Correspondence - 3-D ultrasonic strain imaging based on a linear scanning system

Author(s):  
Qinghua Huang ◽  
Bo Xie ◽  
Pengfei Ye ◽  
Zhaohong Chen
2021 ◽  
Author(s):  
Anton Shchepetilnikov ◽  
Pavel Gusikhin ◽  
Viacheslav Muravev ◽  
Boris Kaysin ◽  
Gombo Tsydynzhapov ◽  
...  

Author(s):  
C.J. Stuart ◽  
B.E. Viani ◽  
J. Walker ◽  
T.H. Levesque

Many techniques of imaging used to characterize petroleum reservoir rocks are applied to dehydrated specimens. In order to directly study behavior of fines in reservoir rock at conditions similar to those found in-situ these materials need to be characterized in a fluid saturated state.Standard light microscopy can be used on wet specimens but depth of field and focus cannot be obtained; by using the Tandem Scanning Confocal Microscope (TSM) images can be produced from thin focused layers with high contrast and resolution. Optical sectioning and extended focus images are then produced with the microscope. The TSM uses reflected light, bulk specimens, and wet samples as opposed to thin section analysis used in standard light microscopy. The TSM also has additional advantages: the high scan speed, the ability to use a variety of light sources to produce real color images, and the simple, small size scanning system. The TSM has frame rates in excess of normal TV rates with many more lines of resolution. This is accomplished by incorporating a method of parallel image scanning and detection. The parallel scanning in the TSM is accomplished by means of multiple apertures in a disk which is positioned in the intermediate image plane of the objective lens. Thousands of apertures are distributed in an annulus, so that as the disk is spun, the specimen is illuminated simultaneously by a large number of scanning beams with uniform illumination. The high frame speeds greatly simplify the task of image recording since any of the normally used devices such as photographic cameras, normal or low light TV cameras, VCR or optical disks can be used without modification. Any frame store device compatible with a standard TV camera may be used to digitize TSM images.


Author(s):  
Judith M. Brock ◽  
Max T. Otten

A knowledge of the distribution of chemical elements in a specimen is often highly useful. In materials science specimens features such as grain boundaries and precipitates generally force a certain order on mental distribution, so that a single profile away from the boundary or precipitate gives a full description of all relevant data. No such simplicity can be assumed in life science specimens, where elements can occur various combinations and in different concentrations in tissue. In the latter case a two-dimensional elemental-distribution image is required to describe the material adequately. X-ray mapping provides such of the distribution of elements.The big disadvantage of x-ray mapping hitherto has been one requirement: the transmission electron microscope must have the scanning function. In cases where the STEM functionality – to record scanning images using a variety of STEM detectors – is not used, but only x-ray mapping is intended, a significant investment must still be made in the scanning system: electronics that drive the beam, detectors for generating the scanning images, and monitors for displaying and recording the images.


2006 ◽  
Vol 5 (1) ◽  
pp. 46-46
Author(s):  
N ARTIS ◽  
D OXBOROUGH ◽  
G WILLIAMS ◽  
L TAN ◽  
C PEPPER

VASA ◽  
2017 ◽  
Vol 46 (2) ◽  
pp. 108-115 ◽  
Author(s):  
Christian Alexander Schaefer ◽  
Anna Katharina Blatzheim ◽  
Sebastian Gorgonius Passon ◽  
Kristin Solveig Pausewang ◽  
Nadjib Schahab ◽  
...  

Abstract. Background: The beneficial effect of statin therapy on the progress of atherosclerotic disease has been demonstrated by numerous studies. Vascular strain imaging is an arising method to evaluate arterial stiffness. Our study examined whether an influence of statin therapy on the vessel wall could be detected by vascular strain imaging. Patients and methods: 88 patients with recently detected atherosclerosis underwent an angiological examination including ankle-brachial index (ABI), pulse wave index (PWI), central puls ewave velocity and duplex ultrasound. Captures for vascular strain analysis were taken in B-mode during ultrasound examination of the common carotid artery and evaluated using a workstation equipped with a speckle tracking based software. A statin therapy was recommended and after six months a follow-up examination took place. Meanwhile, the non-adherence of a group of patients (N = 18) lead to a possibility to observe statin effects on the vascular strain. Results: In the statin non-adherent group the ABI decreased significantly to a still non-pathological level (1.2 ± 0.2 vs. 1.0 ± 0.2; p = 0.016) whereas it stagnated in the adherent group (1.0 ± 0.2 vs. 1.0 ± 0.2; p = 0.383). The PWI did not differ in the non-adherent group (180.5 ± 71.9 vs. 164.4 ± 75.8; p = 0.436) but under statin therapy it decreased significantly (261.8 ± 238.6 vs. 196.4 ± 137.4; p = 0.016). In comparison to the adherent group (4.2 ± 2.0 vs. 4.0 ± 1.8; p = 0.548) under statin therapy the radial strain decreased significantly in the non-adherent group (4.7 ± 2.0 vs. 3.3 ± 1.1; p = 0.014). Conclusions: Our findings reveal a beneficial influence of statin therapy on the arterial wall detected by vascular strain analysis.


Sign in / Sign up

Export Citation Format

Share Document