Methods to Monitor and Improve the Performance of Specimen Holders for Transmission Electron Cryomicroscopy

Author(s):  
B. L. Armbruster ◽  
B. Kraus ◽  
M. Pan

One goal in electron microscopy of biological specimens is to improve the quality of data to equal the resolution capabilities of modem transmission electron microscopes. Radiation damage and beam- induced movement caused by charging of the sample, low image contrast at high resolution, and sensitivity to external vibration and drift in side entry specimen holders limit the effective resolution one can achieve. Several methods have been developed to address these limitations: cryomethods are widely employed to preserve and stabilize specimens against some of the adverse effects of the vacuum and electron beam irradiation, spot-scan imaging reduces charging and associated beam-induced movement, and energy-filtered imaging removes the “fog” caused by inelastic scattering of electrons which is particularly pronounced in thick specimens.Although most cryoholders can easily achieve a 3.4Å resolution specification, information perpendicular to the goniometer axis may be degraded due to vibration. Absolute drift after mechanical and thermal equilibration as well as drift after movement of a holder may cause loss of resolution in any direction.

2005 ◽  
Vol 20 (7) ◽  
pp. 1785-1791 ◽  
Author(s):  
T. Vystavel ◽  
S.A. Koch ◽  
G. Palasantzas ◽  
J.Th.M. De Hosson

The structural stability of transition metal nanoclusters has been scrutinized with in situ transmission electron microscopy as a function of temperature. In particular iron, cobalt, niobium, and molybdenum clusters with diameters around 5 nm have been investigated. During exposure to air, a thin oxide shell with a thickness of 2 nm is formed around the iron and cobalt clusters, which is thermally unstable under moderate high vacuum annealing above 200 °C. Interestingly, niobium clusters oxidize only internally at higher temperatures without the formation of an oxide shell. They are unaffected under electron beam irradiation, whereas iron and cobalt undergo severe structural changes. Further, no cluster coalescence of niobium takes place, even during annealing up to 800 °C, whereas iron and cobalt clusters coalesce after decomposition of the oxide, as long as the clusters are in close contact. In contrast to niobium, molybdenum clusters do not oxidize upon annealing; they are stable under electron beam irradiation and coalesce at temperatures higher than 800 °C. In all cases, the coalescence process indicates a strong influence of the local environment of the cluster.


2002 ◽  
Vol 75 (4) ◽  
pp. 605-616 ◽  
Author(s):  
A. M. Shanmugharaj ◽  
Anil K. Bhowmick

Abstract Electron beam modification of carbon black (N220) and carbon-silica dual phase filler affects the microstructure of carbon black. This is confirmed from X-ray diffraction studies. The scanning electron microscopy /energy dispersive X-ray analysis reveals surface oxidation, which is further corroborated from nitrogen and iodine adsorptions. Transmission electron microscopy studies show the aggregation of fillers upon electron beam irradiation. Linear fractal dimension calculated by image analysis increases upon irradiation, due to the formation of filler aggregates.


Sign in / Sign up

Export Citation Format

Share Document