Effect of Adiabatic Co-Planar Extension Surfaces on Wind-Related Solar-Collector Heat Transfer Coefficients

1981 ◽  
Vol 103 (2) ◽  
pp. 268-271 ◽  
Author(s):  
E. M. Sparrow ◽  
S. C. Lau

The heat transfer response to framing the thermally active cover surface of a flat plate solar collector with adiabatic co-planar extension surfaces has been investigated by wind tunnel experiments. Various framing patterns were employed (leading edge and/or trailing edge and/or side edge framing), along with frames of different width. The experiments were performed for various angles of inclination of the plate surface relative to the oncoming airstream and for a range of Reynolds numbers. It was found that the wind-related heat transfer coefficients can be substantially lower when the collector is framed than when it is unframed. An estimate of the possible reduction of the average heat transfer coefficient can be obtained from the equation h/h* = (Lc/Lf)1/2, where h and h* respectively denote the coefficients in the presence and in the absence of the frame. The quantity Lc is a dimension that is characteristic of the thermally active area of the cover surface, while Lf is a characteristic dimension of the outer edges of the frame. With respect to the reduction of the heat transfer coefficient, framing along the side edges appears to be more beneficial than framing along the leading and trailing edges, as is framing along the trailing edge compared with framing along the leading edge.

2001 ◽  
Vol 123 (4) ◽  
pp. 766-773 ◽  
Author(s):  
M. E. Taslim ◽  
Y. Pan ◽  
S. D. Spring

Airfoil leading-edge surfaces in state-of-the-art gas turbines, being exposed to very high gas temperatures, are often life-limiting locations and require complex cooling schemes for robust designs. A combination of convection and film cooling is used in conventional designs to maintain leading-edge metal temperatures at levels consistent with airfoil life requirements. Compatible with the external contour of the airfoil at the leading edge, the leading-edge cooling cavities often have complex cross-sectional shapes. Furthermore, to enhance the heat transfer coefficient in these cavities, they are often roughened on three walls with ribs of different geometries. The cooling flow for these geometries usually enters the cavity from the airfoil root and flows radially to the airfoil tip or, in the more advanced designs, enters the leading edge cavity from the adjacent cavity through a series of crossover holes in the wall separating the two cavities. In the latter case, the crossover jets impinge on a smooth leading-edge wall and exit through the showerhead film holes, gill film holes on the pressure and suction sides, and, in some cases, form a crossflow in the leading-edge cavity, which is ejected through the airfoil tip hole. The main objective of this investigation was to study the effects that film holes on the target surface have on the impingement heat transfer coefficient. Available data in the open literature are mostly for impingement on a flat smooth surface with no representation of the film holes. This investigation involved two new features used in airfoil leading-edge cooling, those being a curved and roughened target surface in conjunction with leading-edge row of film holes. Results of the crossover jets impinging on these leading-edge surface geometries with no film holes were reported by these authors previously. This paper reports experimental results of crossover jets impinging on those same geometries in the presence of film holes. The investigated surface geometries were smooth, roughened with large and small conical bumps as well as tapered radial ribs. A range of flow arrangements and jet Reynolds numbers were investigated, and the results were compared to those of the previous study where no film holes were present. It was concluded that the presence of leading-edge film holes along the leading edge enhances the internal impingement heat transfer coefficients significantly. The smaller conical bump geometry in this investigation produced impingement heat transfer coefficients up to 35 percent higher than those of the smooth target surface. When the contribution of the increased area in the overall heat transfer is taken into consideration, this same geometry for all flow cases as well as jet impingement distances Z/djet provides an increase in the heat removal from the target surface by as much as 95 percent when compared with the smooth target surface.


Author(s):  
M. E. Taslim ◽  
Y. Pan ◽  
S. D. Spring

Airfoil leading-edge surfaces in state-of-the-art gas turbines, being exposed to very high gas temperatures, are often life-limiting locations and require complex cooling schemes for robust designs. A combination of convection and film cooling is used in conventional designs to maintain leading-edge metal temperatures at levels consistent with airfoil life requirements. Compatible with the external contour of the airfoil at the leading edge, the leading-edge cooling cavities often have complex cross-sectional shapes. Furthermore, to enhance the heat transfer coefficient in these cavities, they are often roughened on three walls with ribs of different geometries. The cooling flow for these geometries usually enters the cavity from the airfoil root and flows radially to the airfoil tip or, in the more advanced designs, enters the leading edge cavity from the adjacent cavity through a series of crossover holes in the wall separating the two cavities. In the latter case, the crossover jets impinge on a smooth leading-edge wall and exit through the showerhead film holes, gill film holes on the pressure and suction sides, and, in some cases, forms a cross-flow in the leading-edge cavity and is ejected through the airfoil tip hole. The main objective of this investigation was to study the effects that film holes on the target surface have on the impingement heat transfer coefficient. Available data in the open literature are mostly for impingement on a flat smooth surface with no representation of the film holes. This investigation involved two new features used in airfoil leading-edge cooling those being a curved and roughened target surface in conjunction with leading-edge row of film holes. Results of the crossover jets impinging on these leading-edge surface geometries with no film holes were reported by these authors previously. This paper reports experimental results of crossover jets impinging on those same geometries in the presence of film holes. The investigated surface geometries were smooth, roughened with large and small conical bumps as well as tapered radial ribs. A range of flow arrangements and jet Reynolds numbers were investigated and the results were compared to those of the previous study were no film holes were present. It was concluded that the presence of leading-edge film holes along the leading edge enhances the internal impingement heat transfer coefficients significantly. The smaller conical bump geometry in this investigation produced impingement heat transfer coefficients up to 35% higher than those of the smooth target surface. When the contribution of the increased area in the overall heat transfer is taken into consideration, this same geometry for all flow cases as well as jet impingement distances (Z/djet) provides an increase in the heat removal from the target surface by as much as 95% when compared with the smooth target surface.


Author(s):  
Ann-Christin Fleer ◽  
Markus Richter ◽  
Roland Span

AbstractInvestigations of flow boiling in highly viscous fluids show that heat transfer mechanisms in such fluids are different from those in fluids of low viscosity like refrigerants or water. To gain a better understanding, a modified standard apparatus was developed; it was specifically designed for fluids of high viscosity up to 1000 Pa∙s and enables heat transfer measurements with a single horizontal test tube over a wide range of heat fluxes. Here, we present measurements of the heat transfer coefficient at pool boiling conditions in highly viscous binary mixtures of three different polydimethylsiloxanes (PDMS) and n-pentane, which is the volatile component in the mixture. Systematic measurements were carried out to investigate pool boiling in mixtures with a focus on the temperature, the viscosity of the non-volatile component and the fraction of the volatile component on the heat transfer coefficient. Furthermore, copper test tubes with polished and sanded surfaces were used to evaluate the influence of the surface structure on the heat transfer coefficient. The results show that viscosity and composition of the mixture have the strongest effect on the heat transfer coefficient in highly viscous mixtures, whereby the viscosity of the mixture depends on the base viscosity of the used PDMS, on the concentration of n-pentane in the mixture, and on the temperature. For nucleate boiling, the influence of the surface structure of the test tube is less pronounced than observed in boiling experiments with pure fluids of low viscosity, but the relative enhancement of the heat transfer coefficient is still significant. In particular for mixtures with high concentrations of the volatile component and at high pool temperature, heat transfer coefficients increase with heat flux until they reach a maximum. At further increased heat fluxes the heat transfer coefficients decrease again. Observed temperature differences between heating surface and pool are much larger than for boiling fluids with low viscosity. Temperature differences up to 137 K (for a mixture containing 5% n-pentane by mass at a heat flux of 13.6 kW/m2) were measured.


Author(s):  
Jatuporn Kaew-On ◽  
Somchai Wongwises

The evaporation heat transfer coefficients and pressure drops of R-410A and R-134a flowing through a horizontal-aluminium rectangular multiport mini-channel having a hydraulic diameter of 3.48 mm are experimentally investigated. The test runs are done at refrigerant mass fluxes ranging between 200 and 400 kg/m2s. The heat fluxes are between 5 and 14.25 kW/m2, and refrigerant saturation temperatures are between 10 and 30 °C. The effects of the refrigerant vapour quality, mass flux, saturation temperature and imposed heat flux on the measured heat transfer coefficient and pressure drop are investigated. The experimental data show that in the same conditions, the heat transfer coefficients of R-410A are about 20–50% higher than those of R-134a, whereas the pressure drops of R-410A are around 50–100% lower than those of R-134a. The new correlations for the evaporation heat transfer coefficient and pressure drop of R-410A and R-134a in a multiport mini-channel are proposed for practical applications.


1993 ◽  
Vol 115 (4) ◽  
pp. 231-236 ◽  
Author(s):  
V. B. Sharma ◽  
S. C. Mullick

An approximate method for calculation of the hourly output of a solar still over a 24-hour cycle has been studied. The hourly performance of a solar still is predicted given the values of the insolation, ambient temperature, wind heat-transfer coefficient, water depth, and the heat-transfer coefficient through base and sides. The proposed method does not require graphical constructions and does not assume constant heat-transfer coefficients as in the previous methods. The possibility of using the values of the heat-transfer coefficients for the preceding time interval in the heat balance equations is examined. In fact, two variants of the basic method of calculation are examined. The hourly rate of evaporation is obtained. The results are compared to those obtained by numerical solution of the complete set of heat balance equations. The errors from the approximate method in prediction of the 24-hour output are within ±1.5 percent of the values from the numerical solution using the heat balance equations. The range of variables covered is 5 to 15 cms in water depth, 0 to 3 W/m2K in a heat-transfer coefficient through base and sides, and 5 to 40 W/m2K in a wind heat-transfer coefficient.


Author(s):  
Nirm V. Nirmalan ◽  
Ronald S. Bunker ◽  
Carl R. Hedlung

A new method has been developed and demonstrated for the non-destructive, quantitative assessment of internal heat transfer coefficient distributions of cooled metallic turbine airfoils. The technique employs the acquisition of full-surface external surface temperature data in response to a thermal transient induced by internal heating/cooling, in conjunction with knowledge of the part wall thickness and geometry, material properties, and internal fluid temperatures. An imaging Infrared camera system is used to record the complete time history of the external surface temperature response during a transient initiated by the introduction of a convecting fluid through the cooling circuit of the part. The transient data obtained is combined with the cooling fluid network model to provide the boundary conditions for a finite element model representing the complete part geometry. A simple 1D lumped thermal capacitance model for each local wall position is used to provide a first estimate of the internal surface heat transfer coefficient distribution. A 3D inverse transient conduction model of the part is then executed with updated internal heat transfer coefficients until convergence is reached with the experimentally measured external wall temperatures as a function of time. This new technique makes possible the accurate quantification of full-surface internal heat transfer coefficient distributions for prototype and production metallic airfoils in a totally non-destructive and non-intrusive manner. The technique is equally applicable to other material types and other cooled/heated components.


2017 ◽  
Vol 15 (3) ◽  
pp. 467
Author(s):  
Ravinder Kumar Sahdev ◽  
Mahesh Kumar ◽  
Ashwani Kumar Dhingra

In this paper, convective and evaporative heat transfer coefficients of the Indian groundnut were computed under indoor forced convection drying (IFCD) mode. The groundnuts were dried as a single thin layer with the help of a laboratory dryer till the optimum safe moisture storage level of 8 – 10%. The experimental data were used to determine the values of experimental constants C and n in the Nusselt number expression by a simple linear regression analysis and consequently, the convective heat transfer coefficient (CHTC) was determined. The values of CHTC were used to calculate the evaporative heat transfer coefficient (EHTC). The average values of CHTC and EHTC were found to be 2.48 W/m2 oC and 35.08 W/m2 oC, respectively. The experimental error in terms of percent uncertainty was also estimated. The experimental error in terms of percent uncertainty was found to be 42.55%. The error bars for convective and evaporative heat transfer coefficients are also shown for the groundnut drying under IFCD condition.


2000 ◽  
Author(s):  
M. Kumagai ◽  
R. S. Amano ◽  
M. K. Jensen

Abstract A numerical and experimental investigation on cooling of a solid surface was performed by studying the behavior of an impinging jet onto a fixed flat target. The local heat transfer coefficient distributions on a plate with a constant heat flux were computationally investigated with a normally impinging axisymmetric jet for nozzle diameter of 4.6mm at H/d = 4 and 10, with the Reynolds numbers of 10,000 and 40,000. The two-dimensional cylindrical Navier-Stokes equations were solved using a two-equation k-ε turbulence model. The finite-volume differencing scheme was used to solve the thermal and flow fields. The predicted heat transfer coefficients were compared with experimental measurements. A universal function based on the wave equation was developed and applied to the heat transfer model to improve calculated local heat transfer coefficients for short nozzle-to-plate distance (H/d = 4). The differences between H/d = 4 and 10 due to the correlation among heat transfer coefficient, kinetic energy and pressure were investigated for the impingement region. Predictions by the present model show good agreement with the experimental data.


2000 ◽  
Author(s):  
Edward V. McAssey ◽  
Jinfeng Wu ◽  
Thomas Dougherty ◽  
Bao Wen Yang

Abstract Data are presented for sub-cooled boiling of water in the range of two to four atmospheres. The results show that the sharp increase in heat transfer coefficient associated with nucleate boiling occurs at wall superheats of 20 °C to 30 °C. Comparisons between experimental and predicted heat transfer coefficients are also presented. The two prediction methods examined are the Chen correlation and the Kandlikar correlation.


2014 ◽  
Vol 925 ◽  
pp. 625-629 ◽  
Author(s):  
C.S. Oon ◽  
A. Badarudin ◽  
S.N. Kazi ◽  
M. Fadhli

The heat transfer in annular heat exchanger with titanium oxide of 1.0 volume % concentration as the medium of heat exchanger is considered in this study. The heat transfer simulation of the flow is performed by using Computational Fluid Dynamics package, Ansys Fluent. The heat transfer coefficients of water to titanium oxide nanofluid flowing in a horizontal counter-flow heat exchanger under turbulent flow conditions are investigated. The results show that the convective heat transfer coefficient of the nanofluid is slightly higher than that of the base fluid by several percents. The heat transfer coefficient increases with the increase of the mass flow rate of hot water and also the nanofluid.


Sign in / Sign up

Export Citation Format

Share Document