Heat Transfer Characteristics of a Blade Trailing Edge With Pressure Side Bleed Extraction

Author(s):  
H. Saxer-Felici ◽  
S. Naik ◽  
M. Gritsch

This paper investigates the heat transfer and pressure loss characteristic in the internal cooling system of the trailing edge of a gas turbine blade. The geometrical profile of the blade trailing edge and the operating conditions considered are representative of that normally found in a heavy-duty gas turbine. The trailing edge geometry consists of two radial passages with inclined turbulators which are connected with a bend. The trailing edge section consists of pins rows and a flow ejection cut-out slot. The impact of a cross-over hole in the web connecting the serpentine passages is also investigated. Both numerical and experimental studies were conducted at several passage Reynolds numbers ranging from 104 to 106. Experiments were conducted in a Perspex model at atmospheric conditions. The internal heat transfer coefficients were measured via the transient liquid crystal method and the pressure drop was measured via pressure taps. The impact of blade rotation on the heat transfer and pressure drop was also assessed numerically. Comparison of the measured and predicted heat transfer coefficients and pressure drops shows a good agreement for several flow conditions. The three-dimensional flow field in the passage and in the downstream pin banks was well captured numerically, with and without coolant injection via cross-over hole.

Author(s):  
J. Kruekels ◽  
S. Naik ◽  
A. Lerch ◽  
A. Sedlov

The trailing edge sections of gas turbine vanes and blades are generally subjected to extremely high heat loads due to the combined effects of high external accelerating Mach numbers and gas temperatures. In order to maintain the metal temperatures of these trailing edges to a level, which fulfills the mechanical integrity of the parts, highly efficient cooling of the trailing edges is required without increasing the coolant consumption, as the latter has a detrimental effect on the overall gas turbine performance. In this paper the characteristics of the heat transfer and pressure drop of two novel integrated pin bank configurations were investigated. These include a pin bank with conical pins and a pin bank consisting of cylindrical pins and intersecting broken turbulators. As baseline case, a pin bank with cylindrical pins was studied as well. All investigations were done in a converging channel in order to be consistent with the real part. The heat transfer and pressure drop of all the pin banks were investigated initially with the use of numerical predictions and subsequently in a scaled experimental wind tunnel. The experimental study was conducted for a range of operational Reynolds numbers. The TLC (thermochromic liquid crystal) method was used to measure the detailed heat transfer coefficients in scaled Perspex models representing the various pin bank configurations. Pressure taps were located at several positions within the test sections. Both local and average heat transfer coefficients and pressure loss coefficients were determined. The measured and predicted results showed that the local internal heat transfer coefficient increases in the flow direction. This was due to the flow acceleration in the converging channel. Furthermore, both the broken ribs and the conical pin banks resulted in higher heat transfer coefficients compared with the baseline cylindrical pins. The conical pins produced the highest average internal heat transfer coefficients in contrast to the pins with the broken ribs, though this was also associated with a higher pressure drop.


Author(s):  
Carlo Carcasci ◽  
Bruno Facchini ◽  
Marco Pievaroli ◽  
Lorenzo Tarchi ◽  
Alberto Ceccherini ◽  
...  

In the present paper the combined effects of rotation and channel orientation on heat transfer and pressure drop along two scaled up matrix geometries suitable for trailing edge cooling of gas turbine airfoils are investigated. Experimental tests were carried out under static and rotating conditions. Rotating tests were performed for two different orientations of the matrix channel with respect to the rotating plane: 0deg and 30deg. This latter configuration is representative of the exit angle of a real gas turbine blade. Test models are designed in order to replicate an internal geometry suitable for blade trailing edge cooling, with a 90deg turning flow before entering the matrix array which has an axial development. Both the investigated geometries have a cross angle of 45deg between ribs and different values of sub-channels and rib thickness: one has four sub-channels and lower rib thickness (open area 84.5%), one has six sub-channels and higher rib thickness (open area 53.5%). Both geometries have a converging angle of 11.4deg. Matrix models have been axially divided in 5 aluminum elements per side in order to evaluate the heat transfer coefficient in 5 different locations in the main flow direction. Metal temperature was measured with embedded thermocouples and thin-foil heaters were used to provide a constant heat flux during each test. Heat transfer coefficients were measured applying a steady state technique based on a regional average method and varying the sub-channel Reynolds number Res from 2000 to 10000 and the sub-channel Rotation number Ros from 0 to 0.250 in order to have both Reynolds and Rotation number similitude with the real conditions. A post-processing procedure, which takes into account the temperature gradients within the model, was developed to correctly compute average heat transfer coefficients starting from discrete temperature measurements.


2021 ◽  
Author(s):  
Izzet Sahin ◽  
I-Lun Chen ◽  
Lesley M. Wright ◽  
Je-Chin Han ◽  
Hongzhou Xu ◽  
...  

Abstract A wide variety of pin-fins have been used to enhance heat transfer in internal cooling channels. However, due to their large blockage in the flow direction, they result in an undesirable high pressure drop. This experimental study aims to reduce pressure drop while increasing the heat transfer surface area by utilizing strip-fins in converging internal cooling channels. The channel is designed with a trapezoidal cross-section, converges in both transverse and longitudinal directions, and is also skewed β = 120° with respect to the direction of rotation in order to model a trailing edge cooling channel. Only the leading and trailing surfaces of the channel are instrumented, and each surface is divided into eighteen isolated copper plates to measure the regionally averaged heat transfer coefficient. Utilizing pressure taps at the inlet and outlet of the channel, the pressure drop is obtained. Three staggered arrays of strip-fins are investigated: one full height configuration and two partial fin height arrangements (Sz = 2mm and 1mm). In all cases, the strip fins are 2mm wide (W) and 10mm long (Lf) in the flow direction. The fins are spaced such that Sy/Lf = 1 in the streamwise direction. However, due to the convergence the spanwise spacing Sx/W, was varied from 8 to 6.2 along the channel. The rotation number of the channel varied up to 0.21 by ranging the inlet Reynolds number from 10,000 to 40,000 and rotation speed from 0 to 300rpm. It is found that the full height strip-fin channel results in a more non-uniform spanwise heat transfer distribution than the partial height strip-fin channel. Both trailing and leading surface heat transfer coefficients are enhanced under rotation conditions. The 2mm height partial strip-fin channel provided the best thermal performance, and it is comparable to the performance of the converging channels with partial length circular pins. The strip-fin channel can be a design option when the pressure drop penalty is a major concern.


2021 ◽  
Vol 143 (6) ◽  
Author(s):  
Izzet Sahin ◽  
I-Lun Chen ◽  
Lesley M. Wright ◽  
Je-Chin Han ◽  
Hongzhou Xu ◽  
...  

Abstract In the current study, the heat transfer and pressure drop characteristics of a rotating, partial pin-finned, cooling channel that has a trapezoidal cross section and converges from the hub to tip in both the streamwise and spanwise directions are experimentally investigated. To model the geometry of an internal trailing edge cooling passage, the channel is oriented with respect to the direction of rotation (β = 120 deg). Isolated copper plates are used to obtain regionally averaged heat transfer coefficients on the leading and trailing surfaces. Pressure drop is measured using pressure taps placed at the inlet and outlet of the channel. Utilizing Dp = 5 mm diameter pins, a staggered array is created. For this array, the streamwise pin-spacing, Sy/Dp = 2.1, was kept constant; however, the spanwise pin-spacing, Sx/Dp, was varied from the hub to tip between 3 and 2.6 due to the channel convergence. Experiments were conducted for two partial pin-fin sets having pin length-to-diameter ratios of Sz/Dp = 0.4 and 0.2. The rotation number was varied from 0 to 0.21 by ranging the inlet Reynolds number from 10,000 to 40,000 and rotation speed from 0 to 300 rpm. A significant decrease in pressure loss and a slight reduction in heat transfer enhancement are observed with the use of partial pin-fins compared with the previously reported full pin-fin converging channel study. This provides better thermal performances of the partial pin-fin arrays compared with the full pin-fin array, in the converging channels.


Author(s):  
K. S. Chana ◽  
K. J. Syed ◽  
M. I. Wedlock ◽  
R. W. Copplestone ◽  
M. S. Cook ◽  
...  

Lower NOx emissions from gas turbine combustion systems can be achieved through reducing the equivalence ratio of the main reaction zone and/or increasing the burner pressure drop. This strategy however takes pressure drop and/or air away from the combustor cooling, thereby compromising the combustor life. In order to achieve an optimum design that is a good compromise between low emissions and long component life, accurate heat transfer prediction is essential. It is well known that free stream turbulence can influence wall heat transfer characteristics. However the impact of combustion induced pressure dynamics, and the associated unsteady fluid dynamics, upon combustor wall heat transfer has not been adequately investigated. This paper reports on combustion tests conducted at gas turbine operating conditions, where pressure dynamics have been controlled by altering combustor operating conditions and through the use of a siren placed in the upstream air flow. Combustor wall temperatures were measured using standard thermocouples and QinetiQ’s “True Surface Thermocouples” (TST). The latter, which were mounted on the hot gas surface of the wall, are capable of a fast response and are capable of indicating the temperature fluctuations experienced by the metal surface. Fourier analysis of the TSTs showed no particular peaks associated with the pressure dynamics. This suggests that any coherence is damped within the boundary layer or by the thermal inertia of the metal. However temperature fluctuations of up to about 100°C were detected.


Author(s):  
Carlo Carcasci ◽  
Stefano Zecchi ◽  
Gianpaolo Oteri

CO2 emissions reduction has become an important topic, especially after Kyoto protocol. There are several ways to reduce the overall amount of CO2 discharged into the atmosphere, for example using alternative fluids such as steam or CO2. It is therefore interesting to analyze the consequences of their usage on overall performances of gas turbine and blade cooling systems. The presence of steam can be associated with combined or STIG cycle, whereas pure carbon dioxide or air-carbon dioxide mixtures are present in innovative cycles, where the exhaust gas is recirculated partially or even totally. In this paper we will analyze a commercial gas turbine, comparing different fluids used as working and cooling fluids. The different nature of the fluids involved determines different external heat transfer coefficients (external blade surface), different internal heat transfer coefficients (cooling cavities) and affects film cooling effectiveness, resulting in a change of the blade temperature distribution. Results show that the presence of steam and CO2 could determine a non negligible effect on blade temperature. This means that cooling systems need a deep investigation. A redesign of the cooling system could be required. In particular, results show that steam is well suited for internal cooling, whereas CO2 is better used in film cooling systems.


Author(s):  
Izzet Sahin ◽  
I-Lun Chen ◽  
Lesley M. Wright ◽  
Je-Chin Han ◽  
Hongzhou Xu ◽  
...  

Abstract The heat transfer and pressure drop characteristics of a rotating cooling channel that has an angled trapezoidal cross-section and converges from the hub to tip in both the streamwise and spanwise directions are experimentally investigated. The channel is oriented 120° with respect to the direction of rotation to model the geometry of an internal, trailing edge cooling passage. Both the leading and trailing sides of the channel are divided into three and six regions in the spanwise and streamwise directions, respectively. The copper plate method is used to obtain regionally averaged heat transfer coefficients. The pressure drop is measured utilizing pressure taps placed at the inlet and outlet of the channel. Experiments were conducted with the inlet Reynolds number ranging from 10,000 to 40,000. The rotational speed varies from 0 rpm to 300 rpm, resulting in the highest rotation number of 0.21. The effects of full pin-fins on the heat transfer and pressure drop characteristics are obtained and compared to the smooth surface converging channel results. The impact of the convergence, which causes variations of flow and geometric parameters through the passage, such as aspect ratio, Reynolds number, and rotation number, on the heat transfer coefficients and pressure drop are addressed. Results show that due to the 120° channel orientation, rotation has a positive impact on the leading and trailing surface heat transfer. Furthermore, the convergence decreases the aspect ratio while increasing Reynolds number. The convergence significantly enhances heat transfer on both the leading and trailing surfaces along the streamwise and spanwise directions. The convergence also reduces the rotation effect in the streamwise direction for a given mass flow rate.


2021 ◽  
Vol 143 (7) ◽  
Author(s):  
Izzet Sahin ◽  
I-Lun Chen ◽  
Lesley M. Wright ◽  
Je-Chin Han ◽  
Hongzhou Xu ◽  
...  

Abstract The heat transfer and pressure drop characteristics of a rotating cooling channel that has an angled trapezoidal cross section and converges from the hub to the tip in both the streamwise and spanwise directions are experimentally investigated. The channel is oriented 120 deg with respect to the direction of rotation to model the geometry of an internal, trailing-edge cooling passage. Both the leading and trailing sides of the channel are divided into three and six regions in the spanwise and streamwise directions, respectively. The copper plate method is used to obtain regionally averaged heat transfer coefficients. The pressure drop is measured using pressure taps placed at the inlet and outlet of the channel. Experiments were conducted with the inlet Reynolds number ranging from 10,000 to 40,000. The rotational speed varies from 0 rpm to 300 rpm, resulting in the highest rotation number of 0.21. The effects of full pin-fins on the heat transfer and pressure drop characteristics are obtained and compared to the smooth surface converging channel results. The impact of the convergence, which causes variations of flow and geometric parameters through the passage, such as aspect ratio, Reynolds number, and rotation number, on the heat transfer coefficients and pressure drop are addressed. Results show that due to the 120 deg channel orientation, the rotation has a positive impact on the leading and trailing surface heat transfer. Furthermore, the convergence decreases the aspect ratio while increasing the Reynolds number. The convergence significantly enhances heat transfer on both the leading and trailing surfaces along the streamwise and spanwise directions. The convergence also reduces the rotation effect in the streamwise direction for a given mass flow rate.


1979 ◽  
Author(s):  
D. K. Mukherjee

To design cooled gas turbine blades, heat transfer coefficients around its surface are required. The calculated heat transfer data under operating conditions in the turbine are often inaccurate and require experimental verification. A method is presented here to determine the heat transfer coefficients around the blade surface and in the coolant channels. This requires measurements of the main stream and coolant temperatures together with the outer surface temperature distribution at varying mass flows. In order to conduct these tests in a gas turbine, test blades have to be specially prepared allowing the variation and measurement of coolant mass flow.


Author(s):  
Bruno Facchini ◽  
Luca Innocenti ◽  
Lorenzo Tarchi

Short pin fins (pedestals) and long ribs (enlarged pedestals) are usually used in trailing edge cooling of turbine airfoils. To better reproduce the geometry of such cooling systems, test section of this experimental study is a wedge duct with inserts, to take into account effects of accelerating flow. A complete investigation of the system needs a separate evaluation of the heat transfer coefficients (HTC) for the pedestal surface and for the free endwall surface. In the present work an innovative technique made of different methods for these two different regions is presented, so cooling performances of each are evaluated. Thermochromic liquid crystal (TLC) transient technique is used to measure detailed heat transfer coefficients only on the endwall surface: a typical transparent (Plexiglas®) test article is used. Aluminum pedestals, employing a procedure based on a finite elements code, allow to measure the average heat transfer coefficient on the insert surface. To investigate the effects on transient technique of high conductive components, a comparison with Plexiglas inserts has been performed. Results show an underestimation of HTC with TLC transient technique only for aluminum long ribs at low Reynolds number values. Nevertheless the results seem to agree with other authors both for the endwall surface and for the entire cooling system.


Sign in / Sign up

Export Citation Format

Share Document