scholarly journals Experimental Study of the Effects of Bleed Holes on Heat Transfer and Pressure Drop in Trapezoidal Passages With Tapered Turbulators

1993 ◽  
Author(s):  
M. E. Taslim ◽  
T. Li ◽  
S. D. Spring

Trailing edge cooling cavities in modern gas turbine blades often have trapezoidal cross-sectional areas of relatively low aspect ratio. To enhance cooling effectiveness in these passages, they are roughened with tapered turbulators. Furthermore, to provide additional cooling for the trailing edge, the cooling air may be ejected through trailing edge slots as it moves radially along the cooling passage. The tapered turbulators, in conjunction with the presence of these slots along the smaller base of the trapezoidal cavity, create spanwise as well as longitudinal variations in heat transfer coefficient on the turbulated walls. Moreover, the continuous variation of cooling air velocity along these passages causes a continuous change in static pressure which also requires investigation. Liquid crystals are used in this experimental investigation to study the effects of tapered turbulators on heat transfer coefficients in trailing edge passages with and without bleed holes. The tapered turbulators are configured on two opposite walls of the trapezoidal test section in a staggered arrangement with an angle of attack to the mainstream flow, α, of 90°. Nine different test geometries consisting of two passage aspect ratios, AR, were tested over a range of turbulator aspect ratios, ARt, blockage ratios, emax/Dh, pitch-to-height ratios, S/emax, and Reynolds numbers. Channel pressure losses were also measured and both heat transfer and friction factor results for several geometries are compared. It is concluded that a) there exists a large spanwise variation in heat transfer coefficient in test sections with no bleed holes, b) adding bleed holes to the smaller base of the trapezoidal cavity gives a spanwise velocity component to the mainstream flow and reduces this variation, and c) Nusselt numbers measured in the test sections with bleed holes correlate well with local Reynolds number.

1995 ◽  
Vol 117 (2) ◽  
pp. 281-289 ◽  
Author(s):  
M. E. Taslim ◽  
T. Li ◽  
S. D. Spring

Trailing edge cooling cavities in modern gas turbine blades often have trapezoidal cross-sectional areas of relatively low aspect ratio. To enhance cooling effectiveness in these passages, they are roughened with tapered turbulators. Furthermore, to provide additional cooling for the trailing edge, the cooling air may be ejected through trailing edge slots as it moves radially along the cooling passage. The tapered turbulators, in conjunction with the presence of these slots along the smaller base of the trapezoidal cavity, create both spanwise and longitudinal variations in heat transfer coefficient on the turbulated walls. Moreover, the continuous variation of cooling air velocity along these passages causes a continuous change in static pressure, which also requires investigation. Liquid crystals are used in this experimental investigation to study the effects of tapered turbulators on heat transfer coefficients in trailing edge passages with and without bleed holes. The tapered turbulators are configured on two opposite walls of the trapezoidal test section in a staggered arrangement with an angle of attack to the mainstream flow, α, of 90 deg. Nine different test geometries consisting of two passage aspect ratios, AR, were tested over a range of turbulator aspect ratios, ARt, blockage ratios, emax/Dh, pitch-to-height ratios, S/emax, and Reynolds numbers. Channel pressure losses were also measured and both heat transfer and friction factor results for several geometries are compared. It is concluded that (a) there exists a large spanwise variation in heat transfer coefficient in test sections with no bleed holes, (b) adding bleed holes to the smaller base of the trapezoidal cavity gives a spanwise velocity component to the mainstream flow and reduces this variation, and (c) Nusselt numbers measured in the test sections with bleed holes correlate well with local Reynolds number.


1991 ◽  
Vol 113 (3) ◽  
pp. 346-353 ◽  
Author(s):  
M. E. Taslim ◽  
L. A. Bondi ◽  
D. M. Kercher

Turbine blade cooling is imperative in advanced aircraft engines. The extremely hot gases that operate within the turbine section require turbine blades to be cooled by a complex cooling circuit. This cooling arrangement increases engine efficiency and ensures blade materials a longer creep life. One principle aspect of the circuit involves serpentine internal cooling passes throughout the core of the blade. Roughening the inside surfaces of these cooling passages with turbulence promoters provides enhanced heat transfer rates from the surface. The purpose of this investigation was to study the effect of rotation, aspect ratio, and turbulator roughness on heat transfer in these rib-roughened passages. The investigation was performed in an orthogonally rotating setup to simulate the actual rotation of the cooling passages. Single-pass channels, roughened on two opposite walls, with turbulators positioned at 45 deg angle to the flow, in a criss-cross arrangement, were studied throughout this experiment. The ribs were arranged such that their pitch-to-height ratio remained at a constant value of 10. An aspect ratio of unity was investigated under three different rib blockage ratios (turbulator height/channel hydraulic diameter) of 0.1333, 0.25, and 0.3333. A channel with an aspect ratio of 2 was also investigated for a blockage ratio of 0.25. Air was flown radially outward over a Reynolds number range of 15,000 to 50,000. The rotation number was varied from 0 to 0.3. Stationary and rotating cases of identical geometries were compared. Results indicated that rotational effects are more pronounced in turbulated passages of high aspect and low blockage ratios for which a steady increase in heat transfer coefficient is observed on the trailing side as rotation number increases while the heat transfer coefficient on the leading side shows a steady decrease with rotation number. However, the all-smooth-wall classical pattern of heat transfer coefficient variation on the leading and trailing sides is not followed for smaller aspect ratios and high blockage ratios when the relative artificial roughness is high.


2001 ◽  
Author(s):  
M. K. Chyu ◽  
O. B. Ojo ◽  
C. H. Yen ◽  
R. S. Nordlund

Abstract An innovative design of closed-loop cooling system for a stator airfoil consists of a number of internal cooling passages wrapping around both pressure and suction sides of the airfoil. The cooling passages feature (1) jet impingement post a sharp 90-degree turn at the passage inlet, (2) turbulators on the outermost wall, and (3) a nearly 180-degree turn in the trailing edge. In addition, the passage has an irregular cross-section and varies throughout its entire length. A series of heat transfer tests have been performed at Re = 17,000 ∼ 61,000, compared to this tests which uses a new approach, so-called the hybrid liquid crystal technique. The magnitude of local heat transfer coefficient rises sharply in three regions. The first maximum occurs in the region subjected to direct jet impingement as the flow turns into the channel. Compounded with the inlet effect, this maximum, in fact, is the highest heat transfer coefficient over the entire passage. The second and third peaks, both are comparable in magnitude, locate near the trailing edge of the airfoil where the flow experiences a 180-degree turn and near the passage exit with a 90-degree turn. The average value of heat transfer coefficient over the entire passage is about 1.9∼ 2.5 times higher than that with fully developed turbulent flow in a straight channel. This level of enhancement is comparable to that of the conventional ribturbulators with a 90-degree angle-of-attack.


Author(s):  
M. E. Taslim ◽  
L. A. Bondi ◽  
D. M. Kercher

Turbine blade cooling is imperative in advanced aircraft engines. The extremely hot gases that operate within the turbine section require turbine blades to be cooled by a complex cooling circuit. This cooling arrangement increases engine efficiency and ensures blade materials a longer creep life. One principle aspect of the circuit involves serpentine internal cooling passes throughout the core of the blade. Roughening the inside surfaces of these cooling passages with turbulence promoters provides enhanced heat transfer rates from the surface. The purpose of this investigation was to study the effects of rotation, aspect ratio, and turbulator roughness on heat transfer in these rib-roughened passage. The investigation was performed in an orthogonally rotating setup to simulate the actual rotation of the cooling passages. Single pass channels, roughened on two opposite walls, with turbulators positioned at a 45° angle to the flow, in a criss-cross arrangement, were studied throughout this experiment. The ribs were arranged such that their pitch-to-height ratio remained at a constant value of 10. An aspect ratio of unity was investigated under three different rib blockage ratios (turbulator height/channel hydraulic diameter) of 0.1333, 0.25, and 0.3333. A channel with an aspect ratio of 2 was also investigated for a blockage ratio of 0.25. Air was flown radially outward over a Reynolds number range of 15000 to 50000. Rotation number was varied from 0 to 0.3. Stationary and rotating cases of identical geometries were compared. Results indicate that rotational effects are more pronounced in turbulated passages of high aspect and low blockage ratios for which a steady increase in heat transfer coefficient is observed on the trailing side as rotation number increases while the heat transfer coefficient on the leading side shows a steady decrease with rotation number. However, the all-smooth-wall classical pattern of heat transfer coefficient variation on the leading and trailing sides is not followed for smaller aspect ratios and high blockage ratios when the relative artificial roughness is high.


Author(s):  
Vijay K. Garg ◽  
Ali A. Ameri

A three-dimensional Navier-Stokes code has been used to compute the heat transfer coefficient on two film-cooled turbine blades, namely the VKI rotor with six rows of cooling holes including three rows on the shower head, and the C3X vane with nine rows of holes including five rows on the shower head. Predictions of heat transfer coefficient at the blade surface using three two-equation turbulence models, specifically, Coakley’s q-ω model, Chien’s k-ε model and Wilcox’s k-ω model with Menter’s modifications, have been compared with the experimental data of Camci and Arts (1990) for the VKI rotor, and of Hylton et al. (1988) for the C3X vane along with predictions using the Baldwin-Lomax (B-L) model taken from Garg and Gaugler (1995). It is found that for the cases considered here the two-equation models predict the blade heat transfer somewhat better than the B-L model except immediately downstream of the film-cooling holes on the suction surface of the VKI rotor, and over most of the suction surface of the C3X vane. However, all two-equation models require 40% more computer core than the B-L model for solution, and while the q-ω and k-ε models need 40% more computer time than the B-L model, the k-ω model requires at least 65% more time due to slower rate of convergence. It is found that the heat transfer coefficient exhibits a strong spanwise as well as streamwise variation for both blades and all turbulence models.


1998 ◽  
Vol 120 (4) ◽  
pp. 831-838 ◽  
Author(s):  
M. E. Taslim ◽  
G. J. Korotky

Cooling channels, roughened with repeated ribs, are commonly employed as a means of cooling turbine blades. The increased level of mixing induced by these ribs enhances the convective heat transfer in the blade cooling cavities. Many previous investigations have focused on the heat transfer coefficient on the surfaces between these ribs and only a few studies report the heat transfer coefficient on the rib surfaces themselves. The present study investigated the heat transfer coefficient on the surfaces of round-corner, low-aspect-ratio (ARrib = 0.667) ribs. Twelve rib geometries, comprising three rib height-to-channel hydraulic diameters (blockage ratios) of 0.133, 0.167, and 0.25 as well as three rib spacings (pitch-to-height ratios) of 5, 8.5, and 10 were investigated for two distinct thermal boundary conditions of heated and unheated channel walls. A square channel, roughened with low-aspect-ratio ribs on two opposite walls in a staggered manner and perpendicular to the flow direction, was tested. An instrumented copper rib was positioned either in the middle of the rib arrangements or in the furthest upstream location. Both rib heat transfer coefficient and channel friction factor for these low-aspect-ratio ribs were also compared with those of square ribs, reported previously by the authors. Heat transfer coefficients of the furthest upstream rib and that of a typical rib located in the middle of the rib-roughened region of the passage wall were also compared.


Author(s):  
Shuping P. Chen ◽  
Peiwen W. Li ◽  
Minking K. Chyu ◽  
Frank J. Cunha ◽  
William Abdel-Messeh

Described in this paper is an experimental study of heat transfer over a trailing edge configuration preceded with an internal cooling channel of pedestal array. The pedestal array consists of both circular pedestals and oblong shaped blocks. Downstream to the pedestal array, the trailing edge features pressure side cutback partitioned by the oblong shaped blocks. The local heat transfer coefficient over the entire wetted surface in the internal cooling chamber has been determined by using a “hybrid” measurement technique based on transient liquid crystal imaging. The hybrid technique employs the transient conduction model in a semi-infinite solid for resolving the heat transfer coefficient on the endwall surface uncovered by the pedestals. The heat transfer coefficient over a pedestal can be resolved by the lumped capacitance method with an assumption of low Biot number. The overall heat transfer for both the pedestals and endwalls combined shows a significant enhancement compared to the case with thermally developed smooth channel. Near the downstream most section of the suction side, the land, due to pressure side cutback, is exposed to the stream mixed with hot gas and discharged coolant. Both the adiabatic effectiveness and heat transfer coefficient on the land section are characterized by using the transient liquid crystal technique.


Author(s):  
Srivatsan Madhavan ◽  
Kishore Ranganath Ramakrishnan ◽  
Prashant Singh ◽  
Srinath V. Ekkad

Abstract Jet impingement is a cooling technique commonly employed in combustor liner cooling and high-pressure gas turbine blades. However, jets from upstream impingement holes reduce the effectiveness of downstream jets due to jet deflection in the direction of crossflow. In order to avoid this phenomenon and provide an enhanced cooling on the target surface, we have attempted to come up with a novel design called “crossflow diverters”. Crossflow diverters are U-shaped ribs that are placed between jets in the crossflow direction (under maximum crossflow condition). In this study, the baseline case is jet impingement onto a smooth surface with 10 rows of jet impingement holes, jet-to-jet spacing of X/D = Y/D = 6 and jet-to-target spacing of Z/D = 2. Crossflow diverters with thickness ‘t’ of 1.5875 mm, height ‘h’ of 2D placed in the streamwise direction at a distance of X = 2D from center of the jet have been investigated experimentally. Transient liquid crystal thermography technique has been used to obtain detailed measurement of heat transfer coefficient for four jet diameter based Reynolds numbers of 3500, 5000, 7500, 12000. It has been observed that crossflow diverters protect the downstream jets from upstream jet deflection thereby maximizing their stagnation cooling potential. An average of 15–30% enhancement in Nusselt number is obtained over the flow range tested. However, this comes at the expense of increase in pumping power. Pressure drop for the enhanced geometry is 1–1.5 times the pressure drop for baseline impingement case. At a constant pumping power, crossflow diverters produce 9–15% enhancement in heat transfer coefficient as compared to baseline smooth case.


2012 ◽  
Vol 135 (2) ◽  
Author(s):  
Sin Chien Siw ◽  
Minking K. Chyu ◽  
Mary Anne Alvin

An experimental study is performed to investigate the heat transfer characteristics and frictional losses in a rib roughened channel combined with detached pin-fins. The overall channel geometry (W = 76.2 mm, E = 25.4 mm) simulates an internal cooling passage of wide aspect ratio (3:1) in a gas turbine airfoil. With a given pin diameter, D = 6.35 mm = [1/4]E, three different pin-fin height-to-diameter ratios, H/D = 4, 3, and 2, were examined. Each of these three cases corresponds to a specific pin array geometry of detachment spacing (C) between the pin-tip and one of the endwalls, i.e., C/D = 0, 1, 2, respectively. The rib height-to-channel height ratio is 0.0625. Two newly proposed cross ribs, namely the broken rib and full rib are evaluated in this effort. The broken ribs are positioned in between two consecutive rows of pin-fins, while the full ribs are fully extended adjacent to the pin-fins. The Reynolds number, based on the hydraulic diameter of the unobstructed cross section and the mean bulk velocity, ranges from 10,000 to 25,000. The experiment employs a hybrid technique based on transient liquid crystal imaging to obtain distributions of the local heat transfer coefficient over all of the participating surfaces, including the endwalls and all pin elements. The presence of ribs enhances local heat transfer coefficient on the endwall substantially by approximately 20% to 50% as compared to the neighboring endwall. In addition, affected by the rib geometry, which is a relatively low profile as compared to the overall height of the channel, the pressure loss seems to be insensitive to the presence of the ribs. However, from the overall heat transfer enhancement standpoint, the baseline cases (without ribs) outperform cases with broken ribs or full ribs.


Author(s):  
Zhao Liu ◽  
Zhenping Feng ◽  
Liming Song

In this paper a numerical simulation is performed to predict the swirl cooling on internal leading edge cooling passage model. The relative performances of four kinds of turbulence models including the standard κ-ε model, the RNG κ-ε model, the standard κ-ω model and the SST κ-ω model in the simulation of the swirl flow by tangential inlet jets in a circular pipe are compared with available experimental data. The results show that SST κ-ω model is the best one based on simulation accuracy. Then the SST κ-ω model is adopted for the present simulation. A circular pipe with a single rectangular tangential inlet jet or with two rectangular tangential inlet jets is adopted to investigate the swirl cooling and its effectiveness. The influence of the Reynolds number and the inlet to wall temperature ratio are investigated. The results indicate that the heat transfer coefficient on the swirl chamber increases with the increase of Reynolds number, and increases with the decrease of the inlet to wall temperature ratio. The swirl pipe with two tangential inlets could get a heat transfer enhancement of about three times to that of the nonswirling pipe, while swirl pipe with one tangential inlet could get a heat transfer coefficient 38% higher than that of the nonswirling pipe.