Time-resolved cathodoluminescence imaging of Mn2+ luminescence in Mn-doped CsPbCl3

Author(s):  
Rebecca Wai ◽  
Namrata Ramesh ◽  
Clarice Aiello ◽  
Jonathan Raybin ◽  
Steven Zeltmann ◽  
...  
2018 ◽  
Vol 185 (6) ◽  
Author(s):  
Wenjie Jing ◽  
Yuexiang Lu ◽  
Feiyang Wang ◽  
Liuying He ◽  
Jingwei Sun ◽  
...  
Keyword(s):  

2009 ◽  
Vol 80 (8) ◽  
Author(s):  
I. A. Akimov ◽  
R. I. Dzhioev ◽  
V. L. Korenev ◽  
Yu. G. Kusrayev ◽  
E. A. Zhukov ◽  
...  

2020 ◽  
Vol 11 (7) ◽  
pp. 2624-2629
Author(s):  
Rebecca B. Wai ◽  
Namrata Ramesh ◽  
Clarice D. Aiello ◽  
Jonathan G. Raybin ◽  
Steven E. Zeltmann ◽  
...  

2015 ◽  
Vol 74 ◽  
pp. 1053-1060 ◽  
Author(s):  
Dong Zhu ◽  
Wei Li ◽  
Hong-Mei Wen ◽  
Sheng Yu ◽  
Zhao-Yi Miao ◽  
...  

Author(s):  
Eva-Maria Mandelkow ◽  
Eckhard Mandelkow ◽  
Joan Bordas

When a solution of microtubule protein is changed from non-polymerising to polymerising conditions (e.g. by temperature jump or mixing with GTP) there is a series of structural transitions preceding microtubule growth. These have been detected by time-resolved X-ray scattering using synchrotron radiation, and they may be classified into pre-nucleation and nucleation events. X-ray patterns are good indicators for the average behavior of the particles in solution, but they are difficult to interpret unless additional information on their structure is available. We therefore studied the assembly process by electron microscopy under conditions approaching those of the X-ray experiment. There are two difficulties in the EM approach: One is that the particles important for assembly are usually small and not very regular and therefore tend to be overlooked. Secondly EM specimens require low concentrations which favor disassembly of the particles one wants to observe since there is a dynamic equilibrium between polymers and subunits.


Author(s):  
David C. Joy

Electron channeling patterns (ECP) were first found by Coates (1967) while observing a large bulk, single crystal of silicon in a scanning electron microscope. The geometric pattern visible was shown to be produced as a result of the changes in the angle of incidence, between the beam and the specimen surface normal, which occur when the sample is examined at low magnification (Booker, Shaw, Whelan and Hirsch 1967).A conventional electron diffraction pattern consists of an angularly resolved intensity distribution in space which may be directly viewed on a fluorescent screen or recorded on a photographic plate. An ECP, on the other hand, is produced as the result of changes in the signal collected by a suitable electron detector as the incidence angle is varied. If an integrating detector is used, or if the beam traverses the surface at a fixed angle, then no channeling contrast will be observed. The ECP is thus a time resolved electron diffraction effect. It can therefore be related to spatially resolved diffraction phenomena by an application of the concepts of reciprocity (Cowley 1969).


Author(s):  
T. Kizuka ◽  
N. Tanaka

Structure and stability of atomic clusters have been studied by time-resolved high-resolution electron microscopy (TRHREM). Typical examples are observations of structural fluctuation in gold (Au) clusters supported on silicon oxide films, graphtized carbon films and magnesium oxide (MgO) films. All the observations have been performed on the clusters consisted of single metal element. Structural stability of ceramics clusters, such as metal-oxide, metal-nitride and metal-carbide clusters, has not been observed by TRHREM although the clusters show anomalous structural and functional properties concerning to solid state physics and materials science.In the present study, the behavior of ceramic, magnesium oxide (MgO) clusters is for the first time observed by TRHREM at 1/60 s time resolution and at atomic resolution down to 0.2 nm.MgO and gold were subsequently deposited on sodium chloride (001) substrates. The specimens, single crystalline MgO films on which Au particles were dispersed were separated in distilled water and observed by using a 200-kV high-resolution electron microscope (JEOL, JEM2010) equipped with a high sensitive TV camera and a video tape recorder system.


Sign in / Sign up

Export Citation Format

Share Document