Resonance Behavior and Sensitivity to Detect Mechanical Change in Transformer Winding: Shunt Current Versus Neutral Current

2015 ◽  
Vol 30 (5) ◽  
pp. 2276-2283 ◽  
Author(s):  
Saurav Pramanik
2021 ◽  
Vol 2 (2) ◽  
pp. 22-28
Author(s):  
Vasily S. LARIN ◽  
◽  
Daniil A. MATVEEV ◽  

In the first part of the article, based on the results of theoretical studies performed for a simplified transformer winding equivalent scheme, it was shown that the damping factors can be estimated from the width of the resonant peaks of the frequency responses of the module and the reactive component of the voltage at the midpoint of the equivalent scheme, as well as the active component of the input admittance and neutral current of the considered resonant scheme. In this part of the article, the practical possibility of applying the obtained theoretical relations between the damping factors and the width of resonant peaks in relation to the frequency responses of power transformer windings is considered. The results of calculations of the damping factors at the two power transformers made by using the fitting of the free component of transient voltage and by determining the width of the resonance peaks of the active component of winding neutral current and the voltage transfer function, corresponding to intermediate points of the winding. It is shown that the evaluation of the values of the winding damping factors can be performed as a byproduct of transformer condition assessment by frequency response analysis (FRA).


2016 ◽  
Vol 136 (7) ◽  
pp. 654-662
Author(s):  
Satoru Miyazaki ◽  
Yoshinobu Mizutani ◽  
Akira Taguchi ◽  
Junichi Murakami ◽  
Naokazu Tsuji ◽  
...  

Author(s):  
Zhenhua Li ◽  
Weihui Jiang ◽  
Li Qiu ◽  
Zhenxing Li ◽  
Yanchun Xu

Background: Winding deformation is one of the most common faults in power transformers, which seriously threatens the safe operation of transformers. In order to discover the hidden trouble of transformer in time, it is of great significance to actively carry out the research of transformer winding deformation detection technology. Methods: In this paper, several methods of winding deformation detection with on-line detection prospects are summarized. The principles and characteristics of each method are analyzed, and the advantages and disadvantages of each method as well as the future research directions are expounded. Finally, aiming at the existing problems, the development direction of detection method for winding deformation in the future is prospected. Results: The on-line frequency response analysis method is still immature, and the vibration detection method is still in the theoretical research stage. Conclusion: The ΔV − I1 locus method provides a new direction for on-line detection of transformer winding deformation faults, which has certain application prospects and practical engineering value.


1974 ◽  
Vol 33 (7) ◽  
pp. 448-451 ◽  
Author(s):  
S. J. Barish ◽  
Y. Cho ◽  
M. Derrick ◽  
L. G. Hyman ◽  
J. Rest ◽  
...  