance–capacitance freewheeling diodes branch is used to bypass the high fault current and repress the over-voltage across the circuit breaker. The topology and different operation modes of the proposed breaker are discussed. In addition, to verify the effectiveness of the proposed circuit breaker, it is compared with two other types of surge-less solid-state DC circuit breakers in terms of surge-voltage and over-current suppression. For this purpose, MATLAB Simulink simulation software is used. The system is designed for the transmission of 20 MW power over a 120 km distance where the voltage of the transmission line is 220 kV. The results show that the fault current is interrupted in a very short time and the surge-voltage and over-current across the proposed breaker are considerably reduced compared to other topologies.


2010 ◽  
Vol 25 (1) ◽  
pp. 206-211 ◽  
Author(s):  
A. Balestrero ◽  
L. Ghezzi ◽  
M. Popov ◽  
L. van der Sluis

Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3217
Author(s):  
Yun Geng ◽  
Xiaofei Yao ◽  
Jinlong Dong ◽  
Xue Liu ◽  
Yingsan Geng ◽  
...  

The prestrike phenomenon in vacuum circuit breakers (VCBs) is interesting but complicated. Previous studies mainly focus on the prestrike phenomenon in single-break VCBs. However, experimental work on prestrike characteristics of double-break VCBs cannot be found in literature. This paper aims to experimentally determine the probabilistic characteristics of prestrike gaps in a double-break VCB consisting of two commercial vacuum interrupters (VIs) in series under direct current (DC) voltages. As a benchmark, single-break prestrike gaps were measured by short-circuiting one of the VIs in a double break. The experimental results show that the 50% prestrike gap d50 of each VI in a double break, which is calculated with the complementary Weibull distribution, was significantly reduced by 25% to 72.7% compared with that in a single break. Due to the voltage-sharing effect in the double-break VCB, scatters in prestrike gaps of each VI in a double break was smaller than that in a single break. However, without the sharing-voltage effect, d50 of the low-voltage side in the double break was 65% higher than that of the same VI in the single break, which could be caused by the asynchronous property of mechanical actuators, the difference of the inherent prestrike characteristics of each VI and the unequal voltage-sharing ratio of VIs.


2017 ◽  
Vol 4 (2) ◽  
pp. 173-176
Author(s):  
D. Baron ◽  
S. Ettingshausen ◽  
M. Koletzko ◽  
A. Lawall ◽  
T. Rettenmaier ◽  
...  

The method of controlling high-current switching arcs by transverse magnetic fields (TMF) forcing the constricted arc to rotate in a contact system is being applied successfully to improve the breaking capability of vacuum interrupters and gas circuit breakers. We describe the behavior of magnetically driven switching arcs in vacuum and in gas environment. We report on experiments using high-velocity videography, magnetic probes, and spectroscopy; they deliver the velocity, the temperature and the voltage of an arc. We present models and simulations of the moving constricted arc burning in metal vapor and in air. And we describe a particular switching application of TMF arc control and explain a scaling law of the contact size with the current interruption capability.


2002 ◽  
Vol 73 (4) ◽  
pp. 1945-1948 ◽  
Author(s):  
A. M. Zolfaghari ◽  
E. Kellogg ◽  
S. Wendt ◽  
J. Gray

Sign in / Sign up

Export Citation Format

Share Document