In vivo microscopic assessment of idiopathic pulmonary fibrosis using endobronchial optical coherence tomography: a prospective diagnostic study

Author(s):  
Sreyankar Nandy ◽  
Rebecca A. Israel ◽  
Ashok Muniappan ◽  
Angela Shih ◽  
Benjamin W. Roop ◽  
...  
2004 ◽  
Vol 171 (4S) ◽  
pp. 68-68 ◽  
Author(s):  
Markus D. Sachs ◽  
Dmitry Daniltchenko ◽  
Eva Lankenau ◽  
Frank Koenig ◽  
Gerion Huettmann ◽  
...  

Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 808
Author(s):  
Max Philipp Brinkmann ◽  
Nikolas Xavier Kibele ◽  
Michelle Prasuhn ◽  
Vinodh Kakkassery ◽  
Mario Damiano Toro ◽  
...  

Optical coherence tomography angiography (OCTA) is a non-invasive tool for imaging and quantifying the retinal and choroidal perfusion state in vivo. This study aimed to evaluate the acute effects of isometric and dynamic exercise on retinal and choroidal sublayer perfusion using OCTA. A pilot study was conducted on young, healthy participants, each of whom performed a specific isometric exercise on the first day and a dynamic exercise the day after. At baseline and immediately after the exercise, heart rate (HR), mean arterial pressure (MAP), superficial capillary plexus perfusion (SCPP), deep capillary plexus perfusion (DCPP), choriocapillaris perfusion (CCP), Sattlers’s layer perfusion (SLP), and Haller’s layer perfusion (HLP) were recorded. A total of 34 eyes of 34 subjects with a mean age of 32.35 ± 7.87 years were included. HR as well as MAP increased significantly after both types of exercise. Both SCPP and DCPP did not show any significant alteration due to isometric or dynamic exercise. After performing dynamic exercise, CCP, SLP, as well as HLP significantly increased. Changes in MAP correlated significantly with changes in HLP after the dynamic activity. OCTA-based analysis in healthy adults following physical activity demonstrated a constant retinal perfusion, supporting the theory of autoregulatory mechanisms. Dynamic exercise, as opposed to isometric activity, significantly changed choroidal perfusion. OCTA imaging may represent a novel and sensitive tool to expand the diagnostic spectrum in the field of sports medicine.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Jing Zhou ◽  
Yang Lin ◽  
Xiuhua Kang ◽  
Zhicheng Liu ◽  
Wei Zhang ◽  
...  

Abstract Background Previous reports have identified that human bone marrow mesenchymal stem cell-derived extracellular vesicles (BMSC-EVs) with their cargo microRNAs (miRNAs) are a promising therapeutic approach for the treatment of idiopathic pulmonary fibrosis (IPF). Therefore, we explored whether delivery of microRNA-186 (miR-186), a downregulated miRNA in IPF, by BMSC EVs could interfere with the progression of IPF in a murine model. Methods In a co-culture system, we assessed whether BMSC-EVs modulated the activation of fibroblasts. We established a mouse model of PF to evaluate the in vivo therapeutic effects of BMSC-EVs and determined miR-186 expression in BMSC-EVs by polymerase chain reaction. Using a loss-of-function approach, we examined how miR-186 delivered by BMSC-EVs affected fibroblasts. The putative relationship between miR-186 and SRY-related HMG box transcription factor 4 (SOX4) was tested using luciferase assay. Next, we investigated whether EV-miR-186 affected fibroblast activation and PF by targeting SOX4 and its downstream gene, Dickkopf-1 (DKK1). Results BMSC-EVs suppressed lung fibroblast activation and delayed IPF progression in mice. miR-186 was downregulated in IPF but enriched in the BMSC-EVs. miR-186 delivered by BMSC-EVs could suppress fibroblast activation. Furthermore, miR-186 reduced the expression of SOX4, a target gene of miR-186, and hence suppressed the expression of DKK1. Finally, EV-delivered miR-186 impaired fibroblast activation and alleviated PF via downregulation of SOX4 and DKK1. Conclusion In conclusion, miR-186 delivered by BMSC-EVs suppressed SOX4 and DKK1 expression, thereby blocking fibroblast activation and ameliorating IPF, thus presenting a novel therapeutic target for IPF.


2017 ◽  
Vol 51 (4) ◽  
pp. 410-418 ◽  
Author(s):  
Rupert S. Austin ◽  
Maisalamah Haji Taha ◽  
Frederic Festy ◽  
Richard Cook ◽  
Manoharan Andiappan ◽  
...  

Swept-source optical coherence tomography (SS-OCT) shows potential for the in vivo quantitative evaluation of micro-structural enamel surface phenomena occurring during early erosive demineralization. This randomized controlled single-blind cross-over clinical study aimed to evaluate the use of SS-OCT for detecting optical changes in the enamel of 30 healthy volunteers subjected to orange juice rinsing (erosive challenge) in comparison to mineral water rinsing (control), according to wiped and non-wiped enamel surface states. Participants were randomly allocated to 60 min of orange juice rinsing (pH 3.8) followed by 60 min of water rinsing (pH 6.7) and vice versa, with a 2-week wash-out period. In addition, the labial surfaces of the right or left maxillary incisors were wiped prior to SS-OCT imaging. An automated ImageJ algorithm was designed to analyse the back-scattered OCT signal intensity (D) after orange juice rinsing compared to after water rinsing. D was quantified as the OCT signal scattering from the 33 µm sub-surface enamel, normalised by the total OCT signal intensity entering the enamel. The back-scattered OCT signal intensity increased by 3.1% (95% CI 1.1-5.1%) in the wiped incisors and by 3.5% (95% CI 1.5-5.5%) in the unwiped incisors (p < 0.0001). Wiping reduced the back-scattered OCT signal intensity by 1.7% (95% CI -3.2 to -0.3%; p = 0.02) in comparison to the unwiped enamel surfaces for both rinsing solutions (p = 0.2). SS-OCT detected OCT signal changes in the superficial sub-surface enamel of maxillary central incisor teeth of healthy volunteers after orange juice rinsing.


1998 ◽  
Vol 4 (7) ◽  
pp. 861-865 ◽  
Author(s):  
Stephan A. Boppart ◽  
Brett E. Bouma ◽  
Costas Pitris ◽  
James F. Southern ◽  
Mark E. Brezinski ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4554
Author(s):  
Ralph-Alexandru Erdelyi ◽  
Virgil-Florin Duma ◽  
Cosmin Sinescu ◽  
George Mihai Dobre ◽  
Adrian Bradu ◽  
...  

The most common imaging technique for dental diagnoses and treatment monitoring is X-ray imaging, which evolved from the first intraoral radiographs to high-quality three-dimensional (3D) Cone Beam Computed Tomography (CBCT). Other imaging techniques have shown potential, such as Optical Coherence Tomography (OCT). We have recently reported on the boundaries of these two types of techniques, regarding. the dental fields where each one is more appropriate or where they should be both used. The aim of the present study is to explore the unique capabilities of the OCT technique to optimize X-ray units imaging (i.e., in terms of image resolution, radiation dose, or contrast). Two types of commercially available and widely used X-ray units are considered. To adjust their parameters, a protocol is developed to employ OCT images of dental conditions that are documented on high (i.e., less than 10 μm) resolution OCT images (both B-scans/cross sections and 3D reconstructions) but are hardly identified on the 200 to 75 μm resolution panoramic or CBCT radiographs. The optimized calibration of the X-ray unit includes choosing appropriate values for the anode voltage and current intensity of the X-ray tube, as well as the patient’s positioning, in order to reach the highest possible X-rays resolution at a radiation dose that is safe for the patient. The optimization protocol is developed in vitro on OCT images of extracted teeth and is further applied in vivo for each type of dental investigation. Optimized radiographic results are compared with un-optimized previously performed radiographs. Also, we show that OCT can permit a rigorous comparison between two (types of) X-ray units. In conclusion, high-quality dental images are possible using low radiation doses if an optimized protocol, developed using OCT, is applied for each type of dental investigation. Also, there are situations when the X-ray technology has drawbacks for dental diagnosis or treatment assessment. In such situations, OCT proves capable to provide qualitative images.


Sign in / Sign up

Export Citation Format

Share Document