scholarly journals Pressure Measurements in a Wire-Wrapped 61-Pin Hexagonal Fuel Bundle

2017 ◽  
Vol 140 (3) ◽  
Author(s):  
Rodolfo Vaghetto ◽  
Philip Jones ◽  
Nolan Goth ◽  
Mason Childs ◽  
Saye Lee ◽  
...  

To achieve longer-life liquid-metal fast reactor cores, designers are considering to increase the wall gap of the wire-wrapped hexagonal fuel bundles to account for volumetric void swelling and radiation creep. A new wire-wrapped hexagonal test bundle has been constructed, with a wall gap larger than prior experiments, and experimental pressure drop data have been generated under laminar, transition, and turbulent flow regimes (corresponding to Re of 250–19,000), to complement the existing database of small wall gap experimental bundles. The comparison of the experimental data set with the predictions of four existing correlations (Baxi and Dalle Donne, Cheng and Todreas detailed (CTD), Kirillov, and Rehme) showed general agreement between data and the selected correlations. However, the CTD correlation most accurately predicted the experimental trend and the transition between flow regimes. The analysis of the experimental data also revealed that the larger wall gap size caused a lower bundle pressure drop due to the increased bypass flow area.

Author(s):  
Christian Weinmu¨ller ◽  
Dimos Poulikakos

Microfluidics has experienced a significant increase in research activities in recent years with a wide range of applications emerging, such as micro heat exchangers, energy conversion devices, microreactors, lab-on-chip devices and micro total chemical analysis systems (μTAS). Efforts to enhance or extend the performance of single phase microfluidic devices are met by two-phase flow systems [1, 2]. Essential for the design and control of microfluidic systems is the understanding of the fluid/hydrodynamic behavior, especially pressure drop correlations. These are well established for single phase flow, however, analytical correlations for two-phase flow only reflect experimentally obtained values within an accuracy of ± 50% [3, 4]. The present study illustrates the effect of two-phase flow regimes on the pressure drop. Experimental measurement data is put into relation of calculated values based on established correlations of Lockhart-Martinelli with Chisholm modifications for macroscopic flows [5, 6] and Mishima-Hibiki modifications for microscale flows [7]. Further, the experimental pressure drop data is superimposed onto two-phase flow maps to identify apparent correlations of pressure drop abnormalities and flow regimes. The experiments were conducted in a square microchannel with a width of 200 μm. Optical access is guaranteed by an anodically bonded glass plate on a MEMS fabricated silicon chip. Superficial velocities range from 0.01 m/s to 1 m/s for the gas flow and from 0.0001 m/s to 1 m/s for the liquid flow with water as liquid feed and CO2 as gas. The analysis of the flow regimes was performed by imaging the distinct flow regimes by laser induced fluorescence microscopy, employing Rhodamine B as the photosensitive dye. The pressure drop was synchronically recorded with a 200 mbar, 2.5 bar and 25 bar differential pressure transmitter and the data was exported via a LabView based software environment, see Figure 1. Figure 2 illustrates the experimentally obtained pressure drop in comparison to the calculated values based on the Lockhard-Martinelli correlation with the Chisholm modification and the Mishima-Hibiki modification. For both cases the predications underestimate the two-phase pressure drop by more than 50%. Nevertheless, the regression of the experimental data has an offset of linear nature. Two-phase flow is assigned to flow regime maps of bubbly, wedging, slug or annular flow defined by superficial gas and liquid velocities. In Figure 3 the pressure drop is plotted as a surface over the corresponding flow regime map. Transition lines indicate a change of flow regimes enclosing an area of an anticline in the pressure data. In the direct comparison between the calculated and the measured values, the two surfaces show a distinct deviation. Especially, the anticline of the experimental data is not explained by the analytical correlations. Figure 4 depicts the findings of Figure 3 at a constant superficial velocity of 0.0232 m/s. The dominant influence of the flow regimes on the pressure drop becomes apparent, especially in the wedging flow regime. The evident deviation of two-phase flow correlations for the pressure drop is based on omitting the influence of the flow regimes. In conclusion, the study reveals a strong divergence of pressure drop measurements in microscale two-phase flow from established correlations of Lockhart-Martinelli and recognized modifications. In reference to [8, 9], an analytical model incorporating the flow regimes and, hence, predicting the precise pressure drop would be of great benefit for hydrodynamic considerations in microfluidics.


2008 ◽  
Vol 7 (2) ◽  
pp. 27
Author(s):  
C. Y. Nakashima ◽  
S. Oliveira Jr ◽  
E. F. Caetano

This paper presents a review of correlations used for pressure drop calculation in narrow annular clearances with rotation of inner cylinder. Based on these review, a new general correlation is proposed to calculate pressure drop through such clearances. Results are compared with experimental data for different flow regimes: laminar, laminar with Taylor vortex, smooth and rough turbulent, with good agreement. The main objective is to develop a simple and general correlation that could be used for backflow calculation in twin-screw multiphase pumps. In this kind of pump, the volumetric efficiency is defined mainly by the backflow rate which occurs in the annular clearance between screw and casing. Usually, the backflow is calculated ignoring the influence of shaft rotation over pressure drop and does not consider the several possible flow regimes. Depending on operational conditions, this simplification can lead to significant errors.


Author(s):  
Ting Xiong ◽  
Bo Wen ◽  
Yuanfeng Zan ◽  
Xiao Yan

In order to obtain the hydraulic resistance characteristics of steam generator (SG) tube support plates (TSP), experimental as well as CFD studies have been carried out on both the single-phase and two-phase hydraulic resistances of various trefoil or quatrefoil orifice plates. Results show that with the increase of the Renylod number, the single-phase pressure drop coefficient decreases firstly and remains almost constant later. The single-phase pressure drop coefficient decreases with the increase of the chamfer radius of orifice or flow area. The two-phase pressure drops predicted by the empirical correlations are generally larger than the experimental results, while the pressure drops predicted by CFD software agree with the experimental data.


2008 ◽  
Vol 130 (7) ◽  
Author(s):  
Ravi K. Duggirala ◽  
Christopher J. Roy ◽  
S. M. Saeidi ◽  
Jay M. Khodadadi ◽  
Don R. Cahela ◽  
...  

Three-dimensional computational fluid dynamics simulations are performed for the flow of air through microfibrous materials for void fractions of 0.41 and 0.47 and face velocities ranging between 0.04ms and 1.29m∕s. The microfibrous materials consist of activated carbon powder with diameters of 137×10−6m entrapped in a matrix of cylindrical fibers with diameters of 8×10−6m. These sintered microfibrous materials are a new class of patented materials with properties that are advantageous compared to traditional packed beds or monoliths. Microfibrous materials have demonstrated enhanced heat and mass transfer compared to packed beds of particles of similar dimensions. In this paper, the simulations are used to predict the pressure drop per unit length through the materials and to analyze the details of the flow that are difficult to interrogate experimentally. Various geometric approximations are employed in order to allow the simulations to be performed in an efficient manner. The Knudsen number, defined as the ratio of the mean free path between molecular collisions to the fiber diameter, is 0.011; thus, velocity-slip boundary conditions are employed and shown to have only a minor effect on the pressure drop predictions. Significant effort is made to estimate numerical errors associated with the discretization process, and these errors are shown to be negligible (less than 3%). The computational predictions for pressure drop are compared to available experimental data as well as to two theory-based correlations: Ergun’s equation and the porous media permeability equation. The agreement between the simulations and the experiments is within 30% and is reasonable considering the significant geometric approximations employed. The errors in the simulations and correlations with respect to experimental data exhibit the same trend with face velocity for both void fractions. This consistent trend suggests the presence of experimental bias errors that correlate with the face velocity. The simulations generally underpredict the experimental pressure drop for the low void fraction case and overpredict the experimental pressure drop for the high void fraction case.


1992 ◽  
Vol 6 (1-4) ◽  
pp. 257-301 ◽  
Author(s):  
Akimi Serizawa ◽  
Isao Kataoka ◽  
Itaru Michiyoshi