A Critical Review on the Numerical Methods of Two-Phase Flows

Author(s):  
Muhammet Balcilar ◽  
Ahmet Selim Dalkiliç ◽  
Ali Çelen ◽  
Nurullah Kayaci ◽  
Somchai Wongwises

The two-phase flow processes play a significant role in the heat transfer processes in the chemical and power industry, including in nuclear power plants. This study is a critical review on the determination of the heat transfer characteristics of pure refrigerants flowing in vertical and horizontal tubes. The authors’ previous publications on this issue, including the numerical analyses, are summarized here. The lengths of the vertical and horizontal test sections varied between 0.5 m and 4 m countercurrent flow double-tube heat exchangers with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The measured data are compared to numerical predictions based on the solution of the artificial intelligence methods and CFD analyses for the condensation and evaporation processes in the smooth and enhanced tubes. The theoretical solutions are related to the design of passive containment cooling systems (PCCS) in simplified water boiling reactors (SWBR). A genetic algorithm (GA), various artificial neural network models (ANN) such as multilayer perceptron (MLP), radial basis networks (RBFN), generalized regression neural network (GRNN), and adaptive neuro-fuzzy inference system (ANFIS), and various optimization techniques such as unconstrained nonlinear minimization algorithm-Nelder-Mead method (NM), non-linear least squares error method (NLS), and Fluent CFD program are used in the numerical solution. It is shown that the heat transfer characteristics of laminar and turbulent condensing and evaporating film flows such as heat transfer coefficient and pressure drop can be predicted by means of numerical analyses reasonably well if there is a sufficient amount of reliable experimental data. Regression analysis gave convincing correlations, and the most suitable coefficients of the proposed correlations are depicted as compatible with the large number of experimental data by means of the computational numerical methods. Dependency of the output of the ANNs from various numbers of input values is also shown for condensing and evaporating flows.

Author(s):  
Ahmet Selim Dalkiliç ◽  
Ali Celen ◽  
Mohamed M. Awad ◽  
Somchai Wongwises

Heat exchangers using in-tube condensation have great significance in the refrigeration, automotive and process industries. Effective heat exchangers have been rapidly developed due to the demand for more compact systems, higher energy efficiency, lower material costs and other economic incentives. Enhanced surfaces, displaced enhancement devices, swirl-flow devices and surface tension devices improve the heat transfer coefficients in these heat exchangers. This study is a critical review on the determination of the condensation heat transfer coefficient of pure refrigerants flowing in vertical and horizontal tubes. The authors’ previous publications on this issue, including the experimental, theoretical and numerical analyses are summarized here. The lengths of the vertical and horizontal test sections varied between 0.5 m and 4 m countercurrent flow double-tube heat exchangers with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The measured data are compared to theoretical and numerical predictions based on the solution of the artificial intelligence methods and CFD analyses for the condensation process in the smooth and enhanced tubes. The theoretical solutions are related to the design of double tube heat exchangers in refrigeration, air conditioning and heat pump applications. Detailed information on the in-tube condensation studies of heat transfer coefficient in the literature is given. A genetic algorithm (GA), various artificial neural network models (ANN) such as multilayer perceptron (MLP), radial basis networks (RBFN), generalized regression neural network (GRNN), and adaptive neuro-fuzzy inference system (ANFIS), and various optimization techniques such as unconstrained nonlinear minimization algorithm-Nelder-Mead method (NM), non-linear least squares error method (NLS), and Ansys CFD program are used in the numerical solutions. It is shown that the convective heat transfer coefficient of laminar and turbulent condensing film flows can be predicted by means of theoretical and numerical analyses reasonably well if there is a sufficient amount of reliable experimental data. Regression analysis gave convincing correlations, and the most suitable coefficients of the proposed correlations are depicted as compatible with the large number of experimental data by means of the computational numerical methods.


Author(s):  
V. Yu. Kravets ◽  
D. I. Hurov

This paper presents and analyzes experimental data on the total thermal resistances of two-phase miniature thermosyphons with nanofluids; the geometric parameters of the thermosyphons for all experimental samples are identical: total length 700 mm, internal diameter 5 mm. The following nanofluids used as heat carriers are: aqueous nanofluid based on carbon nanotubes, aqueous nanofluid based on synthetic diamond, and aqueous nanofluid based on amorphous carbon. Much attention is also paid to the influence of the filling ratio on the heat transfer characteristics of the thermosyphons. The influence of filling ratio and types of nanofluid on the performance of miniature closed two-phase thermosyphons is demonstrated.


2017 ◽  
Vol 21 (6 Part A) ◽  
pp. 2481-2489 ◽  
Author(s):  
Babak Aghel ◽  
Masoud Rahimi ◽  
Saeed Almasi

This study investigated the heat transfer characteristics of modified two-phase closed thermosyphon (TPCT) using water as the working fluid. In the modified TPCT, to reduce thermal resistance, a small TPCT was inserted inside the adiabatic section. For both the plain and modified thermosyphons the performances were determined at various heat inputs from 71-960 W. The results showed that the modified TPCT had less temperature difference between the evaporator and condenser sections than the plain one. According to the experimental data, in the modified TPCT, the thermal performance increased up to 20% over that of the unmodified one.


1992 ◽  
Vol 114 (4) ◽  
pp. 965-971 ◽  
Author(s):  
H. Shimaoka ◽  
Y. H. Mori

The evaporation of isolated drops (2.1−3.0 mm diameter) of nonazeotropic n-pentane/n-hexane mixtures in the medium of water was observed under pressures of 0.11−0.46 MPa and temperature differences up to 27 K. The mole fractions of n-pentane, x, in the mixtures were set at 0.9, 0.5, 0.1, and 0, to be completed by the condition x = 1 set in a preceding work (Shimaoka and Mori, 1990). Experimental results are presented in terms of the instantaneous rise velocity of, and an expression of instantaneous heat transfer to, each drop evaporating and thereby transforming into a liquid/vapor two-phase bubble and finally into a vapor bubble. The dependencies of the heat transfer characteristics on the pressure, the temperature difference, and x are discussed.


Sign in / Sign up

Export Citation Format

Share Document