Application of transmission electron microscopes to nanometre-sized fabrication by means of electron beam-induced deposition

2004 ◽  
Vol 214 (1) ◽  
pp. 76-79 ◽  
Author(s):  
M. Shimojo ◽  
K. Mitsuishi ◽  
M. Tanaka ◽  
M. Han ◽  
K. Furuya
Author(s):  
G. Lehmpfuhl ◽  
P. J. Smith

Specimens being observed with electron-beam instruments are subject to contamination, which is due to polymerization of hydrocarbon molecules by the beam. This effect becomes more important as the size of the beam is reduced. In convergent-beam studies with a beam diameter of 100 Å, contamination was observed to grow on samples at very high rates. Within a few seconds needles began forming under the beam on both the top and the underside of the sample, at growth rates of 400-500 Å/s, severely limiting the time available for observation. Such contamination could cause serious difficulty in examining a sample with the new scanning transmission electron microscopes, in which the beam is focused to a few angstroms.We have been able to reduce the rate of contamination buildup by a combination of methods: placing an anticontamination cold trap in the sample region, preheating the sample before observation, and irradiating the sample with a large beam before observing it with a small beam.


Author(s):  
B. L. Armbruster ◽  
B. Kraus ◽  
M. Pan

One goal in electron microscopy of biological specimens is to improve the quality of data to equal the resolution capabilities of modem transmission electron microscopes. Radiation damage and beam- induced movement caused by charging of the sample, low image contrast at high resolution, and sensitivity to external vibration and drift in side entry specimen holders limit the effective resolution one can achieve. Several methods have been developed to address these limitations: cryomethods are widely employed to preserve and stabilize specimens against some of the adverse effects of the vacuum and electron beam irradiation, spot-scan imaging reduces charging and associated beam-induced movement, and energy-filtered imaging removes the “fog” caused by inelastic scattering of electrons which is particularly pronounced in thick specimens.Although most cryoholders can easily achieve a 3.4Å resolution specification, information perpendicular to the goniometer axis may be degraded due to vibration. Absolute drift after mechanical and thermal equilibration as well as drift after movement of a holder may cause loss of resolution in any direction.


2018 ◽  
Vol 9 ◽  
pp. 1220-1227 ◽  
Author(s):  
Caspar Haverkamp ◽  
George Sarau ◽  
Mikhail N Polyakov ◽  
Ivo Utke ◽  
Marcos V Puydinger dos Santos ◽  
...  

A fluorine free copper precursor, Cu(tbaoac)2 with the chemical sum formula CuC16O6H26 is introduced for focused electron beam induced deposition (FEBID). FEBID with 15 keV and 7 nA results in deposits with an atomic composition of Cu:O:C of approximately 1:1:2. Transmission electron microscopy proved that pure copper nanocrystals with sizes of up to around 15 nm were dispersed inside the carbonaceous matrix. Raman investigations revealed a high degree of amorphization of the carbonaceous matrix and showed hints for partial copper oxidation taking place selectively on the surfaces of the deposits. Optical transmission/reflection measurements of deposited pads showed a dielectric behavior of the material in the optical spectral range. The general behavior of the permittivity could be described by applying the Maxwell–Garnett mixing model to amorphous carbon and copper. The dielectric function measured from deposited pads was used to simulate the optical response of tip arrays fabricated out of the same precursor and showed good agreement with measurements. This paves the way for future plasmonic applications with copper-FEBID.


2014 ◽  
Vol 20 (2) ◽  
pp. 484-492 ◽  
Author(s):  
B. Layla Mehdi ◽  
Meng Gu ◽  
Lucas R. Parent ◽  
Wu Xu ◽  
Eduard N. Nasybulin ◽  
...  

AbstractThe recent development of in-situ liquid stages for (scanning) transmission electron microscopes now makes it possible for us to study the details of electrochemical processes under operando conditions. As electrochemical processes are complex, care must be taken to calibrate the system before any in-situ/operando observations. In addition, as the electron beam can cause effects that look similar to electrochemical processes at the electrolyte/electrode interface, an understanding of the role of the electron beam in modifying the operando observations must also be understood. In this paper we describe the design, assembly, and operation of an in-situ electrochemical cell, paying particular attention to the method for controlling and quantifying the experimental parameters. The use of this system is then demonstrated for the lithiation/delithiation of silicon nanowires.


2000 ◽  
Vol 6 (S2) ◽  
pp. 1142-1143
Author(s):  
Takaho Yoshida ◽  
Takeshi Kawasaki ◽  
Junji Endo ◽  
Tadao Furutsu ◽  
Isao Matsui ◽  
...  

Bright and coherent electron beams have been opening new frontiers in science and technology. So far, we have developed several field-emission transmission electron microscopes (FE-TEM) with increasing accelerating voltages to provide higher beam brightness. By using a 200-kV FE-TEM and electron holography techniques, we directly confirmed the Aharonov-Bohm effect. A 350-kV FE-TEM equipped with a low-temperature specimen stage enabled us to observe moving vortices in superconductors.2 Most Recently, we have developed a new 1-MV FE-TEM with a newly designed FE gun to obtain an even brighter and more coherent electron beam.Electron beam brightness, Br, defined in Figure 1, is suitable for measuring the performance of electron guns, since both lens aberrations and mechanical/electrical vibrations contribute to a decrease in beam brightness, and beam coherency is proportional to (Br)1/2. Therefore, we optimized design of the illuminating system and its operation by maximizing the electron beam brightness.