pressure probe
Recently Published Documents


TOTAL DOCUMENTS

506
(FIVE YEARS 66)

H-INDEX

34
(FIVE YEARS 4)

Shock Waves ◽  
2022 ◽  
Author(s):  
M. Rezay Haghdoost ◽  
B. S. Thethy ◽  
M. Nadolski ◽  
B. Seo ◽  
C. O. Paschereit ◽  
...  

AbstractMitigation of pressure pulsations in the exhaust of a pulse detonation combustor is crucial for operation with a downstream turbine. For this purpose, a device termed the shock divider is designed and investigated. The intention of the divider is to split the leading shock wave into two weaker waves that propagate along separated ducts with different cross sections, allowing the shock waves to travel with different velocities along different paths. The separated shock waves redistribute the energy of the incident shock wave. The shock dynamics inside the divider are investigated using numerical simulations. A second-order dimensional split finite volume MUSCL-scheme is used to solve the compressible Euler equations. Furthermore, low-cost simulations are performed using geometrical shock dynamics to predict the shock wave propagation inside the divider. The numerical simulations are compared to high-speed schlieren images and time-resolved total pressure recording. For the latter, a high-frequency pressure probe is placed at the divider outlet, which is shown to resolve the transient total pressure during the shock passage. Moreover, the separation of the shock waves is investigated and found to grow as the divider duct width ratio increases. The numerical and experimental results allow for a better understanding of the dynamic evolution of the flow inside the divider and inform its capability to reduce the pressure pulsations at the exhaust of the pulse detonation combustor.


Author(s):  
Yang-chun Zhang ◽  
Shu-dao Zhou ◽  
Song Ye ◽  
Min Wang ◽  
Tao Yao

Abstract The conventional method of measuring a multi-hole probe is based on Bernoulli’s equation and suffers from certain model errors. A computational fluid dynamics (CFD)-based method was used in this study to reduce the theoretical error and establish a parametric model of the surface pressure of a spherical multi-hole pressure probe for measuring compressible flow fields at supersonic velocities. A flow field inversion method based on the parametric model is proposed herein. Numerical simulations were conducted to validate the proposed method. The experiment results show that in the compressible atmospheric flow field within Mach 1.2–1.7, the measurement errors of the inversion method were 1.3% and 2.35% for velocity and angle, respectively, thus verifying the feasibility of the method. Thus, a new method of measuring multi-hole pressure probe atmospheric flow fields was demonstrated.


2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
O Germanova ◽  
V A Germanov ◽  
Y V Shchukin ◽  
A V Germanov ◽  
G Galati

Abstract Purpose of study Using an original device for modeling of intra-arterial blood circulation, to study the features of intravascular hemodynamics with a regular heart rhythm and with various rhythm disturbances. Material and methods We used an original device developed by us to simulate intra-arterial circulation (Document of invention No. RU 202780 U1). The main part of the device is a glass tube of a rotameter with a length of 365 mm, an inlet end with a diameter of 20 mm, an outlet end of 16.5 mm, which is a model of an arterial vessel. Flexible silicone tubes are attached to the rotameter on both sides, with free ends connected to an electric pump, with various modes of operation (imitation of pulse waves with regular rhythm, premature ventricular contractions (PVCs), atrial fibrillation (AF). An aqueous solution of glycerin was introduced into a closed system diluted with water corresponding to the viscosity of the blood. A 5 mm long silk thread was alternately installed inside the tube, an intravascular piezoelectric crystal pressure probe connected to an oscilloscope. Also it was injected inside the tube a dye - clerical ink. Results With electric pump, we simulated the spreading of the pulse wave in regular heart rate, PVCs and AF. We observed the effect of a pressure wave (deflection of a silk thread, the appearance of a turbulent flow when using a dye) on the walls of the rotameter, with the formation of standing, reflected waves during the PVCs and AF. The pressure probe registered an increase in pressure inside the tube during the spread of the 1st post-extrasystolic contraction wave up to 58%, the wave after a long pause of more than 2 seconds with AF by 44% compared to the regular rhythm. Conclusion A device for modeling of intra-arterial circulation allows a wide range of experimental work in cardiology, normal and pathological physiology, and biophysics. FUNDunding Acknowledgement Type of funding sources: None.


Energies ◽  
2021 ◽  
Vol 14 (19) ◽  
pp. 6226
Author(s):  
Eva Koren ◽  
Miran Veselič ◽  
Goran Vižintin

In the area of the the Krško alluvial field, the Brežice hydroelectric power plant (BHPP), with its surface water reservoir, was completed in 2017. The new BHPP reservoir dam is located approximately 7 km air distance downstream of the old Krško nuclear power plant (NEK) reservoir dam. The NEK dam was built in the 1970s. The primary purpose of the NEK reservoir is to provide fresh water for cooling the NEK nuclear reactor. To assess the impact of the newly built surface water reservoir on groundwater, we performed a series of data analyses prior to its construction. One part of the analysis relating to data from the monitoring facility of the NEK showed an interesting correspondence between the water level oscillation in the NEK reservoir and the groundwater oscillation in the nearby observation well. Based on measurements taken in 2000, we sought to estimate the clogging of the Sava riverbed sediments in the area of the old NEK surface water reservoir. To determine the permeability of the riverbed sediments, we applied geometry similar to that chosen by Hantush for his pumping test method. Using Fourier analysis, we determined the dominant frequencies from the hydrograph records of the NEK surface water reservoir and from the pressure probe in the nearby observation well. Based on the determination of the dominant frequency, we used the wave equation to compare the influence of different values of the hydraulic transmissivity of the clogged part of the NEK surface water reservoir on the transfer of its water oscillations to the groundwater in the observation well. For the hydraulic values of the non-clogged part of the aquifer (T, S), we assumed the values from the pumping experiments performed in the alluvial aquifer of Krško polje. We also assumed that the aquifer is homogeneous and isotropic, as Hantush had assumed in his method for the determination of semipervious river beds. The results obtained indicated the potential for estimation of the thickness of the clogging layer which, by analogy from applied geophysics, can be called the apparent thickness. This meant that the thickness could be determined on the basis of the default conceptual model rather than on real measurements. The presented method shows the potential for using the analysis of periodic oscillations in river reservoir level and nearby piezometers, as a method of monitoring riverbed clogging, in cases where periodical oscillations in reservoir level occur and observation wells are near enough to detect the oscillations.


2021 ◽  
Vol 10 (19) ◽  
pp. 4335
Author(s):  
Daniel Schmitt ◽  
Sascha Halvachizadeh ◽  
Robin Steinemann ◽  
Kai Oliver Jensen ◽  
Till Berk ◽  
...  

There has been an ongoing discussion as to which interventions should be carried out by an “organ specialist” (for example, a thoracic or visceral surgeon) or by a trauma surgeon with appropriate general surgical training in polytrauma patients. However, there are only limited data about which exact emergency interventions are immediately carried out. This retrospective data analysis of one Level 1 trauma center includes adult polytrauma patients, as defined according to the Berlin definition. The primary outcome was the four most common emergency surgical interventions (ESI) performed during primary resuscitation. Out of 1116 patients, 751 (67.3%) patients (male gender, 530, 74.3%) met the inclusion criteria. The median age was 39 years (IQR: 25, 58) and the median injury severity score (ISS) was 38 (IQR: 29, 45). In total, 711 (94.7%) patients had at least one ESI. The four most common ESI were the insertion of a chest tube (48%), emergency laparotomy (26.3%), external fixation (23.5%), and the insertion of an intracranial pressure probe (ICP) (19.3%). The initial emergency treatment of polytrauma patients include a limited spectrum of potential life-saving interventions across distinct body regions. Polytrauma care would benefit from the 24/7 availability of a trauma team able to perform basic potentially life-saving surgical interventions, including chest tube insertion, emergency laparotomy, placing external fixators, and ICP insertion.


2021 ◽  
pp. 1-20
Author(s):  
Johannes Janssen ◽  
Daniel Pohl ◽  
Peter Jeschke ◽  
Alexander Halcoussis ◽  
Rainer Hain ◽  
...  

Abstract This paper presents the impact of an axially tilted variable stator vane platform on penny cavity flow and passage flow, with the aid of both optical and pneumatic measurements in an annular cascade wind tunnel as well as steady CFD analyses. Variable stator vanes in axial compressors require a clearance from the endwalls. This means that penny cavities around the vane platform are inevitable. Production and assembly deviations can result in a vane platform which is tilted about the circumferential axis.. Penny cavity and main flow in geometries with and without platform tilting were compared in an annular cascade wind tunnel. Detailed particle image velocimetry measurements were conducted inside the penny cavity and in the vane passage. Steady pressure and velocity data was obtained by two-dimensional multi-hole pressure probe traverses in the inflow and the outflow. Furthermore, pneumatic measurements were carried out using pressure taps inside the penny cavity. Additionally, oil flow visualization was conducted on the airfoil, hub, and penny cavity surfaces. Steady CFD simulations have been benchmarked against experimental data. The results show that tilting the vane platform reduces the penny cavity leakage mass flow. By decreasing penny cavity leakage, platform tilting also affects the passage flow where it leads to a reduced turbulence level and total pressure loss in the leakage flow region. In summary, the paper demonstrates the influence of penny platform tilting on cavity flow and passage flow and provides new insights into the mechanisms of penny cavity-associated losses.


2021 ◽  
Vol 11 (16) ◽  
pp. 7256
Author(s):  
Daryush D. Mehta ◽  
James B. Kobler ◽  
Steven M. Zeitels ◽  
Matías Zañartu ◽  
Emiro J. Ibarra ◽  
...  

The purpose of this paper is to report on the first in vivo application of a recently developed transoral, dual-sensor pressure probe that directly measures intraglottal, subglottal, and vocal fold collision pressures during phonation. Synchronous measurement of intraglottal and subglottal pressures was accomplished using two miniature pressure sensors mounted on the end of the probe and inserted transorally in a 78-year-old male who had previously undergone surgical removal of his right vocal fold for treatment of laryngeal cancer. The endoscopist used one hand to position the custom probe against the surgically medialized scar band that replaced the right vocal fold and used the other hand to position a transoral endoscope to record laryngeal high-speed videoendoscopy of the vibrating left vocal fold contacting the pressure probe. Visualization of the larynx during sustained phonation allowed the endoscopist to place the dual-sensor pressure probe such that the proximal sensor was positioned intraglottally and the distal sensor subglottally. The proximal pressure sensor was verified to be in the strike zone of vocal fold collision during phonation when the intraglottal pressure signal exhibited three characteristics: an impulsive peak at the start of the closed phase, a rounded peak during the open phase, and a minimum value around zero immediately preceding the impulsive peak of the subsequent phonatory cycle. Numerical voice production modeling was applied to validate model-based predictions of vocal fold collision pressure using kinematic vocal fold measures. The results successfully demonstrated feasibility of in vivo measurement of vocal fold collision pressure in an individual with a hemilaryngectomy, motivating ongoing data collection that is designed to aid in the development of vocal dose measures that incorporate vocal fold impact collision and stresses.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Hiroshi Wada ◽  
Keisuke Nakata ◽  
Hiroshi Nonami ◽  
Rosa Erra-Balsells ◽  
Miho Tatsuki ◽  
...  

AbstractWatercore is a physiological disorder in apple (Malus × domestica Borkh.) fruits that appears as water-soaked tissues adjacent to the vascular core, although there is little information on what exactly occurs at cell level in the watercored apples, particularly from the viewpoint of cell water relations. By combining picolitre pressure-probe electrospray-ionization mass spectrometry (picoPPESI-MS) with freezing point osmometry and vapor pressure osmometry, changes in cell water status and metabolisms were spatially assayed in the same fruit. In the watercored fruit, total soluble solid was lower in the watercore region than the normal outer parenchyma region, but there was no spatial difference in the osmotic potentials determined with freezing point osmometry. Importantly, a disagreement between the osmotic potentials determined with two methods has been observed in the watercore region, indicating the presence of significant volatile compounds in the cellular fluids collected. In the watercored fruit, cell turgor varied across flesh, and a steeper water potential gradient has been established from the normal outer parenchyma region to the watercore region, retaining the potential to transport water to the watercore region. Site-specific analysis using picoPPESI-MS revealed that together with a reduction in turgor, remarkable metabolic modifications through fermentation have occurred at the border, inducing greater production of watercore-related volatile compounds, such as alcohols and esters, compared with other regions. Because alcohols including ethanol have low reflection coefficients, it is very likely that these molecules would have rapidly penetrated membranes to accumulate in apoplast to fill. In addition to the water potential gradient detected here, this would physically contribute to the appearance with high tissue transparency and changes in colour differences. Therefore, it is concluded that these spatial changes in cell water relations are closely associated with watercore symptoms as well as with metabolic alterations.


2021 ◽  
Vol 254 ◽  
pp. 106942
Author(s):  
Gokhan Camoglu ◽  
Kursad Demirel ◽  
Fatih Kahriman ◽  
Arda Akcal ◽  
Hakan Nar ◽  
...  

Author(s):  
Guanghua Zheng ◽  
Fei Shui ◽  
Jinxin Hu ◽  
Xin Liu ◽  
Huazhong Xiao

In this paper, the measurement accuracy of two different types of total pressure probe and total temperature probe in turboshaft engine compressor inlet channel and the influence of these two probes on the flow field through numerical simulation was studied. At the same time, the influence of the probe structure and installation position on probe measurement results under three typical working conditions of cruise, maximum continuous and takeoff was analyzed. The simulation results showed that the higher the engine inlet flow rate, the greater the measurement error of the probe. Comparing with the total temperature probe, the total pressure probe measurement accuracy is more influenced by the flow rate. The velocity uniformity is less affected by the engine operating conditions and is mainly related to the structure of the inserted probes. The closer the total pressure probe to the support plate, the greater the measurement error. The probe installation position has a small effect on the total pressure loss coefficient at the outlet.


Sign in / Sign up

Export Citation Format

Share Document