Test and Evaluation of a Filtering System for Retention of Fibres in a Coolant Flow After Loss-of-Coolant Accident

Author(s):  
T. Gocht ◽  
W. Kästner ◽  
A. Kratzsch ◽  
M. Strasser

In case of an accident the safe heat removal from the reactor core with the installed emergency core cooling system (ECCS) is one of the main features in reactor safety. During a loss-of-coolant accident (LOCA) the release of insulation material fragments in the reactor containment can lead to malfunctions of ECCS. Therefore, the retention of particles by strainers or filtering systems in the ECCS is one of the major tasks. The aim of the presented experimental investigations was the evaluation of a filtering system for the retention of fiber-shaped particles in a fluid flow. The filtering system consists of a filter case with a special lamellar filter unit. The tests were carried out at a test facility with filtering units of different mesh sizes. Insulation material (mineral rock wool) was fragmented to fiber-shaped particles. To simulate the distribution of particle concentration at real plants with large volumes the material was divided into single portions and introduced into the loop with a defined time interval. Material was transported to the filter by the fluid and agglomerated there. The assessment of functionality of the filtering system was made by differential pressure between inlet and outlet of the filtering system and by mass of penetrated particles. It can be concluded that for the tested filtering system no penetration of insulation particles occurred.

2020 ◽  
Vol 01 (02) ◽  
pp. 53-60
Author(s):  
Pronob Deb Nath ◽  
Kazi Mostafijur Rahman ◽  
Md. Abdullah Al Bari

This paper evaluates the thermal hydraulic behavior of a pressurized water reactor (PWR) when subjected to the event of Loss of Coolant Accident (LOCA) in any channel surrounding the core. The accidental break in a nuclear reactor may occur to circulation pipe in the main coolant system in a form of small fracture or equivalent double-ended rupture of largest pipe connected to primary circuit line resulting potential threat to other systems, causing pressure difference between internal parts, unwanted core shut down, explosion and radioactivity release into environment. In this computational study, LOCA for generation III+ VVER-1200 reactor has been carried out for arbitrary break at cold leg section with and without Emergency Core Cooling System (ECCS). PCTRAN, a thermal hydraulic model-based software developed using real data and computational approach incorporating reactor physics and control system was employed in this study. The software enables to test the consequences related to reactor core operations by monitoring different operating variables in the system control bar. Two types of analysis were performed -500% area break at cold leg pipe due to small break LOCA caused by malfunction of the system with and without availability of ECCS. Thermal hydraulic parameters like, coolant dynamics, heat transfer, reactor pressure, critical heat flux, temperature distribution in different sections of reactor core have also been investigated in the simulation. The flow in the reactor cooling system, steam generators steam with feed-water flow, coolant steam flow through leak level of water in different section, power distribution in core and turbine were plotted to analyze their behavior during the operations. The simulation showed that, LOCA with unavailability of Emergency Core Cooling System (ECCS) resulted in core meltdown and release of radioactivity after a specific time.


Author(s):  
B. J. Yun ◽  
T. S. Kwon ◽  
D. J. Euh ◽  
I. C. Chu ◽  
C.-H. Song ◽  
...  

One of the advanced design features of the APR-1400, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLI) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood phase of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is in progress. In this paper, test results of a direct ECC bypass performed in the steam-water test facility called MIDAS (Multi-dimensional Investigation in Downcomer Annulus Simulation) is presented. The test condition is determined, based on the preliminary analysis of TRAC code, by applying the ‘modified linear scaling method’ with the 1/4.93 length scale. From the tests, ECC direct bypass fraction, steam condensation rate and information on the flow distribution in the upper annulus downcomer region is obtained.


Author(s):  
S. P. Saraswat ◽  
P. Munshi ◽  
A. Khanna ◽  
C. Allison

The initial design of ITER incorporated the use of carbon fiber composites in high heat flux regions and tungsten was used for low heat flux regions. The current design includes tungsten for both these regions. The present work includes thermal hydraulic modeling and analysis of ex-vessel loss of coolant accident (LOCA) for the divertor (DIV) cooling system. The purpose of this study is to show that the new concept of full tungsten divertor is able to withstand in the accident scenarios. The code used in this study is RELAP/SCADAPSIM/MOD 4.0. A parametric study is also carried out with different in-vessel break sizes and ex-vessel break locations. The analysis discusses a number of safety concerns that may result from the accident scenarios. These concerns include vacuum vessel (VV) pressurization, divertor temperature profile, passive decay heat removal capability of structure, and pressurization of tokamak cooling water system. The results show that the pressures and temperatures are kept below design limits prescribed by ITER organization.


2017 ◽  
Vol 19 (2) ◽  
pp. 59 ◽  
Author(s):  
Anhar Riza Antariksawan ◽  
Surip Widodo ◽  
Hendro Tjahjono

A postulated loss of coolant accident (LOCA) shall be analyzed to assure the safety of a research reactor. The analysis of such accident could be performed using best estimate thermal-hydraulic codes, such as RELAP5. This study focuses on analysis of LOCA in TRIGA-2000 due to pipe and beam tube break. The objective is to understand the effect of break size and the actuating time of the emergency core cooling system (ECCS) on the accident consequences and to assess the safety of the reactor. The analysis is performed using RELAP/SCDAPSIM codes. Three different break size and actuating time were studied. The results confirmed that the larger break size, the faster coolant blow down. But, the siphon break holes could prevent the core from risk of dry out due to siphoning effect in case of pipe break. In case of beam tube rupture, the ECCS is able to delay the fuel temperature increased where the late actuation of the ECCS could delay longer. It could be concluded that the safety of the reactor is kept during LOCA throughout the duration time studied. However, to assure the integrity of the fuel for the long term, the cooling system after ECCS last should be considered.  Keywords: safety analysis, LOCA, TRIGA, RELAP5 STUDI PARAMETRIK LOCA DI TRIGA-2000 MENGGUNAKAN RELAP5/SCDAP. Kecelakaan kehilangan air pendingin (LOCA) harus dianalisis untuk menjamin keselamatan suatu reaktor riset. Analisis LOCA dapat dilakukan menggunakan perhitungan best-estimate seperti RELAP5. Penelitian ini menekankan pada analisis LOCA di TRIGA-2000 akibat pecahnya pipa dan tabung berkas. Tujuan penelitian adalah memahami efek ukuran kebocoran dan waktu aktuasi sistem pendingin teras darurat (ECCS) pada sekuensi kejadian dan mengkaji keselamatan reaktor. Analisis dilakukan menggunakan program perhitungan RELAP/SCDAPSIM. Tiga ukuran kebocoran dan waktu aktuasi ECCS berbeda dipilih sebagai parameter dalam studi ini.  Hasil perhitungan mengonfirmasi bahwa semakin besar ukuran kebocoran, semakin cepat pengosongan tangki reaktor. Lubang siphon breaker dapat mencegah air terkuras dalam hal kebocoran pada pipa. Sedang dalam hal kebocoran pada beam tube, ECCS mampu memperlambat kenaikan temperatur bahan bakar. Dari studi ini dapat disimpulkan bahwa keselamatan reaktor dapat terjaga pada kejadian LOCA, namun pendinginan jangka panjang perlu dipertimbangkan untuk menjaga integritas bahan bakar.Kata kunci: analisis keselamatan, LOCA, TRIGA, RELAP5


Author(s):  
Stefan Renger ◽  
Sören Alt ◽  
Wolfgang Kästner ◽  
André Seeliger ◽  
Frank Zacharias

Background of experimental and methodical work is the loss of coolant accident (LOCA) with release of fibrous pipe insulation material. Latest investigations were focused on material deposition and distribution (cross mixing) in the reactor core. Therefore, a 2×2 PWR fuel assembly (FA) cluster was constructed. Four shortened PWR-FA-dummies are provided with separated in- and outlets. Every 16×16 fuel rod dummy consists of 20 control rod simulators, two spacers, FA-head and FA-bottom with a 3.5×3.5 mm integrated debris-screen filter (IDF). The cluster is encased in an acrylic housing for visual observation. It is connected with the test facility “Zittau Flow Tray” (ZFT), a simplified sump model, which allows inclusion and investigation of complex phenomena like material sedimentation in the sump and strainer blockages. A well mixing of air in the fluid was also considered by free jet expansions and flows through full cone-nozzles as well as marginal air entrainments. This Paper includes descriptions of applied measuring techniques (digital image processing, thrubeam laser sensors etc.) and an overview of all considered boundary conditions. Experimental results, aiming at the development, implementation and verification of multiphase flow and strainer models, are presented.


Author(s):  
Alan J. Bilanin ◽  
Andrew E. Kaufman ◽  
Warren J. Bilanin

Boiling Water Reactor pressure suppression pools have stringent housekeeping requirements, as well as restrictions on amounts and types of insulation and debris that can be present in the containment, to guarantee that suction strainers that allow cooling water to be supplied to the reactor during a Loss of Coolant Accident remain operational. By introducing “good debris” into the cooling water, many of these requirements/restrictions can be relaxed without sacrificing operational readiness of the cooling system.


Author(s):  
Cheng-Cheng Deng ◽  
Hua-Jian Chang ◽  
Ben-Ke Qin ◽  
Han Wang ◽  
Lian Chen

During small break loss of coolant accident (SBLOCA) of AP1000 nuclear plant, the behavior of pressurizer surge line has an important effect on the operation of ADS valves and the initial injection of IRWST, which may happen at a time when the reactor core reaches its minimum inventory. Therefore, scaling analysis of the PRZ surge line in nuclear plant integral test facilities is important. Four scaling criteria of surge line are developed, which respectively focus on two-phase flow pattern transitions, counter-current flow limitation (CCFL) behavior, periodic draining and filling and maintaining system inventory. The relationship between the four scaling criteria is discussed and comparative analysis of various scaling results is performed for different length scale ratios of test facilities. The results show that CCFL phenomenon and periodic draining and filling behavior are relatively more important processes and the surge line diameter ratios obtained by the two processes’ scaling criteria are close to each other. Thus, an optimal scaling analysis considering both CCFL phenomenon and periodic draining and filling process of PRZ surge line is given, which is used to provide a practical reference to choose appropriate scale of the surge line for the ACME (Advanced Core-cooling Mechanism Experiment) test facility now being built in China.


2017 ◽  
Vol 32 (1) ◽  
pp. 10-17
Author(s):  
Hyung-Wook Jang ◽  
Sang-Yong Lee ◽  
Seung-Jong Oh ◽  
Woong-Bae Kim

The phenomena of loss of coolant accident have been investigated for long time and the result of experiment shows that the flow condition in the downcomer during the end-of-blowdown were highly multi-dimensional at full-scale. However, the downcomer nodalization of input deck for large break loss of coolant accident used in advanced power reactor 1400 analyses are made up with 1-D model and improperly designed to describe realistic coolant phenomena during loss of coolant accident analysis. In this paper, the authors modified the nodalization of MARS code LBLOCA input deck and performed LBLOCA analysis with new input deck. From original LBLOCA input deck file, the nodalization of downcomer and junction connections with 4 cold legs and direct vessel injection lines are modified for reflecting the realistic cross-flow effect and real downcomer structure. The analysis results show that the peak cladding temperature of new input deck decreases more rapidly than previous result and that the drop of peak cladding temperature was advanced by application of momentum flux term in cross-flow. Additionally, the authors developed a new input deck with multi-dimensional downcomer model and ran MARS code with multi-dimensional input deck as well. By using the modified input deck, the Emergency core cooling system by-pass flow phenomena is better characterized and found to be consistent with both experimental report and regulatory guide.


Sign in / Sign up

Export Citation Format

Share Document