Computer-aided 3D display system and its application in 3D vision test

1998 ◽  
Author(s):  
XiaoYun Shen ◽  
Lan Ma ◽  
Chunping Hou ◽  
Jiening Wang ◽  
Da Tang ◽  
...  
Author(s):  
Jana Busshoff ◽  
Rabi R. Datta ◽  
Thomas Bruns ◽  
Robert Kleinert ◽  
Bernd Morgenstern ◽  
...  

Abstract Background The use of 3D technique compared to high-resolution 2D-4K-display technique has been shown to optimize spatial orientation and surgical performance in laparoscopic surgery. Since women make up an increasing amount of medical students and surgeons, this study was designed to investigate whether one gender has a greater benefit from using a 3D compared to a 4K-display system. Methods In a randomized cross-over trial, the surgical performance of male and female medical students (MS), non-board certified surgeons (NBCS), and board certified surgeons (BCS) was compared using 3D- vs. 4K-display technique at a minimally invasive training parkour with multiple surgical tasks and repetitions. Results 128 participants (56 women, 72 men) were included. Overall parkour time in seconds was 3D vs. 4K for all women 770.7 ± 31.9 vs. 1068.1 ± 50.0 (p < 0.001) and all men 664.5 ± 19.9 vs. 889.7 ± 31.2 (p < 0.001). Regarding overall mistakes, participants tend to commit less mistakes while using the 3D-vision system, showing 10.2 ± 1.1 vs. 13.3 ± 1.3 (p = 0.005) for all women and 9.6 ± 0.7 vs. 12.2 ± 1.0 (p = 0.001) for all men. The benefit of using a 3D system, measured by the difference in seconds, was for women 297.3 ± 41.8 (27.84%) vs. 225.2 ± 23.3 (25.31%) for men (p = 0.005). This can be confirmed in the MS group with 327.6 ± 65.5 (35.82%) vs. 249.8 ± 33.7 (32.12%), p = 0.041 and in the NBCS group 359 ± 52.4 (28.25%) vs. 198.2 ± 54.2 (18.62%), p = 0.003. There was no significant difference in the BCS group. Conclusion 3D laparoscopic display technique optimizes surgical performance compared to the 2D-4K technique for both women and men. The greatest 3D benefit was found for women with less surgical experience. As a possible result of surgical education, this gender specific difference disappears with higher grade of experience. Using a 3D-vision system could facilitate surgical apprenticeship, especially for women.


Author(s):  
Ying Yuan ◽  
Xiaorui Wang ◽  
Yang Yang ◽  
Hang Yuan ◽  
Chao Zhang ◽  
...  

Abstract The full-chain system performance characterization is very important for the optimization design of an integral imaging three-dimensional (3D) display system. In this paper, the acquisition and display processes of 3D scene will be treated as a complete light field information transmission process. The full-chain performance characterization model of an integral imaging 3D display system is established, which uses the 3D voxel, the image depth, and the field of view of the reconstructed images as the 3D display quality evaluation indicators. Unlike most of the previous research results using the ideal integral imaging model, the proposed full-chain performance characterization model considering the diffraction effect and optical aberration of the microlens array, the sampling effect of the detector, 3D image data scaling, and the human visual system, can accurately describe the actual 3D light field transmission and convergence characteristics. The relationships between key parameters of an integral imaging 3D display system and the 3D display quality evaluation indicators are analyzed and discussed by the simulation experiment. The results will be helpful for the optimization design of a high-quality integral imaging 3D display system.


2020 ◽  
Vol 14 (1) ◽  
pp. 133-138
Author(s):  
Yoshihiro Sato ◽  
Shohei Yamaguchi ◽  
Shota Funaki ◽  
Atsutoshi Kurihara ◽  
Yuki Kumagai ◽  
...  

Remotely operated construction machines are used in cases where the operators are in danger, such as on steep slopes or contaminated sites. However, remote operation differs from what operators perceive during hands-on machine operation. Various studies have focused on improving work efficiency by employing remote control operation to reduce operator workload. In these studies, questionnaires were generally employed to evaluate the operator workload. However, the results obtained from the questionnaires varied depending on the physical conditions and the mood of the person on that day. It was therefore concluded that an accurate evaluation cannot be performed based on this method. Hence, in this study, the eye strain of machine operators was measured using an Auto Refractor/Keratometer. In particular, the ciliary muscle activities were measured before and after operating three display systems used for remote control of construction equipment. A quantitative evaluation was then conducted based on the eye strain data. The 2D display system exhibited low work accuracy and efficiency and resulted in significant eye strain. Although the 3D display system that required glasses exhibited high accuracy and efficiency, it resulted in significant eye strain. The 3D display system that did not require glasses demonstrated high accuracy and lower eye strain. From the results presented above, it was confirmed that the autostereoscopic 3D system is suitable for operators.


2006 ◽  
Author(s):  
Sung-Kyu Kim ◽  
Dong-Wook Kim ◽  
Min-Chul Park ◽  
Yong-Moo Kwon ◽  
Jung-Young Son
Keyword(s):  

2005 ◽  
Author(s):  
Seung-Cheol Kim ◽  
Jaw-Woong Moon ◽  
Dong-Hwi Lee ◽  
Kwang-Chul Son ◽  
Eun-Soo Kim

2005 ◽  
Author(s):  
Jae-Woong Moon ◽  
Dong-Whi Lee ◽  
Seung-Cheol Kim ◽  
Eun-Soo Kim
Keyword(s):  

2015 ◽  
Vol 11 (2) ◽  
pp. 121-128 ◽  
Author(s):  
Munekazu Munekazu ◽  
Hideaki Takada ◽  
Yuma Honda ◽  
Shiro Ozawa ◽  
Satoshi Mieda ◽  
...  
Keyword(s):  

Displays ◽  
2021 ◽  
pp. 102093
Author(s):  
Wu-Xiang Zhao ◽  
Han-Le Zhang ◽  
Qing-Lin Ji ◽  
Huan Deng ◽  
Da-Hai Li

2021 ◽  
Vol 41 (5) ◽  
pp. 0531001
Author(s):  
付秀华 Fu Xiuhua ◽  
郭宇怀 Guo Yuhuai ◽  
李爽 Li Shuang ◽  
张静 Zhang Jing ◽  
孙宇勃 Sun Yubo

Sign in / Sign up

Export Citation Format

Share Document