Effects of Off-Design Operating Conditions on the Blade Row Interaction in a HP Turbine Stage

Author(s):  
G. Persico ◽  
P. Gaetani ◽  
C. Osnaghi

An extensive experimental analysis on the subject of the unsteady periodic flow in a highly subsonic HP turbine stage has been carried out at the Laboratorio di Fluidodinamica delle Macchine (LFM) of the Politecnico di Milano (Italy). In this paper the blade row interaction is progressively enforced by increasing the stator and rotor blade loading and by reducing the stator-rotor axial gap from 100% (very large to smooth the rotor inlet unsteadiness) to 35% (design configuration) of the stator axial chord. The time-averaged three-dimensional flow field in the stator-rotor gap was investigated by means of a conventional five-hole probe for the nominal (0°) and an highly positive (+22°) stator incidences. The evolution of the viscous flow structures downstream of the stator is presented to characterize the rotor incoming flow. The blade row interaction was evaluated on the basis of unsteady aerodynamic measurements at the rotor exit, performed with a fast-response aerodynamic pressure probe. Results show a strong dependence of the time-averaged and phase-resolved flow field and of the stage performance on the stator incidence. The structure of the vortex-blade interaction changes significantly as the magnitude of the rotor inlet vortices increases, and very different residual traces of the stator secondary flows are found downstream of the rotor. On the contrary, the increase of rotor loading enhances the unsteadiness in the rotor secondary flows but has a little effect on the vortex-vortex interaction. For the large axial gap, a reduction of stator-related effects at the rotor exit is encountered when the stator incidence is increased as a result of the different mixing rate within the cascade gap.

2009 ◽  
Vol 131 (3) ◽  
Author(s):  
G. Persico ◽  
P. Gaetani ◽  
C. Osnaghi

An extensive experimental analysis on the subject of the unsteady periodic flow in a high subsonic high pressure (HP) turbine stage has been carried out at the Laboratorio di Fluidodinamica delle Macchine of the Politecnico di Milano (Italy). In this paper the aerodynamic blade row interaction in HP turbines, enforced by increasing the stator and rotor blade loading and by reducing the stator-rotor axial gap, is studied in detail. The time-averaged three-dimensional flowfield in the stator-rotor gap was investigated by means of a conventional five-hole probe for the nominal (0 deg) and highly positive (+22 deg) stator incidences. The evolution of the viscous flow structures downstream of the stator is presented to characterize the rotor incoming flow. The blade row interaction was evaluated on the basis of unsteady aerodynamic measurements at the rotor exit, performed with a fast-response aerodynamic pressure probe. Results show a strong dependence of the time-averaged and phase-resolved flowfield and of the stage performance on the stator incidence. The structure of the vortex-blade interaction changes significantly as the magnitude of the rotor-inlet vortices increases, and very different residual traces of the stator secondary flows are found downstream of the rotor. On the contrary, the increase in rotor loading enhances the unsteadiness in the rotor secondary flows but has a little effect on the vortex-vortex interaction. For the large axial gap, a reduction of stator-related effects at the rotor exit is encountered when the stator incidence is increased as a result of the different mixing rate within the cascade gap.


Author(s):  
Davide Lengani ◽  
Cornelia Santner ◽  
Rosario Spataro ◽  
Berardo Paradiso ◽  
Emil Göttlich

The paper presents an experimental investigation of the unsteady flow field in the two-spool counter-rotating transonic turbine at Graz University of Technology. The test setup consists of a high pressure (HP) stage, a diffusing mid turbine frame with turning struts (TMTF) and a shrouded low pressure (LP) rotor. The two rotors are mounted on mechanically independent shafts in order to provide engine-representative operating conditions. The rig was designed in cooperation with MTU Aero Engines and Volvo Aero within the EU project DREAM (ValiDation of Radical Engine Architecture SysteMs). A two-sensor fast response aerodynamic pressure probe (2S-FRAP) has been employed to provide time-resolved aerodynamic area traverses downstream of the LP turbine. Such measurement allows estimating the total deterministic unsteadiness transported through the duct. In particular, it has been possible to isolate the structures induced by each rotor by means of the encoders mounted on the two shafts. A global ensemble averaged field, which takes into account the rotor-rotor interactions, is also provided. The time resolved distributions of the flow quantities are then discussed in details. The perturbations due to the HP rotor in terms of velocity and flow angle are negligible in this downstream plane. Indeed, the largest fluctuations of velocity are due to the TMTF-LP rotor interaction, they occur in the wake and secondary flows of the TMTF. Large fluctuations of static and total pressure are instead due to both rotors to the same extent.


Author(s):  
P. Gaetani ◽  
G. Persico ◽  
V. Dossena ◽  
C. Osnaghi

An extensive experimental analysis was carried out at Politecnico di Milano on the subject of unsteady flow in high pressure (HP) turbine stages. In this paper the unsteady flow measured downstream of a modern HP turbine stage is discussed. Traverses in two planes downstream of the rotor are considered and, in one of them, the effects of two very different axial gaps are investigated: the maximum axial gap, equal to one stator axial chord, is chosen to “switch off” the rotor inlet unsteadiness, while the nominal gap, equal to 1/3 of the stator axial chord, is representative of actual engines. The experiments were performed by means of a fast-response pressure probe, allowing for two-dimensional phase-resolved flow measurements in a bandwidth of 80 kHz. The main properties of the probe and the data processing are described. The core of the paper is the analysis of the unsteady rotor aerodynamics; for this purpose, instantaneous snapshots of the rotor flow in the relative frame are used. The rotor mean flow and its interaction with the stator wakes and vortices are also described. In the outer part of the channel only the rotor cascade effects can be observed, with a dominant role played by the tip-leakage flow and by the rotor tip passage vortex. In the hub region, where the secondary flows downstream of the stator are stronger, the persistence of stator vortices is slightly visible in the maximum stator-rotor axial gap configuration, while in the minimum stator-rotor axial gap configuration the interaction with the rotor vortices dominates the flow field. A fair agreement with the wakes and vortices transport models has been achieved. A discussion of the interaction process is reported giving particular emphasis to the effects of the different cascade axial gaps. Some final considerations on the effects of the different axial gap over the stage performances are reported.


2009 ◽  
Vol 132 (1) ◽  
Author(s):  
O. Schennach ◽  
J. Woisetschläger ◽  
B. Paradiso ◽  
G. Persico ◽  
P. Gaetani

This paper presents an experimental investigation of the flow field in a high-pressure transonic turbine with a downstream vane row (1.5 stage machine) concerning the airfoil indexing. The objective is a detailed analysis of the three-dimensional aerodynamics of the second vane for different clocking positions. To give an overview of the time-averaged flow field, five-hole probe measurements were performed upstream and downstream of the second stator. Furthermore in these planes additional unsteady measurements were carried out with laser Doppler velocimetry in order to record rotor phase-resolved velocity, flow angle, and turbulence distributions at two different clocking positions. In the planes upstream of the second vane, the time-resolved pressure field has been measured by means of a fast response aerodynamic pressure probe. This paper shows that the secondary flows of the second vane are significantly modified by the different clocking positions, in connection with the first vane modulation of the rotor secondary flows. An analysis of the performance of the second vane is also carried out, and a 0.6% variation in the second vane loss coefficient has been recorded among the different clocking positions.


2006 ◽  
Vol 129 (3) ◽  
pp. 580-590 ◽  
Author(s):  
P. Gaetani ◽  
G. Persico ◽  
V. Dossena ◽  
C. Osnaghi

An extensive experimental analysis was carried out at Politecnico di Milano on the subject of unsteady flow in high pressure (HP) turbine stages. In this paper, the unsteady flow measured downstream of a modern HP turbine stage is discussed. Traverses in two planes downstream of the rotor are considered, and, in one of them, the effects of two very different axial gaps are investigated: the maximum axial gap, equal to one stator axial chord, is chosen to “switch off” the rotor inlet unsteadiness, while the nominal gap, equal to 1/3 of the stator axial chord, is representative of actual engines. The experiments were performed by means of a fast-response pressure probe, allowing for two-dimensional phase-resolved flow measurements in a bandwidth of 80kHz. The main properties of the probe and the data processing are described. The core of the paper is the analysis of the unsteady rotor aerodynamics; for this purpose, instantaneous snapshots of the rotor flow in the relative frame are used. The rotor mean flow and its interaction with the stator wakes and vortices are also described. In the outer part of the channel, only the rotor cascade effects can be observed, with a dominant role played by the tip leakage flow and by the rotor tip passage vortex. In the hub region, where the secondary flows downstream of the stator are stronger, the persistence of stator vortices is slightly visible in the maximum stator-rotor axial gap configuration, whereas in the minimum stator-rotor axial gap configuration their interaction with the rotor vortices dominates the flow field. A good agreement with the wakes and vortices transport models has been achieved. A discussion of the interaction process is reported giving particular emphasis to the effects of the different cascade axial gaps. Some final considerations on the effects of the different axial gap over the stage performances are reported.


Author(s):  
O. Schennach ◽  
B. Paradiso ◽  
G. Persico ◽  
P. Gaetani ◽  
J. Woisetschla¨ger

The paper presents an experimental investigation of the flow field in a high-pressure transonic turbine with a downstream vane row (1.5 stage machine) concerning the airfoil indexing. The objective is a detailed analysis of the three dimensional flow field downstream of the high pressure turbine for different vane clocking positions. To give an overview of the time averaged flow field, measurements by means of a pneumatic five hole probe were performed upstream and downstream of the second stator. Furthermore in this planes additional unsteady measurements were carried out with Laser Doppler Velocimetry in order to record rotor phase resolved velocity, flow angle and turbulence distributions at two different clocking positions. In the measurement plane upstream the second vane the time resolved pressure field has been analyzed by means of a Fast Response Aerodynamic Pressure Probe. The paper shows that the secondary flows of the second vane are significantly modified for different clocking positions, in connection with the first vane modulation of the rotor secondary flows. An analysis of the performance of the second vane is also carried out.


Author(s):  
A. S. Witkowski ◽  
T. J. Chmielniak ◽  
M. D. Strozik

Detailed measurements have been performed in a low pressure axial flow compressor stage to investigate the structure of the secondary flow field and the three-dimensional wake decay at different axial locations before and behind the rotor. The three dimensional flow field upstream and downstream of the rotor and on the centerline of the stator blade passage have been sampled periodically using a straight and a 90 degree triple-split fiber probe. Radial measurements at 39 radial stations were carried out at chosen axial positions in order to get the span-wise characteristics of the unsteady flow. Taking the experimental values of the unsteady flow velocities and turbulence properties, the effects of the rotor blade wake decay and secondary flow on the blade row spacing and stator passage flow at different operating conditions are discussed. For the normal operating point, the component of radial turbulent intensities in the leakage-flow mixing region is found to be much higher than the corresponding axial and tangential components. But for a higher value of the flow coefficient the relations are different.The results of the experiments show that triple-split fiber probes, straight and 90 degree measurements, combined with the ensemble average technique are a very useful method for the analysis of rotor flow in turbomachinery. Tip clearance vortex, secondary flow near the hub and radial flow in the wake, turbulent intensity and Reynolds stresses and also the decay of the rotor wakes can be obtained by this method.


2019 ◽  
Vol 141 (4) ◽  
Author(s):  
Loris Simonassi ◽  
Manuel Zenz ◽  
Stefan Zerobin ◽  
Thorsten Selic ◽  
Franz Heitmeir ◽  
...  

Modern low pressure turbines (LPT) are designed in order to fulfil a various number of requirements such as high endurance, low noise, high efficiency, low weight, and low fuel consumption. Regarding the reduction of the emitted noise, different designs of LPT exit guide vanes (aerodynamically and/or acoustically optimized) of the turbine exit casing (TEC) were tested, and their noise reduction capabilities and aerodynamic performance were evaluated. In particular, measurements of TEC-losses were performed, and differences in the losses were reported. Measurements were carried out in a one and a half stage subsonic turbine test facility at the engine relevant operating point approach. This work focuses on the study of the unsteady flow field downstream of an unshrouded LPT rotor. The influence on the upstream flow field of a TEC design including acoustically optimized vanes (inverse cut-off TEC) is investigated and compared with a second TEC configuration without vanes (Vaneless TEC), by means of fast response aerodynamic pressure probe (FRAPP) measurements. The second configuration served as a reference concerning the influence of turbine exit guide vanes (TEGVs) onto the upstream located LPT rotor. The interactions between the stator and rotor wakes, secondary flows, and the TEGVs potential effect are identified via modal decomposition according to the theory of Tyler and Sofrin. The main structures constituting the unsteady flow field are detected, and the role of the major interaction effects in the loss generation mechanism and in the acoustic emission is analyzed. This study based on the modal analysis of the unsteady flow field offers new insight into the main interaction mechanisms and their importance in the assessment of the aerodynamic and aeroelastic performance of modern LPT exit casings.


Author(s):  
A. Perdichizzi ◽  
V. Dossena

This paper describes the results of an experimental investigation of the three-dimensional flow downstream of a linear turbine cascade at off-design conditions. The tests have been carried out for five incidence angles from −60 to +35 degrees, and for three pitch-chord ratios: s/c = 0.58,0.73,0.87. Data include blade pressure distributions, oil flow visualizations, and pressure probe measurements. The secondary flow field has been obtained by traversing a miniature five hole probe in a plane located at 50% of an axial chord downstream of the trailing edge. The distributions of local energy loss coefficients, together with vorticity and secondary velocity plots show in detail how much the secondary flow field is modified both by incidence and cascade solidity variations. The level of secondary vorticity and the intensity of the crossflow at the endwall have been found to be strictly related to the blade loading occurring in the blade entrance region. Heavy changes occur in the spanwise distributions of the pitch averaged loss and of the deviation angle, when incidence or pitch-chord ratio is varied.


Author(s):  
F. Didier ◽  
R. De´nos ◽  
T. Arts

This experimental investigation reports the convective heat transfer coefficient around the rotor of a transonic turbine stage. Both time-resolved and time-averaged aspects are addressed. The measurements are performed around the rotor blade at 15%, 50% and 85% span as well as on the rotor tip and the hub platform. Four operating conditions are tested covering two Reynolds numbers and three pressure ratios. The tests are performed in the compression tube turbine test rig CT3 of the von Karman Institute, allowing a correct simulation of the operating conditions encountered in modern aero-engines. The time-averaged Nusselt number distribution shows the strong dependence on both blade Mach number distribution and Reynolds number. The time-resolved heat transfer rate is mostly dictated by the vane trailing edge shock impingement on the rotor boundary layer. The shock passage corresponds to a sudden heat transfer increase. The effects are more pronounced in the leading edge region. The increase of the stage pressure ratio causes a stronger vane trailing edge shock and thus larger heat transfer fluctuations. The influence of the Reynolds number is hardly visible.


Sign in / Sign up

Export Citation Format

Share Document