Coupled Blowing and Suction for Flow Separation Control

Author(s):  
M. Tadjfar ◽  
D. J. Kamari

Abstract The effects of applying a coupled unsteady blowing and suction combination over SD7003 airfoil at Reynolds number of 60,000 at an angle of attack of 13°, where a large separation on the suction side of the airfoil existed, was considered to investigate active flow control (AFC) mechanism. URANS equations were employed to solve the flow field and k–ω SST was used as the turbulence model. The unsteady blowing and suction were implemented at an angle to the surface crossing the boundary layer (CBL). The influence of location and frequency of the blowing/suction jets were examined.

Author(s):  
Julia Kurz ◽  
Reinhard Niehuis

One application method of active flow control is the exploitation of the interaction between transition and flow separation on a profile. As turbulent flows are able to withstand higher adverse pressure gradients the enforcement of the transition process can be utilized to prevent or to reduce flow separation. This paper focuses on gaining a better understanding of high frequency active flow control (AFC) by fluidic oscillators and its influence on the transition process for a separated boundary layer. Flow control is applied on a highly loaded turbine exit case (TEC) profile which was in particular designed for this application. The profile is investigated in the high-speed cascade wind tunnel at the Bundeswehr University Munich. Significant loss reduction by AFC could be observed by total pressure loss determination in the low Reynolds number regime. In order to gain a better understanding of development of the suction side boundary layer, several boundary layer profiles are determined by hot-wire measurements at six axial positions on the suction side of the profile. Differences between the boundary layer development and the extent of the separation can be detected. Furthermore, a stability analysis of the boundary layer upstream of separation is conducted and compared to the measured frequency spectra.


Author(s):  
Sertac Cadirci ◽  
Hasan Gunes

An oscillatory, zero-net-mass flux actuator system, Jet and Vortex Actuator (JaVA), is implemented on the step wall of a backward facing step. JaVA is shown previously both experimentally and numerically that it can energize the boundary layer by creating jets or vortices thus it may delay flow separation when used properly. The main part of JaVA is a rectangular cavity with a moving actuator plate. The actuator plate is mounted asymmetrically inside the cavity of the JaVA box, such that there are one narrow and one wide gap between the plate and the box. The main governing parameters are the actuator plate’s width (b), the amplitude (a) and the operating frequency (f). The main target of the control with active jets on the step wall is to influence directly the main recirculation zone, thus as the actuator plate or the step’s vertical wall moves periodically in horizontal direction, a jet emerges into the recirculation zone. Non-dimensional numbers such as the scaled amplitude (Sa = 2πa/b) and the jet Reynolds number (ReJ = 4abf/ν) as well as the maximum cross flow velocity characterize the JaVA-induced flow types and effects on the recirculation zone. One period consists of one blowing and one suction phase into the recirculation zone. The actuator plate has a sinusoidal motion determined by the amplitude and the operating frequency. Time-averaged flow fields and boundary layer profiles for actuated and not actuated cases at various operating frequencies indicate the effect of active flow control. The control effectiveness is given by the ratio of the jet Reynolds number to the Reynolds number of the incoming flow (r = ReJ/Re). A transient finite-volume-based laminar, incompressible Navier-Stokes solver (Fluent) has been used to study the flow fields generated by JaVA. The computational domain consists of a moving zone along the channel and the motion of the actuator plate is generated by a moving grid imposing appropriate boundary conditions with User-Defined-Functions (UDF). Numerical simulations reveal the JaVA-boundary layer interaction in the narrow channel for various governing parameters such as frequencies (jet Reynolds numbers) and channel flow velocities (Reynolds numbers, Re = 200, 400 and 800). The proposed control method based on suction and blowing with an oscillating backward facing step (OsBFS) seems to be effective in shortening the recirculation zone length and delaying the flow separation downstream of the backward facing step.


2019 ◽  
Vol 11 (4) ◽  
pp. 823-836 ◽  
Author(s):  
J. P. Rosenblum ◽  
P. Vrchota ◽  
A. Prachar ◽  
S. H. Peng ◽  
S. Wallin ◽  
...  

Author(s):  
Marcel Staats ◽  
Wolfgang Nitsche

We present results of experiments on a periodically unsteady compressor stator flow of the type which would be expected in consequence of pulsed combustion. A Reynolds number of Re = 600000 was used for the investigations. The experiments were conducted on the two-dimensional low-speed compressor testing facility in Berlin. A choking device downstream the trailing edges induced a periodic non-steady outflow condition to each stator vane which simulated the impact of a pressure gaining combuster downstream from the last stator. The Strouhal number of the periodic disturbance was Sr = 0.03 w.r.t. the stator chord length. Due to the periodic non-steady outflow condition, the flow-field suffers from periodic flow separation phenomena, which were managed by means of active flow control. In our case, active control of the corner separation was applied using fluidic actuators based on the principle of fluidic amplification. The flow separation on the centre region of the stator blade was suppressed by means of a fluidic blade actuator leading to an overall time-averaged loss reduction of 11.5%, increasing the static pressure recovery by 6.8% while operating in the non-steady regime. Pressure measurements on the stator blade and the wake as well as PIV data proved the beneficial effect of the active flow control application to the flow field and the improvement of the compressor characteristics. The actuation efficiency was evaluated by two figures of merit introduced in this contribution.


Author(s):  
Valentin Bettrich ◽  
Martin Bitter ◽  
Reinhard Niehuis

The use of fluidic oscillators for active flow control applications is a proven and efficient concept. For the well-known highly loaded LP turbine profile T161, the total pressure losses could already reduced by 40% at low Reynolds numbers, were usually flow separation occurs. For further improvements of the active flow control concept, it is essential to understand the driving flow phenomena responsible for the loss reduction mechanism, which are discussed in this paper. The results presented are based on experimental investigations on a flat plate with pressure gradient, imposed with an aerodynamically highly loaded low pressure turbine suction side flow and equipped with active flow control. The analogy to the suction side of the T161 is shown and validated against former cascade measurements. Based on the T161 equivalent operating point of Re = 70,000 and a theoretical out flow Mach number of Ma2,th = 0.6, the focus is set on the interaction of the boundary layer flow with high frequency actuation. The chosen actuator, a high frequency coupled fluidic oscillator, is designed to independently adjust mass flow and frequency. The flat plate is equipped with an array of high frequency actuators to control the flow separation. For this study one oscillator operating point at 6.7kHz is presented and the influence on transition and loss reduction compared to the non-actuated case is discussed. This oscillator operating point was found to be most efficient and the steady and unsteady mixing behavior of the high frequency actuator impact and the low pressure turbine like suction side boundary layer flow is investigated in much detail. Depending on the measurement technique, the isentropic Mach number distribution, frequency spectra, standard deviation, skewness and kurtosis are evaluated. The most important results are on the one hand, that the chosen concept is more efficient compared to former studies in means of mass flow investment, which is mainly based on the chosen oscillator outlet position and frequency. On the other hand, in a transonic flow the mixing and interaction of the high frequency pulses and the boundary layer flow require about 10% of the surface length to even establish and about to 30% to be completed. These results of the mixing behavior between actuator and boundary layer for compressible flow conditions help to attain a fundamental understanding for future designs of active flow control concepts.


Sign in / Sign up

Export Citation Format

Share Document