microelectromechanical systems
Recently Published Documents


TOTAL DOCUMENTS

1887
(FIVE YEARS 358)

H-INDEX

73
(FIVE YEARS 8)

2022 ◽  
Vol 11 (1) ◽  
pp. 15-20
Author(s):  
Parviz Saeidi ◽  
Bernhard Jakoby ◽  
Gerald Pühringer ◽  
Andreas Tortschanoff ◽  
Gerald Stocker ◽  
...  

Abstract. Plasmonic waveguides have attracted much attention owing to the associated high field intensity at the metal–dielectric interface and their ability to confine the modes at the nanometer scale. At the same time, they suffer from relatively high propagation loss, which is due to the presence of metal. Several alternative materials have been introduced to replace noble metals, such as transparent conductive oxides (TCOs). A particularly popular TCO is indium tin oxide (ITO), which is compatible with standard microelectromechanical systems (MEMS) technology. In this work, the feasibility of ITO as an alternative plasmonic material is investigated for infrared absorption sensing applications: we numerically design and optimize an ITO-based plasmonic slot waveguide for a wavelength of 4.26 µm, which is the absorption line of CO2. Our optimization is based on a figure of merit (FOM), which is defined as the confinement factor divided by the imaginary part of the effective mode index (i.e., the intrinsic damping of the mode). The obtained optimal FOM is 3.2, which corresponds to 9 µm and 49 % for the propagation length (characterizing the intrinsic damping) and the confinement factor, respectively.


2022 ◽  
Vol 15 ◽  
Author(s):  
Hui Ho Vanessa Chang ◽  
Barbara J. Morley ◽  
Kathleen E. Cullen

The functional role of the mammalian efferent vestibular system (EVS) is not fully understood. One proposal is that the mammalian EVS plays a role in the long-term calibration of central vestibular pathways, for example during development. Here to test this possibility, we studied vestibular function in mice lacking a functional α9 subunit of the nicotinic acetylcholine receptor (nAChR) gene family, which mediates efferent activation of the vestibular periphery. We focused on an α9 (−/−) model with a deletion in exons 1 and 2. First, we quantified gaze stability by testing vestibulo-ocular reflex (VOR, 0.2–3 Hz) responses of both α9 (−/−) mouse models in dark and light conditions. VOR gains and phases were comparable for both α9 (−/−) mutants and wild-type controls. Second, we confirmed the lack of an effect from the α9 (−/−) mutation on central visuo-motor pathways/eye movement pathways via analyses of the optokinetic reflex (OKR) and quick phases of the VOR. We found no differences between α9 (−/−) mutants and wild-type controls. Third and finally, we investigated postural abilities during instrumented rotarod and balance beam tasks. Head movements were quantified using a 6D microelectromechanical systems (MEMS) module fixed to the mouse’s head. Compared to wild-type controls, we found head movements were strikingly altered in α9 (−/−) mice, most notably in the pitch axis. We confirmed these later results in another α9 (−/−) model, with a deletion in the exon 4 region. Overall, we conclude that the absence of the α9 subunit of nAChRs predominately results in an impairment of posture rather than gaze.


Author(s):  
Philippe Martin Tingzon ◽  
Horace Andrew Husay ◽  
Neil Irvin Cabello ◽  
John Jairus Eslit ◽  
Kevin Cook ◽  
...  

Abstract We employ micro-Raman spectroscopy to optically infer the stress experienced by the legs of a bridge-type microelectromechanical systems (MEMS) used in high contrast gratings tunable vertical cavity surface emitting lasers (VCSELs). We then employ micro-photoluminescence (PL) spectroscopy to indirectly measure the air cavity displacement of the same MEMS structure. Results from micro-Raman show that electrostatically actuating the MEMS with a DC bias configuration yields increasing residual stress on the endpoints of the MEMS with values reaching up to 0.8 GPa. We simulated a finite element model via Comsol Multiphysics which agrees with the trend we observe based on our micro-Raman data. Our micro-photoluminescence (PL) spectroscopy showed that change in the air cavity of the VCSEL structure results in a change in the full width of the PL peak emitted by the layer consisting of 4 pairs of Distributed Bragg Reflectors (DBRs). The change in the full width of the PL peak was due to the change in the optical cavity induced by displacing the MEMS via externally applied bias and agrees with our transfer matrix convolution simulation. These optical characterization tools can be used for failure analysis, MEMS design improvements, and monitoring of MEMS tunable VCSEL devices for mass production and manufacturing.


Drones ◽  
2022 ◽  
Vol 6 (1) ◽  
pp. 17
Author(s):  
Carlo Giorgio Grlj ◽  
Nino Krznar ◽  
Marko Pranjić

Unmanned Aerial Vehicles have advanced rapidly in the last two decades with the advances in microelectromechanical systems (MEMS) technology. It is crucial, however, to design better power supply technologies. In the last decade, lithium polymer and lithium-ion batteries have mainly been used to power multirotor UAVs. Even though batteries have been improved and are constantly being improved, they provide fairly low energy density, which limits multirotors’ UAV flight endurance. This problem is addressed and is being partially solved by using docking stations which provide an aircraft to land safely, charge (or change) the batteries and to take-off as well as being safely stored. This paper focuses on the work carried out in the last decade. Different docking stations are presented with a focus on their movement abilities. Rapid advances in computer vision systems gave birth to precise landing systems. These algorithms are the main reason that docking stations became a viable solution. The authors concluded that the docking station solution to short ranges is a viable option, and numerous extensive studies have been carried out that offer different solutions, but only some types, mainly fixed stations with storage systems, have been implemented and are being used today. This can be seen from the commercially available list of docking stations at the end of this paper. Nevertheless, it is important to be aware of the technologies being developed and implemented, which can offer solutions to a vast number of different problems.


2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Naoki Inomata ◽  
Yuka Tonsho ◽  
Takahito Ono

AbstractThe quality factor (Q-factor) is an important parameter for mechanical resonant sensors, and the optimal values depend on its application. Therefore, Q-factor control is essential for microelectromechanical systems (MEMS). Conventional methods have some restrictions, such as additional and complicated equipment or nanoscale dimensions; thus, structural methods are one of the reasonable solutions for simplifying the system. In this study, we demonstrate Q-factor control using a variable phononic bandgap by changing the length of the periodic microstructure. For this, silicon microstructure is used because it has both periodicity and a spring structure. The bandgap change is experimentally confirmed by measuring the Q-factors of mechanical resonators with different resonant frequencies. The bandgap range varies depending on the extended structure length, followed by a change in the Q-factor value. In addition, the effects of the periodic structure on the Q-factor enhancement and the influence of stress on the structural length were evaluated. Although microstructures can improve the Q-factors irrespective of periodicity; the result of the periodic microstructure is found to be efficient. The proposed method is feasible as the novel Q-factor control technique has good compatibility with conventional MEMS.


Micromachines ◽  
2022 ◽  
Vol 13 (1) ◽  
pp. 104
Author(s):  
Shahrzad Forouzanfar ◽  
Nezih Pala ◽  
Chunlei Wang

The electrochemical label-free aptamer-based biosensors (also known as aptasensors) are highly suitable for point-of-care applications. The well-established C-MEMS (carbon microelectromechanical systems) platforms have distinguishing features which are highly suitable for biosensing applications such as low background noise, high capacitance, high stability when exposed to different physical/chemical treatments, biocompatibility, and good electrical conductivity. This study investigates the integration of bipolar exfoliated (BPE) reduced graphene oxide (rGO) with 3D C-MEMS microelectrodes for developing PDGF-BB (platelet-derived growth factor-BB) label-free aptasensors. A simple setup has been used for exfoliation, reduction, and deposition of rGO on the 3D C-MEMS microelectrodes based on the principle of bipolar electrochemistry of graphite in deionized water. The electrochemical bipolar exfoliation of rGO resolves the drawbacks of commonly applied methods for synthesis and deposition of rGO, such as requiring complicated and costly processes, excessive use of harsh chemicals, and complex subsequent deposition procedures. The PDGF-BB affinity aptamers were covalently immobilized by binding amino-tag terminated aptamers and rGO surfaces. The turn-off sensing strategy was implemented by measuring the areal capacitance from CV plots. The aptasensor showed a wide linear range of 1 pM–10 nM, high sensitivity of 3.09 mF cm−2 Logc−1 (unit of c, pM), and a low detection limit of 0.75 pM. This study demonstrated the successful and novel in-situ deposition of BPE-rGO on 3D C-MEMS microelectrodes. Considering the BPE technique’s simplicity and efficiency, along with the high potential of C-MEMS technology, this novel procedure is highly promising for developing high-performance graphene-based viable lab-on-chip and point-of-care cancer diagnosis technologies.


Sensors ◽  
2021 ◽  
Vol 22 (1) ◽  
pp. 316
Author(s):  
Sławomir Kciuk ◽  
Edyta Krzystała ◽  
Arkadiusz Mężyk ◽  
Paweł Szmidt

This paper describes the development and application of an autonomous register and measurement system (ARMS), and the application of microelectromechanical systems (MEMS) accelerometers to the assessment of blast threat to armored vehicle crews. Taking measurements with reference to an explosion is one of the principal issues in the protection of crews of special vehicles. The proposed ARMS reduces research costs and contributes to the development of an autonomous, wireless test stand, applicable in various research areas and industry. The ARMS performs data acquisition with simultaneous measurement in multiple channels. The maximum sampling rate is 100 kHz and the sensor range is ±500 g. This solution is an alternative to cable systems, which have a high energy demand. The functionality of the developed autonomous measuring system is demonstrated experimentally. The paper concludes with a field study of the proposed system and the application of MEMS accelerometers via a mine blast test of a military vehicle at level 4 of STANAG 4569.


2021 ◽  
Vol 11 (4) ◽  
pp. 478-499
Author(s):  
I.S. Tkachenko ◽  

One of the key areas of modern world cosmonautics is the development of cluster space systems for various purposes, consisting of a large number of functioning spacecraft. This became possible due to a decrease in the mass of spacecraft due to the creation and use of new materials, the development of electronics and microelectromechanical systems, the use of the group launch method, the development of multi-agent technologies and inter-satellite communication sys-tems. There are projects of systems consisting of a large number of space objects, such as OneWeb, Planet, Starlink, Satellogic, etc. The main classes of devices used to create such multi-satellite systems are small satellites, including the number of micro (up to 100 kg) and nano (up to 10-15 kg) classes, which have significant advantages over heavy space-craft, especially in terms of the timing and cost of their creation. The deployment of multi-satellite constellations, in-cluding hundreds and thousands of satellites, requires fundamentally new approaches to the creation of spacecraft and the system as a whole at all stages of the life cycle. The article discusses the key technologies used to create multi-satellite orbital constellations based on small satellites at different stages of the life cycle - from the early stages of de-sign to the stage of operation and disposal (information from orbit). The experience of a joint project of Samara Univer-sity and the Progress Rocket and Space Center on the creation of a constellation of small spacecraft of the AIST series is presented.


Micromachines ◽  
2021 ◽  
Vol 13 (1) ◽  
pp. 23
Author(s):  
Corina Bîrleanu ◽  
Marius Pustan ◽  
Florina Șerdean ◽  
Violeta Merie

Nanotribological studies of thin films are needed to develop a fundamental understanding of the phenomena that occur to the interface surfaces that come in contact at the micro and nanoscale and to study the interfacial phenomena that occur in microelectromechanical systems (MEMS/NEMS) and other applications. Atomic force microscopy (AFM) has been shown to be an instrument capable of investigating the nanomechanical behavior of many surfaces, including thin films. The measurements of tribo-mechanical behavior for MEMS materials are essential when it comes to designing and evaluating MEMS devices. A great deal of research has been conducted to evaluate the efficiency and reliability of different measurements methods for mechanical properties of MEMS material; nevertheless, the technologies regarding manufacturing and testing MEMS materials are not fully developed. The objectivesof this study are to focus on the review of the mechanical and tribological advantages of thin film and to highlight the experimental results of some thin films to obtain quantitative analyses, the elastic/plastic response and the nanotribological behavior. The slight fluctuation of the results for common thin-film materials is most likely due to the lack of international standardization for MEMS materials and for the methods used to measure their properties.


2021 ◽  
Author(s):  
Mikhail

High sensitive (S = 11.2 ± 1.8 mV/V/kPa with nonlinearity error 2KNL = 0.15 ± 0.09%/FS) small-sized (4.00x4.00 mm2) silicon pressure sensor chip utilizing new electrical circuit for microelectromechanical systems (MEMS) in the form of differential amplifier with negative feedback loop (PDA-NFL) for 5 kPa differential was developed. The advantages are demonstrated in the array of output characteristics, which prove the relevance of the presented development, relative to modern developments of pressure sensors with Wheatstone bridge electrical circuit for 5 kPa range.


Sign in / Sign up

Export Citation Format

Share Document