Reduced Order Model of MEMS Sensors Near Natural Frequency

Author(s):  
Dumitru I. Caruntu ◽  
Jose C. Solis Silva

The nonlinear response of an electrostatically actuated cantilever beam microresonator sensor for mass detection is investigated. The excitation is near the natural frequency. A first order fringe correction of the electrostatic force, viscous damping, and Casimir effect are included in the model. The dynamics of the resonator is investigated using the Reduced Order Model (ROM) method, based on Galerkin procedure. Steady-state motions are found. Numerical results for uniform microresonators with mass deposition and without are reported.

Author(s):  
Dumitru I. Caruntu ◽  
Israel Martinez

The nonlinear response of an electrostatically actuated cantilever beam microresonator is investigated. The AC voltage is of frequency near resonator’s natural frequency. A first order fringe correction of the electrostatic force and viscous damping are included in the model. The dynamics of the resonator is investigated using the Reduced Order Model (ROM) method, based on Galerkin procedure. Steady-state motions are found. Numerical results for the uniform microresonator are compared with those obtained via the Method of Multiple Scales (MMS).


2011 ◽  
Vol 11 (04) ◽  
pp. 641-672 ◽  
Author(s):  
DUMITRU I. CARUNTU ◽  
MARTIN KNECHT

This paper deals with the nonlinear response of electrostatically actuated cantilever beam microresonators near-half natural frequency. A first-order fringe correction of the electrostatic force, viscous damping, and Casimir effect are included in the model. Both forces, electrostatic and Casimir, are nonlinear. The dynamics of the resonator is investigated using the method of multiple scales (MMS) in a direct approach of the problem. The reduced order model (ROM) method, based on Galerkin procedure, is used as well. Steady-state motions are found. Numerical simulations are conducted for uniform microresonators. The influences of damping, actuation, and fringe effect on the resonator response are found.


Author(s):  
Dumitru I. Caruntu ◽  
Le Luo

This paper deals with electrostatically actuated Carbon Nano-Tubes (CNT) cantilevers using Reduced Order Model method. The system consists of a CNT parallel to a ground plate. An alternating current (AC) voltage is considered between the two. The CNT undergoes an oscillatory motion due to the electrostatic force generated by the voltage. Another two forces act on the CNT, namely a damping force, and a van der Waals force due to gaps less than 50 nm. The Method of Multiple Scales (MMS) and the Reduced Order Model (ROM) method (using AUTO solver) are used to investigate the system under soft excitations and/or weak nonlinearities. The frequency response is found in the case of AC near half natural frequency.


Author(s):  
Dumitru I. Caruntu ◽  
Israel Martinez ◽  
Martin W. Knecht

This paper uses the reduced order model (ROM) method to investigate the nonlinear-parametric dynamics of electrostatically actuated microelectromechanical systems (MEMS) cantilever resonators under soft alternating current (AC) voltage of frequency near half natural frequency. This voltage is between the resonator and a ground plate and provides the actuation for the resonator. Fringe effect and damping forces are included. The resonator is modeled as a Euler-Bernoulli cantilever. ROM convergence shows that the five terms model accurately predicts the steady states of the resonator for both small and large amplitudes and the pull-in phenomenon either when frequency is swept up or down. It is found that the MEMS resonator loses stability and undergoes a pull-in phenomenon (1) for amplitudes about 0.5 of the gap and a frequency less than half natural frequency, as the frequency is swept up, and (2) for amplitudes of about 0.87 of the gap and a frequency about half natural frequency, as the frequency is swept down. It also found that there are initial amplitudes and frequencies lower than half natural frequency for which pull-in can occur if the initial amplitude is large enough. Increasing the damping narrows the escape band until no pull-in phenomenon can occur, only large amplitudes of about 0.85 of the gap being reached. If the damping continues to increase the peak amplitude decreases and the resonator experiences a linear dynamics like behavior. Increasing the voltage enlarges the escape band by shifting the sweep up bifurcation frequency to lower values; the amplitudes of losing stability are not affected. Fringe effect affects significantly the behavior of the MEMS resonator. As the cantilever becomes narrower the fringe effect increases. This slightly enlarges the escape band and increases the sweep up bifurcation amplitude. The method of multiple scales (MMS) fails to accurately predict the behavior of the MEMS resonator for any amplitude greater than 0.45 of the gap. Yet, for amplitudes less than 0.45 of the gap MMS predictions match perfectly ROM predictions.


Author(s):  
Dumitru I. Caruntu ◽  
Christian Reyes

This paper investigates the frequency response of microplates under electrostatic actuation. The microplate is parallel to a fixed ground plate. The electrostatic force that actuates the system is given by both Alternate Current (AC) and Direct Current (DC) voltages. The AC frequency is set to be near half natural frequency of the structure. Damping influence is also investigated in this paper. The method of investigation is Reduced Order Model. The effects of various parameters on the response of the structure are reported.


Author(s):  
Dumitru I. Caruntu ◽  
Martin W. Knecht

Bio-MEMS/NEMS resonator sensors near twice natural frequency for mass detection are investigated. Electrostatic force along with fringe correction and Casimir effect are included in the model. They introduce parametric nonlinear terms in the system. The partial-differential equation of motion of the system is solved by using the method of multiple scales. A direct approach of the problem is then used. Two approximation problems resulting from the direct approach are solved. Phase-amplitude relationship is obtained. Numerical results for uniform electrostatically actuated micro resonator sensors are reported.


Author(s):  
Dumitru I. Caruntu ◽  
Le Luo

This paper investigates electrostatically actuated Carbon Nano-Tubes (CNT) cantilevers biosensors using the Reduced Order Model (ROM) method. Forces acting on the CNT are electrostatic, damping, and van der Waals. The electrostatic actuation is given by soft AC voltage. Van der Waals forces are significant for gaps between the CNT and a ground plate lower than 100 nm. Both forces electrostatic and van der Waals are nonlinear. CNT undergoes nonlinear parametric dynamics. ROM is used to investigate the system under soft excitations and/or weak nonlinearities. The frequency-amplitude response is found in the case of primary resonance and compared to the Method of Multiple Scales (MMS). The CNT biosensor is to be used for mass detection applications.


Author(s):  
Dumitru I. Caruntu ◽  
Martin Knecht

This paper deals with sensitivity of electrostatically actuated Bio-MEMS/NEMS resonator sensors near half natural frequency for mass detection for applications in medicine and biology. Electrostatic force along with fringe correction and Casimir effect are included in the model. They introduce parametric nonlinear terms in the system. The partial-differential equation of motion of the system is solved by using the method of multiple scales. A direct approach of the problem is then used. Two approximation problems resulting from the direct approach are solved. The phase-amplitude relationship is obtained. Numerical results for uniform electrostatically actuated micro resonator sensors are provided. An additional mass consisting of a film with a thickness of 100 nm (virus size), and a density of 0.43 of the density of the microsensor, has been added to the sensor. The additional mass shifted the amplitude-frequency curve of the sensor to lower frequencies.


Author(s):  
Dumitru I. Caruntu ◽  
Le Luo

This paper deals with electrostatically actuated Carbon Nano-Tubes (CNT) cantilevers using Reduced Order Model method. There are three kinds of forces acting on the CNT cantilever: electrostatic, elastostatic, and van der Waals. The van der Waals forces are significant for values of 50 nm or lower of the gap between the CNT and the ground plate. As both forceselectrostatic and van der Waals are nonlinear, and the CNT electrostatic actuation is given by AC voltage, the CNT undergoes nonlinear parametric dynamics. The Method of Multiple Scales (MMS), Reduced Order Model (ROM) and AUTO are used to investigate the system under soft excitations and/or weak nonlinearities. The frequency-amplitude and frequency-phase behaviors are found in the case of resonance near half natural frequency.


Author(s):  
Dumitru I. Caruntu ◽  
Christian Reyes

This paper deals with superharmonic resonance of electrostatically actuated MEMS resonator sensors. The system consists of a MEMS cantilever on top of a parallel ground plate. An AC voltage of frequency near one fourth the natural frequency of the resonator provides the electrostatic force of actuation. The frequency response of the superharmonic resonance of the structure is investigated using two term Reduced Order Model (ROM) method.


Sign in / Sign up

Export Citation Format

Share Document