Use of MRI increases interobserver agreement on gross tumor volume for imaging‐diagnosed canine intracranial meningioma

2020 ◽  
Vol 61 (6) ◽  
pp. 726-737
Author(s):  
Celina Y. Morimoto ◽  
Cheryl L. Waldner ◽  
Vivian Fan ◽  
Narinder Sidhu ◽  
Quinn Matthews ◽  
...  
2020 ◽  
Vol 10 ◽  
Author(s):  
Simon K. B. Spohn ◽  
Maria Kramer ◽  
Selina Kiefer ◽  
Peter Bronsert ◽  
August Sigle ◽  
...  

PurposeAccurate contouring of intraprostatic gross tumor volume (GTV) is pivotal for successful delivery of focal therapies and for biopsy guidance in patients with primary prostate cancer (PCa). Contouring of GTVs, using 18-Fluor labeled tracer prostate specific membrane antigen positron emission tomography ([18F]PSMA-1007/PET) has not been examined yet.Patients and MethodsTen Patients with primary PCa who underwent [18F]PSMA-1007 PET followed by radical prostatectomy were prospectively enrolled. Coregistered histopathological gross tumor volume (GTV-Histo) was used as standard of reference. PSMA-PET images were contoured on two ways: (1) manual contouring with PET scaling SUVmin-max: 0–10 was performed by three teams with different levels of experience. Team 1 repeated contouring at a different time point, resulting in n = 4 manual contours. (2) Semi-automatic contouring approaches using SUVmax thresholds of 20–50% were performed. Interobserver agreement was assessed for manual contouring by calculating the Dice Similarity Coefficient (DSC) and for all approaches sensitivity, specificity were calculated by dividing the prostate in each CT slice into four equal quadrants under consideration of histopathology as standard of reference.ResultsManual contouring yielded an excellent interobserver agreement with a median DSC of 0.90 (range 0.87–0.94). Volumes derived from scaling SUVmin-max 0–10 showed no statistically significant difference from GTV-Histo and high sensitivities (median 87%, range 84–90%) and specificities (median 96%, range 96–100%). GTVs using semi-automatic segmentation applying a threshold of 20–40% of SUVmax showed no significant difference in absolute volumes to GTV-Histo, GTV-SUV50% was significantly smaller. Best performing semi-automatic contour (GTV-SUV20%) achieved high sensitivity (median 93%) and specificity (median 96%). There was no statistically significant difference to SUVmin-max 0–10.ConclusionManual contouring with PET scaling SUVmin-max 0–10 and semi-automatic contouring applying a threshold of 20% of SUVmax achieved high sensitivities and very high specificities and are recommended for [18F]PSMA-1007 PET based focal therapy approaches. Providing high specificities, semi-automatic approaches applying thresholds of 30–40% of SUVmax are recommend for biopsy guidance.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Xiao Chang ◽  
Wei Deng ◽  
Xin Wang ◽  
Zongmei Zhou ◽  
Jun Yang ◽  
...  

Abstract Purpose To investigate the interobserver variability (IOV) in target volume delineation of definitive radiotherapy for thoracic esophageal cancer (TEC) among cancer centers in China, and ultimately improve contouring consistency as much as possible to lay the foundation for multi-center prospective studies. Methods Sixteen cancer centers throughout China participated in this study. In Phase 1, three suitable cases with upper, middle, and lower TEC were chosen, and participants were asked to contour a group of gross tumor volume (GTV-T), nodal gross tumor volume (GTV-N) and clinical target volume (CTV) for each case based on their routine experience. In Phase 2, the same clinicians were instructed to follow a contouring protocol to re-contour another group of target volume. The variation of the target volume was analyzed and quantified using dice similarity coefficient (DSC). Results Sixteen clinicians provided routine volumes, whereas ten provided both routine and protocol volumes for each case. The IOV of routine GTV-N was the most striking in all cases, with the smallest DSC of 0.37 (95% CI 0.32–0.42), followed by CTV, whereas GTV-T showed high consistency. After following the protocol, the smallest DSC of GTV-N was improved to 0.64 (95% CI 0.45–0.83, P = 0.005) but the DSC of GTV-T and CTV remained constant in most cases. Conclusion Variability in target volume delineation was observed, but it could be significantly reduced and controlled using mandatory interventions.


2020 ◽  
Vol 152 ◽  
pp. S856-S857
Author(s):  
D. Lang ◽  
J.C. Peeken ◽  
M.B. Spraker ◽  
M.J. Nyflot ◽  
S.E. Combs ◽  
...  

2012 ◽  
Vol 53 (2) ◽  
pp. 338-341 ◽  
Author(s):  
Ryo TOYA ◽  
Ryuji MURAKAMI ◽  
Kuniyuki TASHIRO ◽  
Morikatsu YOSHIDA ◽  
Fumi SAKAMOTO ◽  
...  