Stenting as Monotherapy for Uncoilable Intracranial Aneurysms

2012 ◽  
Vol 73 (suppl_1) ◽  
pp. ons80-ons85 ◽  
Author(s):  
Ketan R. Bulsara ◽  
Gregory A. Kuzmik ◽  
Ryan Hebert ◽  
Vincent Cheung ◽  
Charles C. Matouk ◽  
...  

Abstract BACKGROUND: Small, blister-like aneurysms (BLAs), by virtue of their unique morphology, are difficult to treat with conventional modalities. The use of oversized self-expanding stents as monotherapy for BLAs is a relatively new and promising concept that warrants further investigation. OBJECTIVE: To clarify the role of oversized self-expanding stents as monotherapy for BLAs. METHODS: Five consecutive patients were treated for BLAs with oversized self-expanding stents alone by the senior author (K.R.B.). We report on their clinical and radiographic outcomes. RESULTS: All 5 patients in our series were discharged in good clinical condition. Complete aneurysm occlusion was observed in all patients at the time of most recent radiographic follow-up. Mean follow-up time was 13.6 months (range, 1 month to 4.5 years). CONCLUSION: The use of oversized self-expanding stents to redirect flow away from aneurysms is an effective option for patients with BLAs. This approach represents an alternative to the use of flow diverters.

2021 ◽  
pp. neurintsurg-2021-018054
Author(s):  
Ricardo A Hanel ◽  
Andre Monteiro ◽  
Peter K Nelson ◽  
Demetrius K Lopes ◽  
David F Kallmes

BackgroundFlow diverters have revolutionized the treatment of intracranial aneurysms. Nevertheless, some aneurysms fail to occlude with flow diversion. The Prospective Study on Embolization of Intracranial Aneurysms with the Pipeline Device (PREMIER) was a prospective, multicenter and single-arm trial of small and medium wide-necked unruptured aneurysms. In the current study, we evaluate the predictors of treatment failure in the PREMIER cohort.MethodsWe analyzed PREMIER patients who had incomplete occlusion (Raymond-Roy >1) at 1 year angiographic follow-up and compared them with those who achieved Raymond-Roy 1, aiming to identify predictors of treatment failure.Results25 aneurysms demonstrated incomplete occlusion at 1 year. There was a median reduction of 0.9 mm (IQR 0.41–2.43) in maximum diameter between pre-procedure and 1 year measurements, with no aneurysmal hemorrhage. Patients with incomplete occlusion were significantly older than those with complete occlusion (p=0.011). Smoking (p=0.045) and C6 segment location (p=0.005) were significantly associated with complete occlusion, while location at V4 (p=0.01) and C7 (p=0.007) and involvement of a side branch (p<0.001) were significantly associated with incomplete occlusion. In multivariable logistic regression, significant predictors of incomplete occlusion were non-smoker status (adjusted OR 4.49, 95% CI 1.11 to 18.09; p=0.03) and side branch involvement (adjusted OR 11.68, 95% CI 3.84 to 35.50; p<0.0001), while C6 location had reduced odds of incomplete occlusion (adjusted OR 0.29, 95% CI 0.10 to 0.84; p=0.02).ConclusionsThe results of our study are consistent with previous retrospective series and warrant consideration for technique adaptations to achieve higher occlusion rates. Further follow-up is needed to assess progression of aneurysm occlusion and clinical behavior in these cases.


2021 ◽  
pp. 159101992110279
Author(s):  
Muhammad Waqas ◽  
Rimal H Dossani ◽  
Modhi Alkhaldi ◽  
Jocelyn Neveu ◽  
Justin M Cappuzzo ◽  
...  

Introduction The Flow Redirection Endoluminal Device (FRED; MicroVention) is a dual-layered flow diverter used for the treatment of intracranial aneurysms. The objective of this systematic review was to compile device-related safety and effectiveness data. Methods The literature from January 1, 2013 to April 30, 2021 was searched for studies describing use of the FRED for intracranial aneurysm treatment irrespective of aneurysm location and morphology. The review included anterior and posterior circulation ruptured and unruptured saccular, fusiform or dissection, and blister aneurysms. MeSH terms related to “flow re-direction endoluminal device” and “FRED for aneurysms” were used. Data related to indication, complications, and rates of aneurysm occlusion were retrieved and analyzed. Results Twenty-two studies with 1729 intracranial aneurysms were included in this review. Overall reported morbidity was 3.9% (range 0–20%). Overall procedure-related mortality was 1.4% (range 0–6%). Complication rates fell into 5 categories: technical (3.6%), ischemic (3.8%), thrombotic or stenotic (6%), hemorrhagic (1.5%), and non-neurological (0.8%). The aneurysm occlusion rate between 0 and 3 months (reported in 11 studies) was 47.8%. The occlusion rate between 4 and 6 months (reported in 14 studies) was 73.8%. Occlusion rates continued to increase to 75.1% at 7–12 months (reported in 10 studies) and 86.6% for follow-up beyond 1 year (reported in 10 studies). Conclusion This review indicated that the FRED is a safe and effective for the treatment of intracranial aneurysms. Future studies should directly compare the FRED with other flow diverters for a better understanding of comparative safety and effectiveness among the different devices.


2019 ◽  
Vol 25 (6) ◽  
pp. 671-680 ◽  
Author(s):  
Junfan Chen ◽  
Yisen Zhang ◽  
Zhongbin Tian ◽  
Wenqiang Li ◽  
Qianqian Zhang ◽  
...  

Background Intracranial aneurysms are increasingly being treated by the placement of flow diverters; however, the factors affecting the outcome of aneurysms treated using flow diverters remain unclarified. Methods The present study investigated 94 aneurysms treated with pipeline embolisation device placement, and used a computational fluid dynamics method to explore the factors influencing the outcome of aneurysms. Results Seventy-six completely occluded aneurysms and 18 incompletely occluded aneurysms were analysed. Before treatment, inflow jets were found in 13 (72.2%) aneurysms in the incompletely occluded group and 34 (44.7%) in the completely occluded group ( P = 0.292). After deployment of the pipeline embolisation device, inflow jets remained in nine (50%) aneurysms in the incompletely occluded group and nine (11.8%) in the completely occluded group ( P = 0.001). In the incompletely occluded group, regions with inflow jets after treatment corresponded with the patent areas shown on follow-up digital subtraction angiography. The mean reduction ratios of velocity in the whole aneurysm and on the neck plane were lower in the incompletely occluded than in the completely occluded group ( P = 0.003; P = 0.017). Multivariate analysis revealed that the only independent risk factors for incomplete aneurysm occlusion were the reduction ratios of velocity (in the whole aneurysm, threshold 0.362, P = 0.005; on the neck plane, threshold 0.273, P = 0.015). Conclusions After pipeline embolisation device placement, reduction ratios of velocity in the whole aneurysm of less than 0.362 and on the neck plane of less than 0.273 are significantly associated with a greater risk of aneurysm incomplete occlusion. In addition, the persistence of inflow jets in aneurysms is associated with incomplete occlusion in the inflow jet area.


2019 ◽  
Vol 130 (2) ◽  
pp. 543-549 ◽  
Author(s):  
Felipe Padovani Trivelato ◽  
Marco Túlio Salles Rezende ◽  
Alexandre Cordeiro Ulhôa ◽  
Luis Henrique de Castro-Afonso ◽  
Guilherme Seizem Nakiri ◽  
...  

OBJECTIVEThe aim of this study was to compare the clinical and angiographic outcomes of intracranial aneurysms with and without branches arising from the sac after Pipeline embolization device (PED) treatment.METHODSThis retrospective 2-center comparative study included 116 patients with 157 aneurysms that were treated with PEDs. Aneurysms were divided into 2 groups: one group had branches arising from the sac and the other group did not. Study end points included total aneurysm occlusion assessed by angiography at 6 and 12 months, death or stroke, technical complications, in-stent stenosis, patency of covered branches, and transient ischemia.RESULTSOne hundred fifty-one aneurysms (96%) were located in the internal carotid artery. A branch arising from the sac was observed in 26 aneurysms. Complete occlusion was found in 120 of 156 aneurysms at 6 months (76.92% [95% CI 69.71%–82.84%]) and in 136 of 155 aneurysms at 12 months (87.74% [95% CI 81.28%–92.27%]). Total occlusion was more frequently observed in the group without a branch arising from the sac (84% vs 40% at 6 months, p < 0.001; 93.10% vs 60% at 1 year, p < 0.001). There were 4 (3.45% [95% CI 1.11%–9.12%]) cases of death or major stroke. Amaurosis fugax occurred in 3 patients. One patient experienced worsening of mass effect after treatment. No occlusion of branches arising from the aneurysm was observed. In-stent stenosis greater than 50% was observed in 1 case.CONCLUSIONSAneurysms treated with PEDs are less likely to be totally occluded if they have a branch arising from the sac than are aneurysms without these branches.


2015 ◽  
Vol 2015 ◽  
pp. 1-4
Author(s):  
Masashi Koide ◽  
Yuichi Tojo ◽  
Yoshihiro Hagiwara ◽  
Souichi Nakajima ◽  
Minoru Tanaka ◽  
...  

Pediatric septic arthritis is uncommon and has been traditionally treated by joint aspiration or open arthrotomy. There are some reports about arthroscopic surgery in pediatric septic arthritis of the knee, hip, and shoulder. However, there is no report for the case of elbow. We report a case of pediatric septic arthritis of elbow treated with arthroscopically with good clinical condition at 3-year follow-up. This paper is based on a report first published in Japanese (Tojo (2012)).


2014 ◽  
Vol 20 (4) ◽  
pp. 428-435 ◽  
Author(s):  
Willem Jan van Rooij ◽  
Ratna S Bechan ◽  
Jo P. Peluso ◽  
Menno Sluzewski

Flow diverter devices became available in our department in 2009. We considered treatment with flow diverters only in patients with aneurysms not suitable for surgery or conventional endovascular techniques. This paper presents our preliminary experience with flow diverters in a consecutive series of 550 endovascular aneurysm treatments. Between January 2009 and July 2013, 550 endovascular treatments for intracranial aneurysms were performed. Of these, 490 were first-time aneurysm treatments in 464 patients and 61 were additional treatments of previously coiled aneurysms in 51 patients. Endovascular treatments consisted of selective coiling in 445 (80.8%), stent-assisted coiling in 68 (12.4%), balloon-assisted coiling in 13 (2.4%), parent vessel occlusion in 12 (2.2%) and flow diverter treatment in 12 (2.2%). Eleven patients with 12 aneurysms were treated with flow diverters. Two patients had ruptured dissecting aneurysms. One patient with a basilar trunk aneurysm died of acute in stent thrombosis and another patient died of brain stem ischaemia at 32 months follow-up. One patient had ischaemia with permanent neurological deficit. Two aneurysms are still open at up to 30 months follow-up. Flow diversion was used in 2% of all endovascular treatments. Both our own poor results and the high complication rates reported in the literature have converted our initial enthusiasm to apprehension and hesitancy. The safety and efficacy profile of flow diversion should discourage the use of these devices in aneurysms that can be treated with other techniques.


2016 ◽  
Vol 126 (6) ◽  
pp. 1894-1898 ◽  
Author(s):  
Peter Kan ◽  
Visish M. Srinivasan ◽  
Nnenna Mbabuike ◽  
Rabih G. Tawk ◽  
Vin Shen Ban ◽  
...  

The Pipeline Embolization Device (PED) was approved for the treatment of intracranial aneurysms from the petrous to the superior hypophyseal segment of the internal carotid artery. However, since its approval, its use for treatment of intracranial aneurysms in other locations and non-sidewall aneurysms has grown tremendously. The authors report on a cohort of 15 patients with 16 cerebral aneurysms that incorporated an end vessel with no significant distal collaterals, which were treated with the PED. The cohort includes 7 posterior communicating artery aneurysms, 5 ophthalmic artery aneurysms, 1 superior cerebellar artery aneurysm, 1 anterior inferior cerebellar artery aneurysm, and 2 middle cerebral artery aneurysms. None of the aneurysms achieved significant occlusion at the last follow-up evaluation (mean 24 months). Based on these observations, the authors do not recommend the use of flow diverters for the treatment of this subset of cerebral aneurysms.


2019 ◽  
Vol 47 (6) ◽  
pp. E20 ◽  
Author(s):  
Brian M. Howard ◽  
Ranliang Hu ◽  
Jack W. Barrow ◽  
Daniel L. Barrow

Intracranial aneurysms confer the risk of subarachnoid hemorrhage (SAH), a potentially devastating condition, though most aneurysms will remain asymptomatic for the lifetime of the patient. Imaging is critical to all stages of patient care for those who harbor an unruptured intracranial aneurysm (UIA), including to establish the diagnosis, to determine therapeutic options, to undertake surveillance in patients who elect not to undergo treatment or whose aneurysm(s) portends such a low risk that treatment is not indicated, and to perform follow-up after treatment. Neuroimaging is equally as important in patients who suffer an SAH. DSA remains the reference standard for imaging of intracranial aneurysms due to its high spatial and temporal resolution. As noninvasive imaging technology, such as CTA and MRA, improves, the diagnostic accuracy of such tests continues to increasingly approximate that of DSA. In cases of angiographically negative SAH, imaging protocols are necessary not only for diagnosis but also to search for an initially occult vascular lesion, such as a thrombosed, ruptured aneurysm that might be detected in a delayed fashion. Given the crucial role of neuroimaging in all aspects of care for patients with UIAs and SAH, it is incumbent on those who care for these patients, including cerebrovascular neurosurgeons, interventional neurologists and neuroradiologists, and diagnostic radiologists and neurointensivists, to understand the role of imaging in this disease and how individual members of the multispecialty team use imaging to ensure best practices to deliver cutting-edge care to these often complex cases. This review expounds on the role of imaging in the management of UIAs and ruptured intracranial aneurysms and in the workup of angiographically negative subarachnoid hemorrhage.


2020 ◽  
Vol 71 (1) ◽  
pp. 185-191
Author(s):  
Tudor Parvanescu ◽  
Bogdan Buz ◽  
Diana Aurora Bordejevic ◽  
Florina Caruntu ◽  
Mihai Trofenciuc ◽  
...  

Anemia is frequently observed in heart failure (HF) patients. The aim of this prospective study was to assess if it is an independent predictor of outcome or a marker of a worse clinical condition in these patients. The study included 134 heart failure patients aged over 18 years. The patients were divided into two groups, according to the presence or absence of anemia at hospital admission. Anemia was defined as a hemoglobin concentration of less than 12 g/dl for women and less than 13 g/dl for men. The endpoints were: length of hospitalization, all cause-death during hospitalization, and all-cause death and HF rehospitalizations at 1 year. Anemia occurred in 33% of HF patients. The HF patients with anemia were significantly older, had more often ischemic etiology of heart failure and atrial fibrillation, chronic kidney disease and 3 or more comorbidities. The length of hospitalization was similar between the two groups. Deaths during hospitalization occurred in 13% of anemic and in 3% of the nonanemic patients (P=0.04). During the 1- year follow-up, 45% of the anemic vs. 28% of the nonanemic patients were rehospitalized due to aggravated HF (P=0.04), and 14% of the anemic vs 20% of the nonanemic patients died (P=0.38). Anemia was strongly predictive for in-hospital and 1- year all-cause deaths in univariate analysis, but not in multivariate analysis. Anemia seems more a marker of a worse clinical condition, rather than an independent risk factor in HF.


2020 ◽  
Vol 11 ◽  
Author(s):  
Qiuji Shao ◽  
Qiaowei Wu ◽  
Qiang Li ◽  
Tianxiao Li ◽  
Li Li ◽  
...  

Object: Follow-up evaluation of intracranial aneurysms treated by flow-diverting stents using MRI is challenging due to the presence of imaging artifacts. This study evaluated 3D T1-SPACE in combination with 3D-TOF sequence for follow-up evaluation of intracranial aneurysms treated with Pipeline embolization devices.Methods: Forty patients with 53 intracranial aneurysms who were treated with Pipeline Embolization Devices from October 2018 to July 2019 were enrolled in this study. All patients were evaluated for aneurysm occlusion and stent patency 4 to 7 months post-treatment using 3D T1-SPACE sequence, 3D-TOF MRA, and DSA examinations.Results: With regards to aneurysm occlusion, the intermodality (DSA and 3D-TOF MRA) agreement was good (κ = 0.755). The specificity of 3D-TOF MRA was 94.4% (34/36), the sensitivity was 76.5% (13/17), the total coincidence rate was 88.7% (47/53). With regards to the patency of the stented arteries after PED treatment, 3D T1-SPACE sequence was more accurate compared to 3D-TOF MRA (Z = −6.283, P &lt; 0.001), with a no-artifact rate of 95.7% (44/46).Conclusions: 3D T1-SPACE sequence provides better image quality and higher accuracy for evaluating stented parent arteries compared to TOF-MRA. 3D-TOF MRA may be valuable in the evaluation of aneurysm occlusion. The combination of these two modalities may be used for long-term follow-up of intracranial aneurysms treated with Pipeline Embolization Devices.