Nonuniform strain measurement in composite material based on optical frequency domain reflection

2016 ◽  
Vol 55 (6) ◽  
pp. 064103
Author(s):  
Huajun Li ◽  
Dongsheng Zhang ◽  
Litong Li ◽  
Mengqi Wu ◽  
Xiaoyan Wen
2013 ◽  
Vol 11 (10) ◽  
pp. 100603-100608 ◽  
Author(s):  
Fangdong Zhu Fangdong Zhu ◽  
Dongsheng Zhang Dongsheng Zhang ◽  
Peng Fan Peng Fan ◽  
Litong Li Litong Li ◽  
Yongxing Guo Yongxing Guo

Author(s):  
Tomonori Itoh ◽  
◽  
Hiromasa Otake ◽  
Takumi Kimura ◽  
Yoshiro Tsukiyama ◽  
...  

AbstractThe purpose of this study was to assess early and late vascular healing in response to bioresorbable-polymer sirolimus-eluting stents (BP-SESs) for the treatment of patients with ST-elevation myocardial infarction (STEMI) and stable coronary artery disease (CAD). A total of 106 patients with STEMI and 101 patients with stable-CAD were enrolled. Optical frequency-domain images were acquired at baseline, at 1- or 3-month follow-up, and at 12-month follow-up. In the STEMI and CAD cohorts, the percentage of uncovered struts (%US) was significantly and remarkably decreased during early two points and at 12-month (the STEMI cohort: 1-month: 18.75 ± 0.78%, 3-month: 10.19 ± 0.77%, 12-month: 1.80 ± 0.72%; p < 0.001, the CAD cohort: 1-month: 9.44 ± 0.78%, 3-month: 7.78 ± 0.78%, 12-month: 1.07 ± 0.73%; p < 0.001 respectively). The average peri-strut low-intensity area (PLIA) score in the STEMI cohort was significantly decreased during follow-up period (1.90 ± 1.14, 1.18 ± 1.25, and 1.01 ± 0.72; p ≤ 0.001), whereas the one in the CAD cohort was not significantly changed (0.89 ± 1.24, 0.67 ± 1.07, and 0.64 ± 0.72; p = 0.59). In comparison with both groups, differences of %US and PLIA score at early two points were almost disappeared or close at 12 months. The strut-coverage and healing processes in the early phase after BP-SES implantation were significantly improved in both cohorts, especially markedly in STEMI patients. At 1 year, qualitatively and quantitatively consistent neointimal coverage was achieved in both pathogenetic groups.


Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 670
Author(s):  
Wijayanti Dwi Astuti ◽  
Hiraku Matsukuma ◽  
Masaru Nakao ◽  
Kuangyi Li ◽  
Yuki Shimizu ◽  
...  

This paper proposes a new optical angle measurement method in the optical frequency domain based on second harmonic generation with a mode-locked femtosecond laser source by making use of the unique characteristic of the high peak power and wide spectral range of the femtosecond laser pulses. To get a wide measurable range of angle measurement, a theoretical calculation for several nonlinear optical crystals is performed. As a result, LiNbO3 crystal is employed in the proposed method. In the experiment, the validity of the use of a parabolic mirror is also demonstrated, where the chromatic aberration of the focusing beam caused the localization of second harmonic generation in our previous research. Moreover, an experimental demonstration is also carried out for the proposed angle measurement method. The measurable range of 10,000 arc-seconds is achieved.


Sign in / Sign up

Export Citation Format

Share Document