The role of corneal endothelial morphology in graft assessment and prediction of endothelial cell loss during organ culture of human donor corneas

2016 ◽  
Vol 95 (2) ◽  
pp. 205-210 ◽  
Author(s):  
Martin Hermel ◽  
Sabine Salla ◽  
Matthias Fuest ◽  
Peter Walter
2007 ◽  
Vol 143 (2) ◽  
pp. 374
Author(s):  
N. Builles ◽  
L. Kodjikian ◽  
C. Burillon ◽  
O. Damour

Ophthalmology ◽  
1984 ◽  
Vol 91 (3) ◽  
pp. 285-289 ◽  
Author(s):  
William M. Bourne ◽  
Donald J. Doughman ◽  
Richard L. Lindstrom ◽  
Michael J. Kolb ◽  
Elizabeth Mindrup ◽  
...  

Author(s):  
Bishr Agha ◽  
Raimund Forster ◽  
Thomas Kohnen ◽  
Ingo Schmack

Abstract Purpose To evaluate the potential impact of rebubbling on the anterior segment parameters and refractive outcomes in patients with graft detachment following uneventful DMEK for Fuchs endothelial dystrophy (FED). Methods Retrospective institutional cohort study of comparing 34 eyes of 31 patients with rebubbling for graft detachment following Descemet membrane endothelial keratoplasty (DMEK) to 33 eyes of 28 patients with uneventful DMEK. Main outcome parameters were various corneal parameters obtained by Scheimpflug imaging, refractive outcome, corrected distance visual acuity (CDVA), and endothelial cell density (ECD). Results Anterior and posterior corneal astigmatism, corneal densitometry, central corneal thickness, and anterior chamber depth and volume showed no significant differences. Preoperative distribution of astigmatism axis orientations showed a high proportion of anterior corneal with-the-rule astigmatism (71%) in eyes requiring rebubbling. Mean postoperative cylinder in the rebubbling group (1.21 ± 0.85 D) was significantly higher compared to the controls (p = 0.04), while differences in spherical equivalent (SE) were insignificant (p = 0.24). Postoperative CDVA was 0.11 ± 0.11 in the control group compared to 0.21 ± 0.17 in the rebubbling group (p = 0.03). Eyes with subsequent rebubbling demonstrated a significantly higher endothelial cell loss (56% versus 37%) (p < 0.001). Conclusion Apart from higher cylinder values, refractive outcome and corneal parameters assessed by Scheimpflug imaging were comparable in eyes with rebubbling and controls. However, a reduced visual acuity and an increased endothelial cell loss should be taken into consideration prior to rebubbling especially in eyes with circumscribed graft detachment.


2021 ◽  
Vol 10 (11) ◽  
pp. 2421
Author(s):  
Dominika Janiszewska-Bil ◽  
Barbara Czarnota-Nowakowska ◽  
Katarzyna Krysik ◽  
Anita Lyssek-Boroń ◽  
Dariusz Dobrowolski ◽  
...  

We compared the visual and refractive outcomes, intraocular pressure (IOP), endothelial cell loss (ECL), and adverse events in keratoconus patients after deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) with the best corrected visual acuity (BCVA) below 0.3 (logMAR 0.52). This is a prospective, comparative cohort study of 90 eyes (90 patients) with a clinical diagnosis of keratoconus. Patients underwent a complete eye examination before the surgical approach, 6 and 12 months postoperatively that consisted of BCVA, refractive astigmatism (AS), central corneal thickness (CCT), IOP, and ECL. Secondary outcomes were adverse events related to the surgical procedure. With lower ECL and less adverse events, DALK was revealed to be beneficial over PK with similar visual outcomes. Results: There was no significant difference between the BCVA in the DALK and PK groups (at 6 months: 0.49 ± 0.17 vs. 0.48 ± 0.17; p = 0.48; at 12 months: 0.54 ± 0.17 vs. 0.52 ± 0.14; p = 0.41). The mean value of AS was significantly lower after the PK procedure when compared to DALK, after both 6 and 12 months of follow up (p < 0.001). The CCT in the DALK group was significantly lower when compared to the PK group (at 6 months: 452.1 ± 89.1 µm vs. 528.9 ± 69.9 µm, p < 0.0001; at 12 months: 451.6 ± 83.5 µm vs. 525.5 ± 37.1 µm). The endothelial cell loss at 12 months after surgery was significantly lower after DALK when compared to PK (p < 0.0001). DALK transplantation should be considered as an alternative procedure in the surgical treatment of keratoconus.


2021 ◽  
pp. 112067212198963
Author(s):  
Martina Menchini ◽  
Francesco Sartini ◽  
Filippo Tatti ◽  
Enrico Peiretti ◽  
Michele Figus

Purpose: To report a case of fully dislocated XEN Gel Implant device into the anterior chamber, 18 months after its implantation and its impact on endothelial cell density. Result: A 75-year-old man with a history of multiple glaucoma surgeries during the last three years presented with an entirely dislocated XEN Gel implant into the anterior chamber. An endothelial cell density reduction was observed over 18 months. Thus, the implant was removed. In the short-term after surgery, the endothelial cell loss rate reduced. Conclusion: XEN Gel Implant can dislocate into the anterior chamber, increasing endothelial cell loss in an eye already underwent multiple surgical procedures with subsequent adverse events. Therefore, if the implant seems displaced, the endothelial cell density should be monitored, and the length of the free-tube segment within the anterior chamber should be measured, during the patient’s follow-up.


Sign in / Sign up

Export Citation Format

Share Document