The Validity and Reliability of Knee Proprioception Measurement Performed With Inclinometer in Different Positions

2017 ◽  
Vol 26 (6) ◽  
Author(s):  
Sinem Suner-Keklik ◽  
Gamze Cobanoglu-Seven ◽  
Nihan Kafa ◽  
Mustafa Ugurlu ◽  
Nevin Atalay Guzel

Context: Proprioception is the basic element of the spontaneous control of movement, balance and joint stability. Therefore, it is necessary for the execution of walking and daily and sport activities. Loss of proprioception of the knee, which may cause a new injury, is important to evaluate the position sense of the joint during the rehabilitation period. However, the evaluation methods that are used are very expensive, complicated and nonportable, or the measuring method is difficult to implement. Objective: We demonstrated the validity and reliability of knee proprioception measurements performed in the open kinetic chain position and closed kinetic chain position with a dual inclinometer. Design: We assessed the validity and intratester reliability of a digital inclinometer for measuring the knee joint position sense in different positions. Setting: Clinical laboratory. Participants: We enrolled 22 participants (age = 21.8 ± 0.95 y, height = 172 ± 9.1 cm, weight = 64.9 ± 14 kg) into the study. Intervention: The same investigator used an inclinometer to take knee proprioception measurements in open and closed kinetic chain positions. Main Outcome Measures: The relative angular error was calculated by taking the arithmetic average of the difference between the target angle and reproduced angle and was the main outcome measure. Results: We found that the dynamometer-inclinometer had a moderate ICC value (ICC = 0.594, SEM = 1.60, P = .005), whereas inclinometer t1 vs inclinometer t2 (ICC = 0.778, SEM = 0.62, P < 0.001) and closed kinetic chain position t1 and closed kinetic chain position t2 (ICC = 0.888, SEM = 0.63, P < 0.001) had high ICC values. Conclusion: Knee proprioception measurements performed with a dual inclinometer were reliable in the closed kinetic chain position in healthy, sedentary individuals and were valid and reliable in the open kinetic chain position.

1999 ◽  
Vol 8 (3) ◽  
pp. 184-194 ◽  
Author(s):  
Mary E. Ubinger ◽  
William E. Prentice ◽  
Kevin M. Guskiewicz

When the upper extremity is injured, open kinetic chain (OKC) exercises are primarily used to increase strength and restore functional ability—the goals of rehabilitation. It is also imperative, however, that the receptors responsible for static and dynamic stabilization of the joint be trained. This can be done with closed kinetic chain (CKC) exercises. The purposes of this study were to investigate the effect of a 4-week CKC training program on the neuromuscular control of the upper extremity and to determine whether there was a significant difference between skill-dominant limb and nondominant limb stability indices. Thirty-two physically active participants (14 men, 18 women) were tested on the FASTEX 4 weeks apart. The training group's scores significantly improved, whereas the control group's scores remained the same. It was concluded that the CKC training significantly improved the training group's ability to remain stable. The results suggest that CKC training can increase the accuracy of joint position sense because of increased stimulation of the mechanoreceptors.


1998 ◽  
Vol 26 (4) ◽  
pp. 562-566 ◽  
Author(s):  
Trevor B. Birmingham ◽  
John F. Kramer ◽  
J. Tim Inglis ◽  
Colleen A. Mooney ◽  
Lisa J. Murray ◽  
...  

The primary objective of the present study was to compare the effect of a neoprene sleeve on knee joint position sense during a sitting open kinetic chain test and a supine closed kinetic chain test. Young (24 2 years old), healthy subjects (18 men and 18 women) performed knee joint angle replication tests during open kinetic chain knee extension (sitting) and closed kinetic chain leg press (supine with an axial load of 15% body weight) before and after application of a neoprene sleeve over the dominant knee. The improvement in ability to replicate joint angles after application of the sleeve (sleeve effect) was significantly less during the supine closed kinetic chain test (0.3° 1.4°) than during the sitting open kinetic chain test (1.2° 1.1°). The sleeve effect was inversely related to subjects' performance without the sleeve during both the sitting open kinetic chain and supine closed kinetic chain tests, suggesting that some people may derive greater benefit from the sleeve than others. Although the sleeve effects were small, particularly during the supine closed kinetic chain test, 72% of subjects felt that the sleeve improved their overall test performance. Future research is needed to establish the functional relevance of the small sleeve effects observed and to identify the characteristics of people who might derive greatest benefit from sleeve use.


2017 ◽  
Vol 26 (1) ◽  
Author(s):  
Natalia Romero-Franco ◽  
Juan Antonio Montaño-Munuera ◽  
Pedro Jiménez-Reyes

Context: Knee joint-position sense (JPS) is a key parameter for optimum performance in many sports but is frequently negatively affected by injuries and/or fatigue during training sessions. Although evaluation of JPS may provide key information to reduce the risk of injury, it often requires expensive and/or complex tools that make monitoring proprioceptive deterioration difficult. Objective: To analyze the validity and reliability of a digital inclinometer to measure knee JPS in a closed kinetic chain (CKC). Design: The validity and intertester and intratester reliability of a digital inclinometer for measuring knee JPS were assessed. Setting: Biomechanics laboratory. Participants: 10 athletes (5 men and 5 women; 26.2 ± 1.3 y, 71.7 ± 12.4 kg; 1.75 ± 0.09 m; 23.5 ± 3.9 kg/m2). Intervention: Knee JPS was measured in a CKC. Main Outcome Measures: Absolute angular error (AAE) of knee JPS in a CKC. Results: Intraclass correlation coefficient (ICC) and standard error of the mean (SEM) were calculated to determine the validity and reliability of the inclinometer. Data showed that the inclinometer had a high level of validity compared with an isokinetic dynamometer (ICC = 1.0, SEM = 1.39, P < .001), and there was very good intra- and intertester reliability for reading the inclinometer (ICC = 1.0, SEM = 0.85, P < .001). Compared with AutoCAD video analysis, inclinometer validity was very high (ICC = 0.980, SEM = 3.46, P < .001) for measuring AAE during knee JPS in a CKC. In addition, the intertester reliability of the inclinometer for obtaining AAE was very high (ICC = .994, SEM = 1.67, P < .001). Conclusion: The inclinometer provides a valid and reliable method for assessing knee JPS in a CKC. Health and sports professionals could take advantage of this tool to monitor proprioceptive deterioration in athletes.


2014 ◽  
Vol 13 (3) ◽  
pp. 331-339
Author(s):  
Fabio Navarro Cyrillo ◽  
Cristina Maria Nunes Cabral

Introduction: The evaluation of changes in joint position sense (JPS) of the knee may be crucial for the identification of disorders that could start during the development of patellofemoral pain syndrome (PFPS). Objective: To evaluate JPS of the knee in PFPS. Methods: Twenty nine women (15 healthy and 14 with PFPS) reproduced knee flexion angles of 45° and 60° during open kinetic chain exercises and of 45° during closed kinetic chain exercises. Results: The absolute error in the active reproduction of 45° in open kinetic chain exercises was significantly higher in the experimental group. There were significant differences in absolute and relative errors between the groups for active reproduction at 45° in open and closed kinetic chain exercises. Conclusions: This study suggests that PFPS alters JPS during active reproduction of the 45° angle in both open and closed kinetic chain exercises.


2019 ◽  
Vol 28 (4) ◽  
pp. 332-338 ◽  
Author(s):  
Natalia Romero-Franco ◽  
Juan Antonio Montaño-Munuera ◽  
Juan Carlos Fernández-Domínguez ◽  
Pedro Jiménez-Reyes

Context: New methods are being validated to easily evaluate the knee joint position sense (JPS) due to its role in the sports movement and the risk of injury. However, no studies to date have considered the open kinetic chain (OKC) technique, despite the biomechanical differences compared with closed kinetic chain movements. Objective: To analyze the validity and reliability of a digital inclinometer to measure the knee JPS in the OKC movement. Design: The validity and intertester and intratester reliability of a digital inclinometer for measuring knee JPS were evaluated. Setting: Sports research laboratory. Participants: A total of 18 athletes (11 males and 7 females; 28.4 [6.6] y; 71.9 [14.0] kg; 1.77 [0.09] m; 22.8 [3.2] kg/m2) voluntary participated in this study. Main Outcomes Measures: Absolute angular error (AAE), relative angular error (RAE), and variable angular error (VAE) of knee JPS in an OKC. Results: Intraclass correlation coefficient (ICC) and standard error of the mean (SEM) were calculated to determine the validity and reliability of the inclinometer. Data showed excellent validity of the inclinometer to obtain proprioceptive errors compared with the video analysis in JPS tasks (AAE: ICC = .981, SEM = 0.08; RAE: ICC = .974, SEM = 0.12; VAE: ICC = .973, SEM = 0.07). Intertester reliability was also excellent for all the proprioceptive errors (AAE: ICC = .967, SEM = 0.04; RAE: ICC = .974, SEM = 0.03; VAE: ICC = .939, SEM = 0.08). Similar results were obtained for intratester reliability (AAE: ICC = .861, SEM = 0.1; RAE: ICC = .894, SEM = 0.1; VAE: ICC = .700, SEM = 0.2). Conclusions: The digital inclinometer is a valid and reliable method to assess the knee JPS in OKC. Sport professionals may evaluate the knee JPS to monitor its deterioration during training or improvements throughout the rehabilitation process.


1996 ◽  
Vol 5 (1) ◽  
pp. 2-12 ◽  
Author(s):  
Lynn Snyder-Mackler

Closed kinetic chain exercise is a common component of lower extremity rehabilitation. It has virtually replaced open kinetic chain exercise in the treatment of some conditions. In this paper, anatomy and physiology as they relate to closed chain exercise are examined to elucidate its unique contributions to rehabilitation. Claims made about the specificity, functionality, and safety of closed kinetic chain exercise are discussed. Muscle action, the stretch–shortening cycle, joint position sense, and clinical cases are used to illustrate the distinct role of closed kinetic chain exercise in rehabilitation.


2005 ◽  
Vol 14 (4) ◽  
pp. 356-362 ◽  
Author(s):  
Lee Herrington

Context:Authors have investigated knee joint-position sense (JPS) in non-weight-bearing open kinetic chain (OKC) manner, but few have investigated JPS during closed kinetic chain (CKC) weight-bearing activities or the relationship between these two.Objective:To investigate the relationship between knee JPS during OKC and CKC maneuvers.Design:2-group (men and women) repeated-measures.Setting:Biomechanics laboratory.Participants:80 asymptomatic subjects.Interventions:None.Main Outcome Measure:Absolute error score of knee JPS during 2 conditions, a CKC squat or OKC knee-flexion maneuver.Results:Statistical analysis by 2-way ANOVA showed sex not to have a significant effect on error score (P= .475), but statistically significant differences between error scores occurred during the 2 tests (P= .0001), the CKC test producing lower error scores (group mean absolute error score OKC [5.6° ± 4.3°] and CKC [2.8° ± 2.4°]), with the absence of a correlation between scores of each test (r= .1).Conclusion:Testing JPS in a CKC scenario would seem appropriate—the ability is greatest (least errors), and conversely any deficits might be most obvious.


2021 ◽  
Vol 28 (10) ◽  
pp. 1-10
Author(s):  
Sanam Tavakkoli Oskouei ◽  
Roya Abazari ◽  
Mina Ahmadi Kahjoogh ◽  
Sakineh Goljaryan ◽  
Samane Zohrabi

Background/Aims Proprioception acuity is important in sports activities and stretching is widely used in warm-up programmes. The main objective of this study was to evaluate if a warm-up programme with and without stretching flexors and extensors muscles could affect knee joint position sense. Methods The effects of different stretching regimens on joint position sense were examined. A total of 12 semi-professional football players completed four warm-up sessions over 4 weeks: standard warm-up programme; standard warm-up programme with quadriceps stretching; standard warm-up programme with hamstring stretching; and standard warm-up programme with stretching of both quadriceps and hamstrings. Open kinetic chain knee joint position sense was estimated from the ability to reproduce the three target angles (20°, 45° and 60° knee flexion) in the dominant limb before and after the intervention. Results In the absolute angular error, there was a statistically significant three-way interaction between the warm-up programme, target angle and time (F (6, 54)=6.88, P=0.001). Findings of post-hoc analysis demonstrated that there was a statistically significant difference between the pre- and post-stretching of hamstrings for the target angles of 20° (4.70 vs 1.57, P=0.01), 45° (1.70 vs 4.50, P=0.02), and 60° (1.93 vs 4.20, P=0.02). In the relative angular error, interaction of time by the warm-up programme was significant (F (3, 27)=3.41, P=0.03). Conclusions The warm-up programme with static stretching of hamstrings had a negative effect on open kinetic chain knee joint position sense during the flexion to extension repositioning task, which may not only have a negative effect on performance of athletes as a part of warm-up exercises, but may also lead to further injuries.


1995 ◽  
Vol 4 (3) ◽  
pp. 165-171 ◽  
Author(s):  
Susan B. Andersen ◽  
Donna M. Terwilliger ◽  
Craig R. Denegar

The purpose of this study was to determine if a difference exists in the reproducibility of knee joint flexion angles in an open versus a closed kinetic chain. Thirty generally healthy subjects (12 males, 18 females; mean age 23.8 years) participated. Subjects actively reproduced small, medium, and large knee flexion angles (with target angles of 15°, 45°, and 75°, respectively) in an open and a closed kinetic chain while being videotaped. Goniometric measurements were taken from the videotape of initial and reproduced joint angles. Data were analyzed using ANOVA with repeated measures on kinetic chain test position and joint angle. Subjects more accurately reproduced knee flexion angles in a closed kinetic chain position. The main effect for angle and the interaction of angle and test position were nonsignificant. The results indicate that knee joint position is more accurately reproduced in closed kinetic chain. Closed kinetic chain testing is also a more functional assessment of joint position sense, and thus closed kinetic chain assessment of lower extremity joint position sense is recommended.


During the last 30 years, physiotherapy therapy and biokinetic rehabilitation have moved away from traditional isolated assessments to integrative functional screenings, viewing joint stability from a dynamic multi-planar perspective. An integrative functional final-phase knee rehabilitative assessment is needed to determine the quality of the rehabilitative progress; hence the authors’ proposed the squat as this assessment tool. The squat is a popular closed kinetic chain exercise that has been judiciously applied in the double stance closedkinetic-chain rehabilitation of knee injuries. However, it is postulated that the squat can extend as a final-phase-rehabilitative tool to assess whether the patient is ready to commence with open-kinetic chain-exercises.


Sign in / Sign up

Export Citation Format

Share Document