A Microfabricated Chip for the Study of Cell Electroporation

2000 ◽  
Author(s):  
Yong Huang ◽  
Boris Rubinsky

Abstract It has been observed that when certain electrical potentials are applied across a cell they can induce the formation of pores in the cell membrane and consequently increase the permeability of the cell to macromolecules. This phenomenon is known as electroporation. Since the first report on gene transfer by electroporation1, it has become a standard method for introduction of macromolecules into cells2 3 4. Currently, electroporation is normally done in batches of cells between electrodes and there is little control over the permeabilization of individual cells. Therefore, it is very difficult to study the fundamental biophysics of cell membrane electro-permeabilization and to design optimal electroporation protocols for individual cells2 3 . Although the biophysics of electroporation are still not fully understood, indirect evidence shows that micro aqueous pores with diameters of tens to hundreds of angstroms are created in the cell membrane due to the electrical field induced structural rearrangement of the lipid bilayer5. It occurred to us that if electroporation induces pores in the cell membrane, then in a state of electroporation, a measurable current should flow through the individual cell. From this idea, we have developed a new micro-electroporation technology that employs a “bionic” chip to study and control the electroporation process in individual cells. The micro-electroporation chip, shown schematically in Figure 1, is designed and fabricated using standard silicon microfabrication technology. Each chip is a three-layer device that consists of two translucent poly silicon electrodes and a silicon nitride membrane, which all together form two fluid chambers. The two chambers are interconnected only through a micro hole through the dielectric silicon nitride membrane. In a typical process, the two chambers are filled with conductive solutions and one chamber contains biological cells. Individual cells can be captured in the micro hole and thus incorporated into the electrical circuit between the two electrodes of the chip. When the cell is in its normal state no current flows through the insulating lipid bilayer and consequently between the electrodes. However, when the electrical potential across the electrodes is sufficient to induce electroporation, a measurable current will flow through the pores of the cell membrane and between the electrodes. Measuring the currents through the bionic chip in real time will reveal the information of the state of electropermeabilization in cell membrane. The breakdown potential of irreversible electroporation, the most critical parameter in electroporation process, can be detected by analyzing current signals as well. Figure 2 illustrates a typical electrical signature in an irreversible electroporation process. Once the target cell is electroporated by the application of sufficient electroporation electrical potentials, macromolecules that are normally impermeant to cell membrane can be uploaded into the cell. Figure 3 shows how a cell entrapped in a hole is loaded during electroporation with a fluorescent die. With the ability to manipulate individual cells and detect the electrical potentials that induce electroporation in each cell, the chip can be used to study the fundamental biophysics of membrane electropermeabilization on the single cell level and in biotechnology, for controlled introduction of macromolecules, such as DNA fragments, into individual cells. We anticipate that this new technology will change the way in which electroporation is done and will provide key understanding of the biophysical processes that lead to cell electroporation. This paper will discuss the design, fabrication of the micro-electroporation chip, the experiment system as well as experiments carried out to precisely detect the parameters of electroporation of individual biological cells.

2000 ◽  
Author(s):  
Yong Huang ◽  
Boris Rubinsky

Abstract It has been observed that when certain electrical potentials are applied across a cell they can induce the formation of pores in the cell membrane and consequently increase the permeability of the cell to macromolecules. This phenomenon is known as electroporation. Since the first report on gene transfer by electroporation1, it has become a standard method for introduction of macromolecules into cells2 3 4. Currently, electroporation is normally done in batches of cells between electrodes and there is little control over the permeabilization of individual cells. Therefore, it is very difficult to study the fundamental biophysics of cell membrane electro-permeabilization, which is not yet understood, and to design optimal and reversible electroporation protocols for individual cells2 3. Although the biophysics of electroporation are still not fully understood, indirect evidence shows that micro aqueous pores with diameters of tens to hundreds of angstroms are created in cell membrane due to the electrical field induced structural rearrangement of the lipid bilayer5. It occurred to us that if electroporation induces pores in the cell membrane than, in a state of electroporation, a measurable current should flow through the individual cell. From this idea, we have developed a new micro-electroporation technology that employs a “bionic” chip to study and control the electroporation process in individual cells. The micro-electroporation chips are designed and fabricated using standard silicon microfabrication technology. Figure 1 shows the schematic of the chip in cross section. Each chip is a three-layer device that consists of two translucent poly silicon electrodes and a silicon nitride membrane, which all together form two fluid chambers. The two chambers are interconnected only through a micro hole on the dielectric silicon nitride membrane. In a typical process, the two chambers are filled with conductive solutions and one chamber contains biological cells. Individual cells can be captured in the micro hole and thus incorporated in the electrical circuit between the two electrodes of the chip. When the cell is in its normal state no current flows through the insulating lipid bilayer and consequently between the electrodes. However, when the electrical potential across the electrodes is sufficient to induce electroporation, a measurable current will flow through the pores of the cell membrane and between the electrodes. Measuring currents through the bionic chip as a function of electrical potential will determine the potential that induces the electroporation. The chip behaves somewhat similarly to an electrical diode, with no current at potentials that do not induce electroporation and currents at potentials that induce electroporation. With the ability to manipulate individual cells and detect the electrical potentials that induce electroporation in each cell, the chip can be used to study the fundamental biophysics of membrane electro-permeabilization on single cell level and in biotechnology, for controlled introduction of macromolecules, such as gene constructs, into individual cells. We anticipate that this new technology will change the way in which electroporation is done and will provide key understanding of the biophysical processes that lead to cell electroporation. In this paper, first the design, fabrication process and modeling of the microelectroporation chip are described in details. Subsequently, experiment methods and results are presented and discussed, demonstrating the feasibility of altering cell membrane permeability and facilitating intercellular mass transfer in a more controlled way on single cell level. Finally, the potential applications of the micro-electroporation chips and future research directions are discussed. Figure 2 demonstrates how cell membrane electroporation can be investigated through monitoring and analyzing chip current-voltage signatures.


Author(s):  
Robert E. Neal ◽  
Ravi Singh ◽  
Suzy Torti ◽  
Rafael V. Davalos

Non-thermal irreversible electroporation (IRE) is a new, minimally invasive, localized tissue ablation technique [1]. The procedure uses electrodes to deliver short-length, high voltage electric pulses to destabilize a cell membrane, leading to the creation of nanopores. When the pulses are strong enough, the cell cannot repair the damage and dies [2]. It has been shown that substantial volumes of tissue and cutaneous tumors may be ablated in a non-thermal manner using irreversible electroporation [1, 3]. In addition, this procedure may be predicted by numerical modeling, promotes an immune response, leaves the extracellular matrix intact, does not affect nerves, may be monitored in real-time, and preserves tissue vasculature [2–5].


1978 ◽  
Vol 235 (5) ◽  
pp. F507-F514
Author(s):  
L. Reuss ◽  
J. T. Gatzy ◽  
A. L. Finn

The mechanisms of action of amphotericin B on the electrical properties of the toad urinary bladder epithelium were studied with microelectrode techniques. Cell membrane and transepithelial electrical potentials and resistances were measured in the absence and in the presence of the drug during exposure to bathing mediums of different ionic compositions. As observed previously by other investigators, amphotericin B produces a dramatic decrease of transepithelial electrical resistance (Rt) and an increase of the rate of sodium transport. Our results indicate that the effect of the drug on Rt depends in part on an increase in Na conductance across the luminal cell membrane (amiloride-insensitive), but is caused mainly by an increase of ionic conductances (with the sequence GK greater than GNa greater than G choline greater than GCI) at a site in parallel with the impaled cells (i.e., across a cell type not investigated by the microelectrode measurements or across the paracellular pathway.


2007 ◽  
Vol 6 (4) ◽  
pp. 255-259 ◽  
Author(s):  
Boris Rubinsky

This is a brief introduction to the emerging field of irreversible electroporation in medicine. Certain electrical fields when applied across a cell can have as a sole effect the permeabilization of the cell membrane, presumable through the formation of nanoscale defects in the cell membrane. Sometimes this process leads to cell death, primarily when the electrical fields cause permanent permeabilization of the membrane and the consequent loss of cell homeostasis, in a process known as irreversible electroporation. This is an unusual mode of cell death that is not understood yet. While the phenomenon of irreversible electroporation may have been known for centuries it has become only recently rigorously considered in medicine for various applications of tissue ablation. A brief historical perspective of irreversible electroporation is presented and recent studies in the field are discussed.


Author(s):  
Rohit Rastogi ◽  
Mamta Saxena ◽  
Devendra K Chaturvedi ◽  
Mayank Gupta ◽  
Neha Gupta ◽  
...  

Bioelectricity occurs inside a living organism. It is nature through which living beings survive. It is a phenomenon through which organisms live and is also parallel to electrophysiology. Bioelectric potentials are generated by many biological processes. Bioelectric potentials are very like electrical potentials, which are generated by batteries. The bioelectric potential in a cell membrane has a potential of about 500 milli volts. Cells use their potential to control metabolic processes. But some cells use them differently for psychological functions. Cells allow the potential to be between inside and outside to discharge current to the nerves. The transportation of sodium ions is also involved in production of action potential, the ancient Indian vedic yajna, mantra, and meditation science has been proved effective to increase this bioelectricity. In this manuscript, the authors examined the different energy distribution of subjects on different organs.


2002 ◽  
Vol 722 ◽  
Author(s):  
T. S. Sriram ◽  
B. Strauss ◽  
S. Pappas ◽  
A. Baliga ◽  
A. Jean ◽  
...  

AbstractThis paper describes the results of extensive performance and reliability characterization of a silicon-based surface micro-machined tunable optical filter. The device comprises a high-finesse Fabry-Perot etalon with one flat and one curved dielectric mirror. The curved mirror is mounted on an electrostatically actuated silicon nitride membrane tethered to the substrate using silicon nitride posts. A voltage applied to the membrane allows the device to be tuned by adjusting the length of the cavity. The device is coupled optically to an input and an output single mode fiber inside a hermetic package. Extensive performance characterization (over operating temperature range) was performed on the packaged device. Parameters characterized included tuning characteristics, insertion loss, filter line-width and side mode suppression ratio. Reliability testing was performed by subjecting the MEMS structure to a very large number of actuations at an elevated temperature both inside the package and on a test board. The MEMS structure was found to be extremely robust, running trillions of actuations without failures. Package level reliability testing conforming to Telcordia standards indicated that key device parameters including insertion loss, filter line-width and tuning characteristics did not change measurably over the duration of the test.


Physics Today ◽  
2010 ◽  
Vol 63 (9) ◽  
pp. 17-17
Author(s):  
Mark Wilson
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document