Design and Flow Analysis of a Rim-Driven Hub-Less Axial Flow Fan

2021 ◽  
Author(s):  
Hanqing Yang ◽  
Yijun Wang ◽  
Jinju Sun ◽  
Bangyi Wang ◽  
Youwei He ◽  
...  

Abstract Rim-driven hub-less fans have newly emerged as the most compact type of axial flow fans, which permits flexible configuration arrangements, large relative flow area and low-noise level operation. However, previous publications on rim-driven axial flow fans are rarely found in the open literature, and the flow mechanism and design principle of such promising fans haven’t yet been well-understood and established. This paper has been focused on a preliminary study of the rim-driven axial flow fan design and flow mechanism. A design method of the rim-driven fans is proposed on the basis of the isolated airfoil scheme and the variable circulation rule. It is further incorporated into a FORTRAN code and suited for designing the rim-driven hub-less fans of low-pressure levels. For validation purpose, a conventional hub-type fan is redesigned with the developed method and its flow behavior and overall performance are investigated numerically. A parametric study on the designed fan is further conducted respectively for the tangential velocity difference at mean span, circulation exponent and sweep angle and their influence on the fan flow characteristics and overall performance are explored and highlighted. On such a basis, the developed design method for the rim-driven axial flow fan is further improved. In comparison with the conventionally designed fan at identical rotating speed, significant comprehensive gains are arising from the redesigned fan of hub-less configuration: the overall pressure rise and static pressure efficiency is enhanced respectively by 6.2% and 11.5%, whereas the diameter of the fan is reduced by 12.5% simultaneously. It is demonstrated that the rim-driven hub-less configuration is promising for the enhancing the fan overall performance with even reduced dimensions.

Author(s):  
Thore Bastian Lindemann ◽  
Jens Friedrichs ◽  
Udo Stark

For a competitive low pressure axial fan design low noise emission is as important as high efficiency. In this paper a new design method for low pressure fans with a small hub to tip ratio including blade sweep is introduced and discussed based on experimental investigations. Basis is an empirical axial and tangential velocity distribution at the rotor outlet combined with a distinctive sweep angle distribution along the stacking line. Several fans were designed, built and tested in order to analyze the aerodynamic as well as the aeroacoustic behavior. For the aerodynamic performance particular attention was paid to compensate the influence of reduced pressure rise and efficiency due to increasing blade sweep. This was achieved by a method of increasing the blade chord depending on the local sweep angle which is based on single airfoil data. The tested fans without this compensation revealed a significant noise reduction effect of up to approx. 6 dB(A) for a tip sweep angle of 64° which was accompanied by an unsatisfactory effect of reduced overall aerodynamic performance. The second group of fans did not only confirm the method of the aerodynamic compensation by a nearly unchanged pressure rise and efficiency characteristic but also revealed an increased aeroacoustic benefit of in average 9.5 dB(A) compared to the unswept version. Beside the overall characteristics the individual differences between the designs are also discussed using results of wall pressure measurements which show some significant changes of the blade tip flow structure.


Author(s):  
Michael B. Wilkinson ◽  
Johan van der Spuy ◽  
Theodor W. von Backström

An axial flow fan design methodology is developed to design large diameter, low pressure rise, rotor-only fans for large air-cooled heat exchangers. The procedure aims to design highly efficient axial flow fans that perform well when subjected to off design conditions commonly encountered in air-cooled heat exchangers. The procedure makes use of several optimisation steps in order to achieve this. These steps include optimising the hub-tip ratio, vortex distribution, blading and aerofoil camber distributions in order to attain maximum total-to-static efficiency at the design point. In order to validate the design procedure a 24 ft, 8 bladed axial flow fan is designed to the specifications required for an air-cooled heat exchanger for a concentrated solar power (CSP) plant. The designed fan is numerically evaluated using both a modified version of the actuator disk model and a three dimensional periodic fan blade model. The results of these CFD simulations are used to evaluate the design procedure by comparing the fan performance characteristic data to the design specification and values calculated by the design code. The flow field directly down stream of the fan is also analysed in order to evaluate how closely the numerically predicted flow field matches the designed flow field, as well as determine whether the assumptions made in the design procedure are reasonable. The fan is found to meet the required pressure rise, however the fan total-to-static efficiency is found to be lower than estimated during the design process. The actuator disk model is found to under estimate the power consumption of the fan, however the actuator disk model does provide a reasonable estimate of the exit flow conditions as well as the total-to-static pressure characteristic of the fan.


2009 ◽  
Vol 131 (8) ◽  
Author(s):  
Alessandro Corsini ◽  
Franco Rispoli ◽  
A. G. Sheard

This study assesses the effectiveness of modified blade-tip configurations in achieving passive noise control in industrial fans. The concepts developed here, which are based on the addition of end-plates at the fan-blade tip, are shown to have a beneficial effect on the fan aeroacoustic signature as a result of the changes they induce in tip-leakage-flow behavior. The aerodynamic merits of the proposed blade-tip concepts are investigated by experimental and computational studies in a fully ducted configuration. The flow mechanisms in the blade-tip region are correlated with the specific end-plate design features, and their role in the creation of overall acoustic emissions is clarified. The tip-leakage flows of the fans are analyzed in terms of vortex structure, chordwise leakage flow, and loading distribution. Rotor losses are also investigated. The modifications to blade-tip geometry are found to have marked effects on the multiple vortex behaviors of leakage flow as a result of changes in the near-wall fluid flow paths on both blade surfaces. The improvements in rotor efficiency are assessed and correlated with the control of tip-leakage flows produced by the modified tip end-plates.


Author(s):  
Takahiro Nishioka ◽  
Shuuji Kuroda ◽  
Tadashi Kozu

An air-separator for extending the operating range of a variable-pitch axial-flow fan has been developed. It has a circular-are outer casing, a part of which forms the guide vane at the inlet of the air-separator. To obtain a wide operating range and to minimize penalties in terms of efficiency and noise, the influence of exposure and clearance ratios at various stagger-angle settings for rotor blades in low-speed and high-speed axial flow fans was experimentally investigated. Flow distributions and pressure fluctuations downstream of the rotor were also measured in order to investigate the influence of the air-separator on rotating stall. The distributions and fluctuations suggested that the air-separator decreased the blockage effect near the rotor tip and suppressed the rotating stall. Moreover, stall-margin and pressure-rise improvements were independent of the clearance ratio. These improvements depended on the exposure ratio and stagger-angle settings for the rotor blades. The fan efficiency for the air-separator also depended on the exposure ratio. In addition, the efficiency had the opposite tendency to the stall-margin and pressure-rise improvements. In contrast, the noise for the air-separator was independent of the exposure ratio and decreased as the clearance ratio increased. For the optimum combination of the exposure and clearance ratios, the stall-margin and pressure-rise were improved by over 20% with minimized penalties in terms of efficiency and noise. It is concluded from these results that the developed air-separator can provide a wide operating range for a variable-pitch axial-flow fan.


1999 ◽  
Vol 121 (1) ◽  
pp. 59-66 ◽  
Author(s):  
M. G. Beiler ◽  
T. H. Carolus

A numerical analysis of the flow in axial flow fans with skewed blades has been conducted to study the three-dimensional flow phenomena pertaining to this type of blade shape. The particular fans have a low pressure rise and are designed without stator. Initial studies focused on blades skewed in the circumferential direction, followed by investigations of blades swept in the direction of the blade chord. A Navier–Stokes code was used to investigate the flow. The simulation results of several fans were validated experimentally. The three-dimensional velocity field was measured in the fixed frame of reference with a triple sensor hot-film probe. Total pressure distribution measurements were performed with a fast response total pressure probe. The results were analyzed, leading to a design method for fans with swept blades. Forward swept fans designed accordingly exhibited good aerodynamic performance. The sound power level, measured on an acoustic fan test facility, improved.


Author(s):  
Michael B. Wilkinson ◽  
Sybrand J. van der Spuy ◽  
Theodor W. von Backström

An axial flow fan developed in the previous study is tested in order to characterize its performance. The M-fan, a 7.3152 m diameter rotor only axial flow fan was designed to perform well under the challenging operating conditions encountered in air-cooled heat exchangers. Preliminary computational fluid dynamics (CFD) results obtained using an actuator disk model (ADM) as well as a periodic three dimensional model indicate that the fan meets the specified performance targets, with an expected total-to-static efficiency of 59.4% and a total-to-static pressure rise of 114.7 Pa at the operating point. Experimental tests are performed on the M-fan in order to determine its performance across a full range of flow rates. A range of fan configurations are tested in order to ascertain the effect of tip clearance, blade angle, and hub configuration on fan performance. Due to the lack of a suitable facility for testing a large diameter fan, a scaled 1.542 m diameter model is tested on the ISO 5801 type A fan test facility at Stellenbosch University. A Reynolds-averaged Navier–Stokes CFD model representing the M-fan in the test facility is also developed in order to provide additional insight into the flow field in the vicinity of the fan blades. The results of the CFD model will be validated using the experimental data obtained. Both the CFD results and the experimental data obtained are compared to the initial CFD results for the full scale fan, as obtained in the previous study, by means of fan scaling laws. Experimental data indicate that the M-fan does not meet the pressure requirement set out in the initial study at the design blade setting angle of 34 deg. Under these conditions, the M-fan attains a total-to-static pressure rise of 102.5 Pa and a total-to-static efficiency of 56.4%, running with a tip gap of 2 mm. Increasing the blade angle is shown to be a potential remedy, improving the total-to-static pressure rise and efficiency obtained at the operating point. The M-fan is also shown to be highly sensitive to increasing tip gap, with larger tip gaps substantially reducing fan performance. The losses due to tip gap are also shown to be overestimated by the CFD simulations. Both experimental and numerically obtained results indicate lower fan total-to-static efficiencies than obtained in the initial CFD study. Results indicate that the M-fan is suited to its intended application, however, it should be operated with a smaller tip gap than initially recommended and a larger blade setting angle. Hub configuration is also shown to have an influence on fan performance, potentially improving performance at low flow rates.


Author(s):  
Andrew Gill ◽  
Theodor W. von Backström ◽  
Thomas M. Harms ◽  
Dwain Dunn

It has been shown in previous investigations that when all combinations of both positive and negative direction of rotation and flow direction are allowed in operating a multistage axial flow compressor, the operating point may be in any of the four quadrants of the pressure rise versus flow characteristic. The present paper is the first discussion of the flow field of all possible modes of operation of an axial flow compressor. During the present study interstage time dependent hot film velocity measurements and five hole pneumatic probe measurements were combined with steady and time dependent CFD solutions to investigate the flow fields in the three-stage axial compressor. Results are presented in terms of mean-line velocity triangles, mean stream surface plots, mid-span radial velocity contours right through the compressor, rotor-downstream radial distributions of axial and tangential velocity, stator-downstream axial velocity contours and mid-span entropy contours through the compressor. Main flow features are pointed out and discussed. The study was instigated in an effort to understand possible accident scenarios in a three-shaft closed cycle nuclear powered helium gas turbine.


Author(s):  
Takahiro Nishioka ◽  
Shuuji Kuroda ◽  
Tsukasa Nagano ◽  
Hiroshi Hayami

An experimental study was conducted to investigate the inception patterns of rotating stall at different rotor blade stagger-angle settings with the aim of extending the stable operating range for a variable-pitch axial-flow fan. Pressure and velocity fluctuations were measured for a low-speed axial-flow fan with a relatively large tip clearance. Two stagger-angle settings were tested, the design setting, and a high setting which was 10 degrees greater than the design setting. Rotating instability (RI) was first observed near the peak pressure-rise point at both settings. It propagated in the rotation direction at about 40 to 50% of the rotor rotation speed, and its wavelength was about one rotor-blade pitch. However, the stall-inception patterns differed between the two settings. At the design stagger-angle setting, leading edge separation occurred near the stall-inception point, and this separation induced a strong tip leakage vortex that moved upstream of the rotor. This leakage vortex simultaneously induced a spike and a RI. The conditions for stall inception were consistent with the simple model of the spike-type proposed by Camp and Day. At the high stagger-angle setting, leading edge separation did not occur, and the tip leakage vortex did not move upstream of the rotor. Therefore, a spike did not appear although RI developed at the maximum pressure-rise point. This RI induced a large end-wall blockage that extended into the entire blade passage downstream of the rotor. This large blockage rapidly increased the rotor blade loading and directly induced a long length-scale stall cell before a spike or modal disturbance appeared. The conditions for stall inception were not consistent with the simple models of the spike or modal-type. These findings indicate that the movement of the tip leakage vortex associated with the rotor blade loading affects the development of a spike and RI and that the inception pattern of a rotating stall depends on the stagger-angle setting of the rotor blades.


Sign in / Sign up

Export Citation Format

Share Document