Analysis of the Possibility of Water Induction in Turbine From Direct Contact Water Heater at Load Shedding Power

Author(s):  
M. A. Gotovsky ◽  
V. F. Ermolov ◽  
V. E. Mikhailov ◽  
Yu. G. Sukhorukov ◽  
N. N. Trifonov

Direct-contact heaters of feed water are especially popular as low-pressure heaters (LPH). These devices are successfully used in Russia during a long time both for conventional and nuclear power plants. Moreover, abilities of such devices to operate as deaerators led to the development deaeratorless schemes. One of most important conditions of reliable operating of such LPH is the prevention of damage of steam turbines, because of back flow of wet steam to the turbine. In this paper processes of boiling up are considered in direct contact LPH-2 which occur during stopping of turbine and its specific features concerned with dependence of sonic speed two-phase flow on vapor and liquid volumetric portions during flow enter in compensating tubes. Computer analysis showed, that the rate of generation of steam in the superheated water depends on the pressure exceptionally strong. Zone of churn flow regime, which is formed in the upper part of the condensate tank appears very sensitive instrument of flow rate control. As it is shown in such a situation, the system becomes self-governing and will not miss a steam consumption, which leads to the entrance some part of churn regime zone to pressure equalizing tubes. The calculations show that the safety can be ensure even in the conditions when backpressure valve absent. Such the conclusion is confirmed by the experience on operation direct contact LPH in Russian power plants.

Author(s):  
Yumi Yamada ◽  
Toyou Akashi ◽  
Minoru Takahashi

In a lead-bismuth alloy (45%Pb-55%Bi) cooled direct contact boiling water fast reactor (PBWFR), steam can be produced by direct contact of feed water with primary Pb-Bi coolant in the upper core plenum, and Pb-Bi coolant can be circulated by buoyancy forces of steam bubbles. As a basic study to investigate the two-phase flow characteristics in the chimneys of PBWFR, a two-dimensional two-phase flow was simulated by injecting argon gas into Pb-Bi pool in a rectangular vessel (400mm in length, 1500mm in height, 50mm in width), and bubble behaviors were investigated experimentally. Bubble sizes, bubble rising velocities and void fractions were measured using void probes. Argon gas was injected through five nozzles of 4mm in diameter into Pb-Bi at two locations. The experimental conditions are the pressure of atmospheric pressure, Pb-Bi temperatures of 443K, and the flow rate of injection Ar gas is 10, 20, and 30 NL/min. The measured bubble rising velocities were distributed in the range from 1 to 3 m/s. The average velocity was about 0.6 m/s. The measured bubble chord lengths were distributed from 1mm up to 30mm. The average chord length was about 7mm. An analysis was performed by two-dimensional and two-fluid model. The experimental results were compared with the analytical results to evaluate the validity of the analytical model. Although large diameter bubbles were observed in the experiment, the drag force model for spherical bubbles performed better for simulation of the experimental result because of high surface tension force of Pb-Bi.


Author(s):  
Deqi Yu ◽  
Jiandao Yang ◽  
Wei Lu ◽  
Daiwei Zhou ◽  
Kai Cheng ◽  
...  

The 1500-r/min 1905mm (75inch) ultra-long last three stage blades for half-speed large-scale nuclear steam turbines of 3rd generation nuclear power plants have been developed with the application of new design features and Computer-Aided-Engineering (CAE) technologies. The last stage rotating blade was designed with an integral shroud, snubber and fir-tree root. During operation, the adjacent blades are continuously coupled by the centrifugal force. It is designed that the adjacent shrouds and snubbers of each blade can provide additional structural damping to minimize the dynamic stress of the blade. In order to meet the blade development requirements, the quasi-3D aerodynamic method was used to obtain the preliminary flow path design for the last three stages in LP (Low-pressure) casing and the airfoil of last stage rotating blade was optimized as well to minimize its centrifugal stress. The latest CAE technologies and approaches of Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and Fatigue Lifetime Analysis (FLA) were applied to analyze and optimize the aerodynamic performance and reliability behavior of the blade structure. The blade was well tuned to avoid any possible excitation and resonant vibration. The blades and test rotor have been manufactured and the rotating vibration test with the vibration monitoring had been carried out in the verification tests.


Author(s):  
Enrico Deri ◽  
Joël Nibas ◽  
Olivier Ries ◽  
André Adobes

Flow-induced vibrations of Steam Generator tube bundles are a major concern for the operators of nuclear power plants. In order to predict damages due to such vibrations, EDF has developed the numerical tool GeViBus, which allows one to asses risk and thereafter to optimize the SG maintenance policy. The software is based on a semi analytical model of fluid-dynamic forces and dimensionless fluid force coefficients which need to be assessed by experiment. The database of dimensionless coefficients is updated in order to cover all existing tube bundle configurations. Within this framework, a new test rig was presented in a previous conference with the aim of assessing parallel triangular tube arrangement submitted to a two-phase cross-flow. This paper presents the result of the first phase of the associated experiments in terms of force coefficients and two-phase flow excitation spectra for both in-plane and out-of-plane vibration.


2020 ◽  
Vol 328 ◽  
pp. 01009
Author(s):  
František Világi ◽  
Branislav Knížat ◽  
Róbert Olšiak ◽  
Marek Mlkvik ◽  
Peter Mlynár ◽  
...  

The natural circulation helium loop is an experimental facility designed for the research of the possibility of utilizing natural convection cooling for the case of decay heat removal from a fast nuclear reactor. This concept would bring an improved automated safety system for future nuclear power plants operating a gas-cooled reactor. The article presents a new possibility of direct use of energy conservation laws in a 1D simulation of natural circulation loops. The calculation is performed by a triple iteration process, nested into each other. The results of the calculations showed good agreement with the measurements at steady state. A calculation with the proposed model at unsteady state is not yet possible, especially because of the exclusion of heat accumulation into the material.


Author(s):  
Nicola Maceli ◽  
Lorenzo Arcangeli ◽  
Andrea Arnone

Abstract The whole energy market, from production plants to end-users, is marked by a strong impulse towards a sustainable use of raw materials and resources, and a reduction of its carbon foot-print. Increasing the split of energy produced with renewables, improving the efficiency of the power plants and reducing the waste of energy appear to be mandatory steps to reach the goal of sustainability. The steam turbines are present in the power generation market with different roles: they are used in fossil, combined cycles, geothermal and concentrated solar plants, but also in waste-to-energy and heat recovery applications. Therefore, they still play a primary role in the energy production market. There are many chances for efficiency improvement in steam turbines, and from a rational point of view, it is important to consider that the LP section contributes to the overall power delivered by the turbine typically by around 40% in industrial power generation. Therefore, the industry is more than ever interested in developing methodologies capable of providing a reliable estimate of the LP stages efficiency, while reducing development costs and time. This paper presents the results obtained using a CFD commercial code with a set of user defined subroutines to model the effects of non-equilibrium steam evolution, droplets nucleation and growth. The numerical results have been compared to well-known test cases available in literature, to show the effects of different modeling hypotheses. The paper then focuses on a test case relevant to a cascade configuration, to show the code capability in terms of bladerow efficiency prediction. Finally, a comprehensive view of the obtained results is done through comparison with existing correlations.


Energies ◽  
2019 ◽  
Vol 13 (1) ◽  
pp. 109 ◽  
Author(s):  
René Manthey ◽  
Frances Viereckl ◽  
Amirhosein Moonesi Shabestary ◽  
Yu Zhang ◽  
Wei Ding ◽  
...  

Passive safety systems are an important feature of currently designed and constructed nuclear power plants. They operate independent of external power supply and manual interventions and are solely driven by thermal gradients and gravitational force. This brings up new needs for performance and reliably assessment. This paper provides a review on fundamental approaches to model and analyze the performance of passive heat removal systems exemplified for the passive heat removal chain of the KERENA boiling water reactor concept developed by Framatome. We discuss modeling concepts for one-dimensional system codes such as ATHLET, RELAP and TRACE and furthermore for computational fluid dynamics codes. Part I dealt with numerical and experimental methods for modeling of condensation inside the emergency condenser and on the containment cooling condenser. This second part deals with boiling and two-phase flow instabilities.


Environments ◽  
2019 ◽  
Vol 6 (11) ◽  
pp. 120
Author(s):  
Luca Albertone ◽  
Massimo Altavilla ◽  
Manuela Marga ◽  
Laura Porzio ◽  
Giuseppe Tozzi ◽  
...  

Arpa Piemonte has been carrying out, for a long time, controls on clearable materials from nuclear power plants to verify compliance with clearance levels set by ISIN (Ispettorato Nazionale per la Sicurezza Nucleare e la Radioprotezione - National Inspectorate for Nuclear Safety and Radiation Protection) in the technical prescriptions attached to the Ministerial Decree decommissioning authorization or into category A source authorization (higher level of associated risk, according to the categorization defined in the Italian Legislative Decree No. 230/95). After the experience undertaken at the “FN” (Fabbricazioni Nucleari) Bosco Marengo nuclear installation, some controls have been conducted at the Trino nuclear power plant “E. Fermi,” “LivaNova” nuclear installation based in Saluggia, and “EUREX” (Enriched Uranium Extraction) nuclear installation, also based in Saluggia, according to modalities that envisage, as a final control, the determination of γ-emitting radionuclides through in situ gamma spectrometry measurements. Clearance levels’ compliance verification should be performed for all radionuclides potentially present, including those that are not easily measurable (DTM, Difficult To Measure). It is therefore necessary to carry out upstream, based on a representative number of samples, those radionuclides’ determination in order to estimate scaling factors (SF), defined through the logarithmic average of the ratios between the i-th DTM radionuclide concentration and the related key nuclide. Specific radiochemistry is used for defining DTMs’ concentrations, such as Fe-55, Ni-59, Ni-63, Sr-90, Pu-238, and Pu-239/Pu-240. As a key nuclide, Co-60 was chosen for the activation products (Fe-55, Ni-59, Ni-63) and Cs-137 for fission products (Sr-90) and plutonium (Pu- 238, Pu-239/Pu-240, and Pu-241). The presence of very low radioactivity concentrations, often below the detection limits, can make it difficult to determine the related scaling factors. In this work, the results obtained and measurements’ acceptability criteria are presented, defined with ISIN, that can be used for confirming or excluding a radionuclide presence in the process of verifying clearance levels’ compliance. They are also exposed to evaluations regarding samples’ representativeness chosen for scaling factors’ assessment.