Hemodynamic Environment and Occlusion Time of Tandem Intracranial Aneurysms Treated With Flow Diverters

Author(s):  
Fernando Mut ◽  
Esteban Scrivano ◽  
Pedro Lylyk ◽  
Juan R. Cebral

The use of flow diverting devices to treat complex intracranial aneurysms difficult to treat with coils and clips has recently received substantial attention. Initial experiences with increasing numbers of patients have been carried out with promising results [1]. However, it is still difficult to predict the outcome and/or the aneurysm occlusion time after treatment with flow diverters. The purpose of this work was to relate the hemodynamic environment created immediately after treatment and the occlusion period of a pair of tandem aneurysms.

2019 ◽  
Vol 25 (6) ◽  
pp. 671-680 ◽  
Author(s):  
Junfan Chen ◽  
Yisen Zhang ◽  
Zhongbin Tian ◽  
Wenqiang Li ◽  
Qianqian Zhang ◽  
...  

Background Intracranial aneurysms are increasingly being treated by the placement of flow diverters; however, the factors affecting the outcome of aneurysms treated using flow diverters remain unclarified. Methods The present study investigated 94 aneurysms treated with pipeline embolisation device placement, and used a computational fluid dynamics method to explore the factors influencing the outcome of aneurysms. Results Seventy-six completely occluded aneurysms and 18 incompletely occluded aneurysms were analysed. Before treatment, inflow jets were found in 13 (72.2%) aneurysms in the incompletely occluded group and 34 (44.7%) in the completely occluded group ( P = 0.292). After deployment of the pipeline embolisation device, inflow jets remained in nine (50%) aneurysms in the incompletely occluded group and nine (11.8%) in the completely occluded group ( P = 0.001). In the incompletely occluded group, regions with inflow jets after treatment corresponded with the patent areas shown on follow-up digital subtraction angiography. The mean reduction ratios of velocity in the whole aneurysm and on the neck plane were lower in the incompletely occluded than in the completely occluded group ( P = 0.003; P = 0.017). Multivariate analysis revealed that the only independent risk factors for incomplete aneurysm occlusion were the reduction ratios of velocity (in the whole aneurysm, threshold 0.362, P = 0.005; on the neck plane, threshold 0.273, P = 0.015). Conclusions After pipeline embolisation device placement, reduction ratios of velocity in the whole aneurysm of less than 0.362 and on the neck plane of less than 0.273 are significantly associated with a greater risk of aneurysm incomplete occlusion. In addition, the persistence of inflow jets in aneurysms is associated with incomplete occlusion in the inflow jet area.


2012 ◽  
Vol 73 (suppl_1) ◽  
pp. ons80-ons85 ◽  
Author(s):  
Ketan R. Bulsara ◽  
Gregory A. Kuzmik ◽  
Ryan Hebert ◽  
Vincent Cheung ◽  
Charles C. Matouk ◽  
...  

Abstract BACKGROUND: Small, blister-like aneurysms (BLAs), by virtue of their unique morphology, are difficult to treat with conventional modalities. The use of oversized self-expanding stents as monotherapy for BLAs is a relatively new and promising concept that warrants further investigation. OBJECTIVE: To clarify the role of oversized self-expanding stents as monotherapy for BLAs. METHODS: Five consecutive patients were treated for BLAs with oversized self-expanding stents alone by the senior author (K.R.B.). We report on their clinical and radiographic outcomes. RESULTS: All 5 patients in our series were discharged in good clinical condition. Complete aneurysm occlusion was observed in all patients at the time of most recent radiographic follow-up. Mean follow-up time was 13.6 months (range, 1 month to 4.5 years). CONCLUSION: The use of oversized self-expanding stents to redirect flow away from aneurysms is an effective option for patients with BLAs. This approach represents an alternative to the use of flow diverters.


2021 ◽  
Vol 11 (3) ◽  
pp. 349
Author(s):  
Michelle F. M. ten Brinck ◽  
Luigi Rigante ◽  
Viktoria E. Shimanskaya ◽  
Ronald H. M. A. Bartels ◽  
Frederick J. A. Meijer ◽  
...  

Background: Treatment of intracranial aneurysms with flow diverters (FDs) showed promising results. However, a subset of patients treated for posterior communicating artery (PComA) aneurysms has variable occlusion rates. Especially the fetal type-associated PComA aneurysms seemed to respond differently to treatment. We analyze our series of fetal type PComA aneurysms treated with a FD. The literature on this subject is reviewed. Methods: Data from patients treated with FD for all PComA aneurysms at the RadboudUMC Nijmegen were retrospectively analysed. Primary end-point was complete aneurysm occlusion at six months. Secondary end-points were clinical outcome, treatment safety, and results of secondary treatment after non-closure. The results for the fetal PComA aneurysms were compared to the literature. Results: Nineteen consecutive patients harboring 21 PComA aneurysms were treated. Three aneurysms had ipsilateral fetal type PCA (14.3%). Overall, none of the fetal type PcomA aneurysm showed complete occlusion versus 77.8% of the others (p = 0.03). Mortality and permanent morbidity rates were respectively 5.3% and 0%. Conclusions: FD treatment for PComA aneurysm with fetal type circulation seemed to be less effective compared to other types of PComA aneurysms. Flow characteristics at the PComA bifurcation are thought to be causative Alternative strategies should be considered as first line treatment.


2021 ◽  
pp. neurintsurg-2021-018054
Author(s):  
Ricardo A Hanel ◽  
Andre Monteiro ◽  
Peter K Nelson ◽  
Demetrius K Lopes ◽  
David F Kallmes

BackgroundFlow diverters have revolutionized the treatment of intracranial aneurysms. Nevertheless, some aneurysms fail to occlude with flow diversion. The Prospective Study on Embolization of Intracranial Aneurysms with the Pipeline Device (PREMIER) was a prospective, multicenter and single-arm trial of small and medium wide-necked unruptured aneurysms. In the current study, we evaluate the predictors of treatment failure in the PREMIER cohort.MethodsWe analyzed PREMIER patients who had incomplete occlusion (Raymond-Roy >1) at 1 year angiographic follow-up and compared them with those who achieved Raymond-Roy 1, aiming to identify predictors of treatment failure.Results25 aneurysms demonstrated incomplete occlusion at 1 year. There was a median reduction of 0.9 mm (IQR 0.41–2.43) in maximum diameter between pre-procedure and 1 year measurements, with no aneurysmal hemorrhage. Patients with incomplete occlusion were significantly older than those with complete occlusion (p=0.011). Smoking (p=0.045) and C6 segment location (p=0.005) were significantly associated with complete occlusion, while location at V4 (p=0.01) and C7 (p=0.007) and involvement of a side branch (p<0.001) were significantly associated with incomplete occlusion. In multivariable logistic regression, significant predictors of incomplete occlusion were non-smoker status (adjusted OR 4.49, 95% CI 1.11 to 18.09; p=0.03) and side branch involvement (adjusted OR 11.68, 95% CI 3.84 to 35.50; p<0.0001), while C6 location had reduced odds of incomplete occlusion (adjusted OR 0.29, 95% CI 0.10 to 0.84; p=0.02).ConclusionsThe results of our study are consistent with previous retrospective series and warrant consideration for technique adaptations to achieve higher occlusion rates. Further follow-up is needed to assess progression of aneurysm occlusion and clinical behavior in these cases.


2021 ◽  
pp. 159101992110034
Author(s):  
Andre Monteiro ◽  
Demetrius K Lopes ◽  
Amin Aghaebrahim ◽  
Ricardo Hanel

Purpose Flow-diverters have revolutionized the endovascular treatment of intracranial aneurysms, offering a durable solution to aneurysms with high recurrence rates after conventional stent-assisted coiling. Events that occur after treatment with flow-diversion, such as in-stent stenosis (ISS) are not well understood and require further assessment. After assessing an animal model with Optical Coherence Tomography (OCT), we propose a concept that could explain the mechanism causing reversible ISS after treatment of intracranial aneurysms with flow-diverters. Methods Six Pipeline Flex embolization devices (PED-Flex), six PED with Shield technology (PED-Shield), and four Solitaire AB devices were implanted in the carotid arteries (two stents per vessel) of four pigs. Intravascular optical coherence tomography (OCT) and digital subtraction angiography (DSA) images obtained on day 21 were compared to histological specimens. Results A case of ISS in a PED-Flex device was assessed with OCT imaging. Neointima with asymmetrical topography completely covering the PED struts was observed. Histological preparations of the stenotic area demonstrated thrombus on the surface of device struts, covered by neointima. Conclusion This study provides a plausible concept for reversible ISS in flow-diverters. Based on an observation of a previous experiment, we propose that similar cases of ISS are related to thrombus presence underneath endothelization, but further experiments focused on this phenomenon are needed. Optical Coherence Tomography will be useful tool when available for clinical use.


2021 ◽  
pp. 159101992110251
Author(s):  
Jennifer Ayers-Ringler ◽  
Praveen Kolumam Parameswaran ◽  
Zenith Khashim ◽  
Daying Dai ◽  
Yong-Hong Ding ◽  
...  

Background Flow diverters (FDs) are an effective treatment for intracranial aneurysms, though not free from hemorrhagic complications. A previous study demonstrated increased vascular contractility after FD-implantation as a potential mechanism of distal complications. Our study aimed to investigate whether L-arginine medication affects vascular contractility following FD deployment in a rabbit model. Methods FDs were implanted in the aorta of normal rabbits (+FD, n = 10), with sham-operated aorta as controls (n = 5). L-Arginine was given in the drinking water (2.25% L-arginine hydrochloride) of half of the +FD animals (+FD/+Arg). Force contraction vascular contractility studies were performed on the aortic rings proximal and distal to the FD using an organ bath. Total eNOS, eNOS(pS1177), eNOS(pT495), COX-2, and S100A4 were quantified by western analysis on total protein lysates from aortic segments, normalizing to GAPDH. Results Mean vascular contractility was 53% higher in distal relative to proximal aortic segments (P = 0.0038) in +FD animals, but were not significantly different in +FD/+Arg animals, or in sham-operated controls. The +FD animals expressed significantly reduced levels of eNOS(pS1177) than sham-operated controls (P = 0.0335), while both the +FD and +FD/+Arg groups had reduced levels of eNOS(pT495) relative to sham-operated controls (P = 0.0331 and P = 0.0311, respectively). Conclusion These results suggest that L-arginine medication reduces distal vascular contractility after FD treatment via nitric oxide production and thus might mitigate risk for downstream complications.


2021 ◽  
pp. 159101992110279
Author(s):  
Muhammad Waqas ◽  
Rimal H Dossani ◽  
Modhi Alkhaldi ◽  
Jocelyn Neveu ◽  
Justin M Cappuzzo ◽  
...  

Introduction The Flow Redirection Endoluminal Device (FRED; MicroVention) is a dual-layered flow diverter used for the treatment of intracranial aneurysms. The objective of this systematic review was to compile device-related safety and effectiveness data. Methods The literature from January 1, 2013 to April 30, 2021 was searched for studies describing use of the FRED for intracranial aneurysm treatment irrespective of aneurysm location and morphology. The review included anterior and posterior circulation ruptured and unruptured saccular, fusiform or dissection, and blister aneurysms. MeSH terms related to “flow re-direction endoluminal device” and “FRED for aneurysms” were used. Data related to indication, complications, and rates of aneurysm occlusion were retrieved and analyzed. Results Twenty-two studies with 1729 intracranial aneurysms were included in this review. Overall reported morbidity was 3.9% (range 0–20%). Overall procedure-related mortality was 1.4% (range 0–6%). Complication rates fell into 5 categories: technical (3.6%), ischemic (3.8%), thrombotic or stenotic (6%), hemorrhagic (1.5%), and non-neurological (0.8%). The aneurysm occlusion rate between 0 and 3 months (reported in 11 studies) was 47.8%. The occlusion rate between 4 and 6 months (reported in 14 studies) was 73.8%. Occlusion rates continued to increase to 75.1% at 7–12 months (reported in 10 studies) and 86.6% for follow-up beyond 1 year (reported in 10 studies). Conclusion This review indicated that the FRED is a safe and effective for the treatment of intracranial aneurysms. Future studies should directly compare the FRED with other flow diverters for a better understanding of comparative safety and effectiveness among the different devices.


Sign in / Sign up

Export Citation Format

Share Document