Effect of Film Cooling Holes Shape of Helium Turbine Blades in HTGR

Author(s):  
Xiaokai Sun ◽  
Wei Peng

The effect of holes shape on film cooling was investigated numerically in the present study. Three cases of holes which are sister holes located in the downstream (case 1), upstream (case 2) and side (case 3) were studied when keeping the flow area and flow rate constant. Cylindrical hole was also investigated to make a comparison. The results showed film cooling effectiveness is higher at the blowing ratio M = 0.5 for cylindrical hole; while for the hole with sister holes, film cooling performance is better at corresponding blowing ratio M = 1.0 and it is better than that of the cylindrical hole. The reason is that the interaction between the mainstream and the cooling stream produces the counter-rotating vortex pairs (CVP) at high blowing ratio, which will make the hot mainstream underneath the cooling stream and lifts the cooling stream from the surface for the cylindrical hole. And the three cases of holes with sister holes can weaken the effect of the CVP.

Author(s):  
JeongJu Kim ◽  
Wonjik Seo ◽  
Minho Bang ◽  
Seon Ho Kim ◽  
Seok Min Choi ◽  
...  

Film cooling effectiveness and heat transfer were measured in squealer tip configurations on the blade tip surface. Three different shelf squealer tip geometries were studied: conventional, vertical, and inclined. The experiment was carried out in a wind tunnel with an inlet mainstream Reynolds number, based on the axial chord length of the blade, of 140,000. The experiments were conducted in five blades in linear cascade with an averaged turbulence intensity of 8.5%. The film cooling effectiveness and heat transfer coefficient on the tip surface were obtained using the transient IR thermography technique. For the pressure side film cooling holes, averaging blowing ratios (M) of 1.0 and 2.0 were set. The results showed the film cooling effectiveness distributions on the tip surface. Owing to the mainstream, the cooling effect appeared after x/Cx = 0.15 and the film cooling effectiveness tended to increase toward downstream of the trailing edge. Additionally, the heat transfer distributions were investigated regarding the film cooling holes. In the presence of film cooling holes, the heat transfer distribution had more uniformity than without them on the pressure side. As the blowing ratio increased from 1 to 2, the heat transfer was decreased on the tip surface. The heat transfer ratio represented the change of heat transfer distribution with and without film cooling holes. Those of results were compared in three squealer tip geometries. The overall area-averaged net heat flux reduction (NHFR) levels on the tip surface were enhanced as the blowing ratio increased. The NHFR of the shelf squealer tip configurations was better than that with the conventional squealer tip.


2021 ◽  
Author(s):  
Izhar Ullah ◽  
Sulaiman M. Alsaleem ◽  
Lesley M. Wright ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han

Abstract This work is an experimental study of film cooling effectiveness on a blade tip in a stationary, linear cascade. The cascade is mounted in a blowdown facility with controlled inlet and exit Mach numbers of 0.29 and 0.75, respectively. The free stream turbulence intensity is measured to be 13.5 % upstream of the blade’s leading edge. A flat tip design is studied, having a tip gap of 1.6%. The blade tip is designed to have 15 shaped film cooling holes along the near-tip pressure side (PS) surface. Fifteen vertical film cooling holes are placed on the tip near the pressure side. The cooling holes are divided into a 2-zone plenum to locally maintain the desired blowing ratios based on the external pressure field. Two coolant injection scenarios are considered by injecting coolant through the tip holes only and both tip and PS surface holes together. The blowing ratio (M) and density ratio (DR) effects are studied by testing at blowing ratios of 0.5, 1.0, and 1.5 and three density ratios of 1.0, 1.5, and 2.0. Three different foreign gases are used to create density ratio effect. Over-tip flow leakage is also studied by measuring the static pressure distributions on the blade tip using the pressure sensitive paint (PSP) measurement technique. In addition, detailed film cooling effectiveness is acquired to quantify the parametric effect of blowing ratio and density ratio on a plane tip design. Increasing the blowing ratio and density ratio resulted in increased film cooling effectiveness at all injection scenarios. Injecting coolant on the PS and the tip surface also resulted in reduced leakage over the tip. The conclusions from this study will provide the gas turbine designer with additional insight on controlling different parameters and strategically placing the holes during the design process.


2012 ◽  
Vol 225 ◽  
pp. 49-54 ◽  
Author(s):  
Kamil Abdullah ◽  
Ken Ichi Funazaki

This paper presents the investigation on the effects of the blowing ratio of multiple shallow angle film cooling holes. Multiple film cooling holes having a shallow hole angle (θ = 20°), arranged to perform in-line hole configuration has been considered in the present study. The investigation focuses on the effects of high blowing ratio of the film cooling effectiveness which have been carried out at ReD= 3100 and BR = 2.0, 3.0 and 4.0. The experiments make use of the IR camera in capturing the surface temperature to determine the film cooling effectiveness. The contours of the film cooling effectiveness distribution together with plots on laterally average film cooling effectiveness along the x/D are presented. The discussions have been made with a support of the temperature field captured at x/D = 3, 13, 23, and 33. The results clearly show the benefit of the employment of shallow hole angle (θ = 20°) at high blowing ratio which is much more superior in comparison to the common hole configuration (θ = 35°).


2005 ◽  
Vol 127 (5) ◽  
pp. 521-530 ◽  
Author(s):  
Jaeyong Ahn ◽  
Shantanu Mhetras ◽  
Je-Chin Han

Effects of the presence of squealer, the locations of the film-cooling holes, and the tip-gap clearance on the film-cooling effectiveness were studied and compared to those for a plane (flat) tip. The film-cooling effectiveness distributions were measured on the blade tip using the pressure-sensitive paint technique. Air and nitrogen gas were used as the film-cooling gases, and the oxygen concentration distribution for each case was measured. The film-cooling effectiveness information was obtained from the difference of the oxygen concentration between air and nitrogen gas cases by applying the mass transfer analogy. Plane tip and squealer tip blades were used while the film-cooling holes were located (a) along the camber line on the tip or (b) along the tip of the pressure side. The average blowing ratio of the cooling gas was 0.5, 1.0, and 2.0. Tests were conducted with a stationary, five-bladed linear cascade in a blow-down facility. The free-stream Reynolds number, based on the axial chord length and the exit velocity, was 1,138,000, and the inlet and the exit Mach numbers were 0.25 and 0.6, respectively. Turbulence intensity level at the cascade inlet was 9.7%. All measurements were made at three different tip-gap clearances of 1%, 1.5%, and 2.5% of blade span. Results show that the locations of the film-cooling holes and the presence of squealer have significant effects on surface static pressure and film-cooling effectiveness, with film-cooling effectiveness increasing with increasing blowing ratio.


Author(s):  
Rui Zhu ◽  
Gongnan Xie ◽  
Terrence W. Simon

In search of improved cooling of gas turbine blades, the thermal performances of two different film cooling hole geometries (horn-shaped and cylindrical) are investigated in this numerical study. The horn-shaped hole is designed from a cylindrical hole by expanding the hole in the transverse direction to double the hole size at the exit. The two hole shapes are evaluated singly and in tandem. The tandem geometry assumes three configurations made by locating the cylindrical hole at three different positions relative to the horn-shaped hole such that their two axes remain parallel to one another. One has the cylindrical hole downstream from the center of the horn-shaped hole, a second has the cylindrical hole to the left of (as seen by the flow emerging from the horn-shaped hole) and at the same streamwise location as the horn-shaped hole (θ = 90°) and the third has an intermediate geometry between those two geometries (downstream and to the left of the horn-shaped hole - θ = 45°). It is shown from the simulation results that the cooling effectiveness values for the θ = 45° and 90° cases are much better than that for θ = 0° (the first case), and the configuration with θ = 45° exhibits the best cooling performance of the three tandem arrangements. These improvements are attributed to the interaction of vortices from the two different holes, which weakens the counter-rotating vortex pairs inherent to film cooling jet to freestream interaction, counteracts with the lift forces, enhances transverse tensile forces and, thus, enlarges the film coverage zone by widening the flow attachment region. Overall, this research reveals that integration of horn-shaped and cylindrical holes provides much better film cooling effectiveness than cases where two cylindrical film cooling holes are applied with the same tandem configuration.


Author(s):  
Jin Wang ◽  
Bengt Sundén ◽  
Min Zeng ◽  
Qiu-Wang Wang

Three-dimensional simulations of the squealer tip on the GE-E3 blade with eight film cooling holes were carried out. To form the wake by the trailing edges of the stator vanes, cylindrical rods and delta wings were placed upstream of the blades. The rods were placed according to three positions, and the influence on the film cooling effectiveness was calculated. Because delta wings were placed upstream of the blades to generate in the vane passage, the passage flow also was investigated. However, the passage vortex generated by the delta wings had a profound effect on the passage flow distribution. For the squealer tip, the cavity contributes to the improvement of the cooling effect in the tip zone. The passage flow and the tip leakage flow influenced by cylindrical rods and delta wings were analyzed using numerical simulations with the blowing ratio of M = 0.5. In addition, calculations with and without cylindrical rods and delta wings were performed and then comparisons were enabled. It was found that the vortex created by delta wings made the passage flow more turbulent and the result indicates a slight effect on the film cooling effectiveness in the tip gap.


Author(s):  
Chao Zhang ◽  
Jie Wang ◽  
Xin Luo ◽  
Liming Song ◽  
Jun Li ◽  
...  

Abstract In our experiments, the film cooling performance of the configurations combined the different hole with the vortex generator was investigated experimentally, measured by the infrared camera. Four different configurations were studied at the blowing ratio varying at M = 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0. In all cases, the Reynold number of the mainstream based on the hole diameter remained at Re = 8000, and the density ratio kept at DR = 1.7. Experimental results show that for the two models combining the cylindrical hole and fan-shaped hole with the vortex generator respectively, the film cooling performance becomes better when the blowing ratio increases from M = 0.5 to M = 2.0, and then decreases when the blowing ratio increases from M = 2.0 to M = 3.0. The model combining the fan-shaped hole with the vortex generator performs the best among the four models at each blowing ratio. Its film attachment holds the most extensive lateral distribution and its overall film cooling effectiveness could keep at a high level at a wide range of blowing ratios from M = 1.0 to M = 3.0. The combined model of the fan-shaped hole could improve the area-averaged film effectiveness at most 25.5% than that of the single hole model at M = 2.0. Moreover, the combined model of the cylindrical hole could improve the area-averaged film cooling effectiveness at most 431% than that of the single cylindrical hole model at M = 3.0.


Author(s):  
Shubham Agarwal ◽  
Laurent Gicquel ◽  
Florent Duchaine ◽  
Nicolas Odier ◽  
Jérôme Dombard

Abstract Understanding the flow from a cooling hole is very important to be able to properly control film cooling of turbine blades. For this purpose, large eddy simulation (LES) investigation of the flow inside a cylindrical film cooling hole is presented in this paper. Two different geometries, with different hole metering lengths, are investigated at a blowing ratio of 0.5. The main flow structure in the hole are the hairpin vortices that originate from a shear layer formed due to flow separation near the hole entry. The comparison of these hairpin vortices in the two cases with different hole metering length is presented in detail. The results show that in case of the hole with longer length the hairpin vortices dissociate within the hole itself. In such a case a uniform flow is seen at the hole exit. However, when the hole length is significantly decreased, it is shown that these vortices exit the hole and effect the vortex structures outside the hole, thereby accounting for the reduction in film cooling effectiveness. Overall, these results bring forth one other major reason for the reduction in film cooling effectiveness with reduction in hole length, i.e. the exit of in-hole hairpin vortices into the crossflow.


2018 ◽  
Vol 140 (12) ◽  
Author(s):  
Jiaxu Yao ◽  
Jin Xu ◽  
Ke Zhang ◽  
Jiang Lei ◽  
Lesley M. Wright

The interaction of flow and film-cooling effectiveness between jets of double-jet film-cooling (DJFC) holes on a flat plate is studied experimentally. The time-averaged flow field in several axial positions (X/d = −2.0, 1.0, and 5.0) is obtained through a seven-hole probe. The downstream film-cooling effectiveness on the flat plate is measured by pressure sensitive paint (PSP). The inclination angle (θ) of all the holes is 35 deg, and the compound angle (β) is ±45 deg. Effects of the spanwise distance (p = 0, 0.5d, 1.0d, 1.5d, and 2.0d) between the two interacting jets of DJFC holes are studied, while the streamwise distance (s) is kept as 3d. The blowing ratio (M) varies as 0.5, 1.0, 1.5, and 2.0. The density ratio (DR) is maintained at 1.0. Results show that the interaction between the two jets of DJFC holes has different effects at different spanwise distances. For a small spanwise distance (p/d = 0), the interaction between the jets presents a pressing effect. The downstream jet is pressed down and kept attached to the surface by the upstream one. The effectiveness is not sensitive to blowing ratios. For mid-spanwise distances (p/d = 0.5 and 1.0), the antikidney vortex pair dominates the interaction and pushes both of the jets down, thus leading to better coolant coverage and higher effectiveness. As the spanwise distance becomes larger (p/d ≥ 1.5), the pressing effect almost disappears, and the antikidney vortex pair effect is weaker. The jets separate from each other and the coolant coverage decreases. At a higher blowing ratio, the interaction between the jets of DJFC holes happens later.


Author(s):  
Yingjie Zheng ◽  
Ibrahim Hassan

This paper presents experimental flow field investigations of a film cooling scheme, referred to as nozzle scheme, on a flat plate using stereo PIV. The nozzle scheme has a cylindrical hole and internal obstacles to change the velocity distribution near the hole exit and hence the jet-mainstream interaction. Counter-rotating vortex pair (CRVP) is known to be one of the detrimental effects that affect the film cooling effectiveness. Previous CFD simulations demonstrated nozzle hole’s capability of reducing CRVP strength and enhancing film cooling effectiveness in comparison with a normal cylindrical hole. The present study examines the nozzle hole flow filed experimentally at blowing ratio ranged from 0.5 to 2.0 and compares with cylindrical hole. The experiments were conducted in a low-speed wind tunnel with a mainstream Reynolds number of 115,000 and the density ratio was 1.0 during all the investigations. The experimental results show that nozzle hole reduces streamwise vorticity of CRVP by an average of 55% at low blowing ratio, and 34%–40% at high blowing ratios. The velocity field and vorticity field of nozzle jet are compared with cylindrical jet. The result reveals that the nozzle jet forms a round bulk in contrast to the kidney shape jet core in cylindrical hole case. In addition, it is found that CRVP strength may not be a primary contributor to the jet lift-off.